Cited by 336Analytical chemistry methods developmentAnalytical Chemistry and ChromatographyEffects and risks of endocrine disrupting chemicals

Dispersive liquid–liquid microextraction combined with high-performance liquid chromatography-UV detection as a very simple, rapid and sensitive method for the determination of bisphenol A in water samples

Rezaee, Mohammad, Yamini, Yadollah, Shariati, Shahab, Esrafili, Ali, Shamsipur, Mojtaba·2009·Journal of Chromatography A

Abstract

Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied for the extraction and determination of bisphenol A (BPA) in water samples. An appropriate mixture of acetone (disperser solvent) and chloroform (extraction solvent) was injected rapidly into a water sample containing BPA. After extraction, sedimented phase was analyzed by HPLC-UV. Under the optimum conditions (extractant solvent: 142 microL of chloroform, disperser solvent: 2.0 mL of acetone, and without salt addition), the calibration graph was linear in the range of 0.5-100 microgL(-1) with the detection limit of 0.07 microgL(-1) for BPA. The relative standard deviation (RSD, n=5) for the extraction and determination of 100 microgL(-1) of BPA in the aqueous samples was 6.0%. The results showed that DLLME is a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of BPA in water samples and suitable results were obtained.

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2008.12.091

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M.
Affiliations
  • Tarbiat Modares University (IR)
  • Islamic Azad University Rasht Branch (IR)
  • Razi University (IR)
Corresponding author
Yamini, Yadollah
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2009-02
Volume
1216
Issue
9
Pages
1511-1514
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2046364307
Cited by
336
References
2
Citations by year
2026: 7 · 2025: 4 · 2024: 13 · 2023: 15 · 2022: 12 · 2021: 17 · 2020: 14 · 2019: 23 · 2018: 22 · 2017: 19 · 2016: 32 · 2015: 18 · 2014: 22 · 2013: 28 · 2012: 31
FWCI
28.81
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Funders
Iran National Science Foundation
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Effects and risks of endocrine disrupting chemicals
Keywords
bisphenol A, dispersive liquid-liquid microextraction, water analysis, trace analysis, chloroform extraction, HPLC-UV detection, endocrine disruptors
MeSH terms
Acetone, Bisphenol A Compounds, Benzhydryl Compounds, Chloroform, Chromatography, High Pressure Liquid, Data Interpretation, Statistical, Chemical Fractionation, Fresh Water, Phenols, Sensitivity and Specificity, Sodium Chloride, Time Factors, Water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review