Fusion motion capture: A prototype system using inertial measurement units and GPS for the biomechanical analysis of ski racing
The DOI matches its OpenAlex record.
Abstract
In this pilot study fusion motion capture (FMC) has been used to capture 3‐D kinetics and kinematics of alpine ski racing. The new technology has overcome the technological difficulties associated with athlete performance monitoring in an alpine environment. FMC is a general term to describe motion capture when several different streams of data are fused to measure athlete motion. In this article inertial measurement units (IMU), global positioning system (GPS) pressure sensitive insoles, video and theodolite measurements have been combined. The core of the FMC is the fusion of IMU and GPS data. IMU may contain accelerometers, gyroscopes, magnetometers and a thermometer, and they track local orientation and acceleration of each limb segment of interest. GPS data are fused with local acceleration data to track the global trajectory of the athlete. Fusion integration algorithms designed by the authors [1] were used to improve the accuracy of the independent Kalman filter solutions provided by the vendors of both the GPS and IMU. The GPS accuracy was improved from a dilution of precision of ±5m (meaning 50% of the measurements will be within 5 m of the true value) to a maximum error of ±1.5 m over the race course, while the IMU orientation error was reduced from over 20° to less than 5°. The reader is invited to assess the validity of these results by comparing videos of the motion to the fusion motion capture output in the electronic version of this manuscript. Accuracy in laboratory situations has been validated, [2,3] but because such systems are becoming more popular, this system needs to be validated on the snow. As more accurate dual frequency GPS systems become less expensive this type of system will become more accurate and affordable. A biomechanical analysis was undertaken of a New Zealand Alpine Ski Racing Team member negotiating a 10‐gate giant slalom course over 300 m in length. The abundant data in the results were used to create new tools for measuring alpine ski racing technique, such as colour‐coded force vector analysis. The new parameters introduced in this article, such as effective inclination and ground reaction force power, are independent of the stylistic constraints often imposed by the coach or athlete. Two ski runs have been compared. Although the difference between the two run times was only 0.14 s or 1%, FMC and force vector analysis were able to pick up the subtle changes in technique between the two runs. It is believed the analyses will provide useful design parameters to ski equipment engineers and will allow athlete feedback through augmented reality animations about variables, including limb dynamics, centre of mass (CoM) trajectory, CoM velocity, and external forces. In‐depth analysis of the changes in net joint torques with changes in athlete posture may be useful for coaching athlete specific technique changes to improve performance and reduce injury potential. In addition, it is possible to extract key performance indicators about the athlete's physical and physiological limits, such as the mean coefficient of wind drag and the maximum inclination angle while turning, which may be used to optimise race strategies. There are tentative plans to use an improved version of a similar motion capture system to analyse forerunners on the FIS world cup race circuit. The purpose is to reduce knee anterior cruciate ligament (ACL) injuries and provide a visual biomechanical analysis of an athlete running the course to enhance the experience of the television audience. In alpine ski racing, forerunners ski the course before the first athlete to set ski tracks through the gates and check the safety of the course.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
Blair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
A Mobile Motion Capture System Based on Inertial Sensors and Smart Shoes
Jung, P.-G., Oh, S., Lim, G., & Kong, K. (2014) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.4025207 · Cited by 44
Metadata
- Authors
- Brodie, M. A. D., Walmsley, A., & Page, W. H.
- Venue
- Sports Technology
- Publisher
- Taylor & Francis
- Published
- 2008-01-01
- Volume
- 1
- Issue
- 1
- Pages
- 17-28
- ISSN
- 1934-6182 (ISSN-L)
- OpenAlex
- W2122192618
- Cited by
- 189
- References
- 0
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fusion motion capture: A prototype system using inertial measurement units and GPS for the biomechanical analysis of ski racing. https://app.cochat.ai/papers/10.1002/jst.6
- The paper
- Brodie, M. A. D., Walmsley, A., & Page, W. H. (2008). Fusion motion capture: A prototype system using inertial measurement units and GPS for the biomechanical analysis of ski racing. Sports Technology. https://doi.org/10.1002/jst.6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.