CoChat

Validated dispersive liquid–liquid microextraction for analysis of organophosphorous pesticides in water

Alves, Andreia Cristina Henriques, Gonçalves, Maria Margarida Pontes Boavida, Bernardo, Maria Manuel Serrano, Mendes, Benilde Simões · 2011 · Journal of Separation Science
Cited by 26

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography and mass spectrometry (GC‐MS) was applied to the determination of six organophosphorous pesticides (OPPs) in water samples. The analytes included in this study were prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction and dispersion solvents were tested for dispersive liquid–liquid microextraction of these analytes and the best results were obtained using chloroform as extraction solvent and 2‐propanol as dispersion solvent. Calibration curves of the analytes in water samples were constructed in the concentration range from 100 to 1100 ng/L for prophos, diazinon and methyl parathion and in the range from 100 to 1000 ng/L for chlorpyrifos methyl, fenchlorphos and chlorpyrifos. Limits of detection (LODs) were in the range of 1.5–9.1 ng/L and limits of quantification (LOQs) were in the range of 5.1–30.3 ng/L, below the maximum admissible level for drinking water. Relative standard deviations (RSDs) were between 6.5 and 10.1% in the concentration range of 100–1000 ng/L. The relative recoveries (%RRs) of tap, well and irrigation water samples fortified at 800 ng/L were in the range of 46.1–129.4%, with a larger matrix effect being detected in tap water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.201100111

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 26

Metadata

Authors
Alves, A. C. H., Gonçalves, M. M. P. B., Bernardo, M. M. S., & Mendes, B. S.
Venue
Journal of Separation Science
Publisher
Wiley
Published
2011-04-27
Volume
34
Issue
11
Pages
1326-1332
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2078167138
Cited by
26
References
10
FWCI
3.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validated dispersive liquid–liquid microextraction for analysis of organophosphorous pesticides in water. https://app.cochat.ai/papers/10.1002/jssc.201100111
The paper
Alves, A. C. H., Gonçalves, M. M. P. B., Bernardo, M. M. S., & Mendes, B. S. (2011). Validated dispersive liquid–liquid microextraction for analysis of organophosphorous pesticides in water. Journal of Separation Science. https://doi.org/10.1002/jssc.201100111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.