Automated hollow‐fiber liquid‐phase microextraction followed by liquid chromatography with mass spectrometry for the determination of benzodiazepine drugs in biological samples
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this study, two‐phase hollow‐fiber liquid‐phase microextraction and three‐phase hollow‐fiber liquid‐phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three‐phase hollow‐fiber liquid‐phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6–200 and 0.9–200 μg L−1 and the limits of detection were 0.2 and 0.3 μg L−1 for oxazepam and lorazepam, respectively. For two‐phase hollow fiber liquid‐phase microextraction, the calibration curves were found to be linear in the range of 1–200 and 1.5–200 μg L−1 and the limits of detection were 0.3 and 0.5 μg L−1 for oxazepam and lorazepam, respectively. In a urine sample, for three‐phase hollow‐fiber‐based liquid‐phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2–4.5% and preconcentration factors in the range of 70–180 were obtained for oxazepam and lorazepam, respectively. Also for the two‐phase hollow‐fiber liquid‐phase microextraction, preconcentration factors in the range of 101–257 were obtained for oxazepam and lorazepam, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Before the injection—Modern methods of sample preparation for separation techniques
Smith, R. M. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00511-9 · Cited by 503
Rezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.091 · Cited by 336
Self-citationTao, Y., Liu, J.-F., Wang, T., & Jiang, G.-B. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.094 · Cited by 66
Taheri, S., Jalali, F., Fattahi, N., & Bahrami, G. (2015) · Journal of Separation Science · doi:10.1002/jssc.201401115 · Cited by 42
Cited by
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Khataei, M. M., Yamini, Y., Nazaripour, A., & Karimi, M. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.068 · Cited by 113
Self-citationTorbati, M., Farajzadeh, M. A., Mogaddam, M. R. A., & Torbati, M. (2019) · Journal of Separation Science · doi:10.1002/jssc.201801016 · Cited by 67
Metadata
- Authors
- Nazaripour, A., Yamini, Y., Ebrahimpour, B., & Fasihi, J.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2016-06-07
- Volume
- 39
- Issue
- 13
- Pages
- 2595-2603
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2346527497
- Cited by
- 35
- References
- 5
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.