Three-phase hollow-fiber liquid-phase microextraction based on deep eutectic solvent as acceptor phase for extraction and preconcentration of main active compounds in a traditional Chinese medicinal formula
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A three-phase hollow-fiber liquid-phase microextraction based on deep eutectic solvent as acceptor phase was developed and coupled with high-performance capillary electrophoresis for the simultaneous extraction, enrichment, and determination of main active compounds (hesperidin, honokiol, shikonin, magnolol, emodin, and β,β'-dimethylacrylshikonin) in a traditional Chinese medicinal formula. In this procedure, two hollow fibers, impregnated with n-heptanol/n-nonanol (7:3, v/v) mixture in wall pores as the extraction phase and a combination (9:1, v/v) of methyltrioctylammonium chloride/glycerol (1:3, n/n) and methanol in lumen as the acceptor phase, were immersed in the aqueous sample phase. The target analytes in the sample solution were first extracted through the organic phase, and further back-extracted to the acceptor phase during the stirring process. Important extraction parameters such as types and composition of extraction solvent and deep eutectic solvent, sample phase pH, stirring rate, and extraction time were investigated and optimized. Under the optimal conditions, detection limits were 0.3-0.8 ng/mL with enrichment factors of 6-114 for the analytes and linearities of 0.001-13 μg/mL (r 2 ≥ 0.9901). The developed method was successfully applied to the simultaneous extraction and concentration of the main active compounds in a formula of Zi-Cao-Cheng-Qi decoction with the major advantages of convenience, effectiveness, and environmentally friendliness.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The detection limits of the proposed method were 0.3–0.8 ng/mL, while the higher extraction efficiency and absence of salt were considered as advantages in comparison with 2p-HF-LPME [90].”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [90]
Citations
Cites
Abbott, A. P., Capper, G., Davies, D. L., Rasheed, R. K., & Tambyrajah, V. (2003) · Chemical Communications · doi:10.1039/b210714g · Cited by 5,738
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Extraction techniques with deep eutectic solvents
Cunha, S. C., & Fernandes, J. O. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.001 · Cited by 760
Application of deep eutectic solvents in analytical chemistry. A review
Shishov, A., Bulatov, A., Locatelli, M., Carradori, S., & Andruch, V. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.07.015 · Cited by 617
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Ionic deep eutectic solvents for the extraction and separation of natural products
Huang, J., Guo, X., Xu, T., Fan, L., Zhou, X., & Wu, S. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.03.046 · Cited by 221
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182
Wang, H., Hu, L., Liu, X., Yin, S., Lu, R., Zhang, S., Zhou, W., & Gao, H. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.073 · Cited by 118
Khataei, M. M., Yamini, Y., Nazaripour, A., & Karimi, M. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.068 · Cited by 113
Tang, B., Bi, W., Zhang, H., & Row, K. H. (2014) · Chromatographia · doi:10.1007/s10337-013-2607-3 · Cited by 105
Applications of liquid-phase microextraction techniques in natural product analysis: A review
Yan, Y., Chen, X., Hu, S., & Bai, X. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.09.068 · Cited by 96
Self-citationGhambarian, M., Yamini, Y., Esrafili, A., Yazdanfar, N., & Moradi, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.07.013 · Cited by 68
Rajabi, M., Ghassab, N., Hemmati, M., & Asghari, A. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.11.008 · Cited by 49
Alavi, L., Seidi, S., Jabbari, A., & Baheri, T. (2017) · New Journal of Chemistry · doi:10.1039/c7nj00922d · Cited by 37
Li, M., Chen, X., Hu, S., Wang, R., Peng, X., & Bai, X. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.11.046 · Cited by 31
Self-citationNatural product applications of liquid-phase microextraction
Hu, S., Chen, X., Wang, R.-Q., Yang, L., & Bai, X.-H. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.006 · Cited by 30
Self-citationLi, M., Hu, S., Chen, X., & Bai, X. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700481 · Cited by 26
Self-citationLi, M., Hu, S., Chen, X., Wang, R., & Bai, X. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.10.026 · Cited by 13
Self-citation
Research works printed but not linked: 1
- Wang K. Zheng‐Zhi‐zhun‐Sheng China Medical Science and Technology Press Beijing 1997.
Cited by
Freitas, L. C., Barbosa, J. R., da Costa, A. L. C., Bezerra, F. W. F., Pinto, R. H. H., & Carvalho Junior, R. N. D. (2021) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2021.105466 · Cited by 328
Kanu, A. B. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462444 · Cited by 271
Farooq, M. Q., Abbasi, N. M., & Anderson, J. L. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461613 · Cited by 222
Deep eutectic solvents in liquid-phase microextraction: Contribution to green chemistry
Santos, L. B., de Assis, R. D. S., Barreto, J. A., Bezerra, M. A., Novaes, C. G., & Lemos, V. A. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116478 · Cited by 162
Serna-Vázquez, J., Ahmad, M. Z., Boczkaj, G., & Castro-Muñoz, R. (2021) · Molecules · doi:10.3390/molecules26165037 · Cited by 140
Metadata
- Authors
- Xue, J., Wang, R., Chen, X., Hu, S., & Bai, X.
- Affiliations
- Shanxi Medical University (CN)
- School of Pharmacy Shanxi Medical University Taiyuan P. R. China
- Corresponding author
- Hu, Shuang
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2019-05-15
- Volume
- 42
- Issue
- 13
- Pages
- 2239-2246
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2942341534
- Cited by
- 38
- References
- 18
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 9 · 2020: 11 · 2019: 2
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Science Foundation of Shanxi Province (201701D121145)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Health Sciences › Medicine › Complementary and alternative medicine › Traditional Chinese Medicine Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- deep eutectic solvents, traditional Chinese medicine, hesperidin, honokiol, shikonin, magnolol, emodin, preconcentration, capillary electrophoresis
- MeSH terms
- Drugs, Chinese Herbal, Hydrogen-Ion Concentration, Medicine, Chinese Traditional, Sodium Chloride, Solvents, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.