Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies
Open accessAbstract
The accuracy and repeatability of an inertial measurement unit (IMU) system for directly measuring trunk angular displacement and upper arm elevation were evaluated over eight hours (i) in comparison to a gold standard, optical motion capture (OMC) system in a laboratory setting, and (ii) during a field-based assessment of dairy parlour work. Sample-to-sample root mean square differences between the IMU and OMC system ranged from 4.1° to 6.6° for the trunk and 7.2°-12.1° for the upper arm depending on the processing method. Estimates of mean angular displacement and angular displacement variation (difference between the 90th and 10th percentiles of angular displacement) were observed to change <4.5° on average in the laboratory and <1.5° on average in the field per eight hours of data collection. Results suggest the IMU system may serve as an acceptable instrument for directly measuring trunk and upper arm postures in field-based occupational exposure assessment studies with long sampling durations. Practitioner Summary: Few studies have evaluated inertial measurement unit (IMU) systems in the field or over long sampling durations. Results of this study indicate that the IMU system evaluated has reasonably good accuracy and repeatability for use in a field setting over a long sampling duration.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pelvis RMSE and correlation coefficients varied from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity.
“RMSE and correlation coefficients varied respectively from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity [30,36,38,41,42,52].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 73 · Cited by 96
- Authors
- Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I.
- Affiliations
- Auburn University (US)
- University of Iowa (US)
- The University of Texas at San Antonio (US)
- ,
- Corresponding author
- Schall, Mark C.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2015-10-07
- Volume
- 59
- Issue
- 4
- Pages
- 591-602
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- PMC
- PMC9469634
- OpenAlex
- W1918408772
- Cited by
- 96
- References
- 73
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 5 · 2023: 9 · 2022: 8 · 2021: 10 · 2020: 11 · 2019: 10 · 2018: 10 · 2017: 10 · 2016: 9 · 2015: 2
- FWCI
- 16.90
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Ergonomics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute for Occupational Safety and Health (2U54OH008085-08, 5T42OH008491-08, 5U54OH007548-13A)
- Topics
- Social Sciences › Psychology › Social Psychology › Ergonomics and Musculoskeletal Disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety in Workplaces
- Keywords
- inertial measurement unit, measurement accuracy, repeatability, occupational exposure assessment, optical motion capture comparison
- MeSH terms
- Adult, Arm, Biomechanical Phenomena, Dairying, Humans, Ergonomics, Male, Movement, Posture, Reproducibility of Results, Occupational Exposure, Young Adult, Torso
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review