CoChat

Three‐dimensional computed tomography in obstructive sleep apneics treated by maxillomandibular advancement

Lin, Cheng‐Hui, Liao, Yu‐Fang, Chen, Ning‐Hung, Lo, Lun‐Jou, Chen, Yu‐Ray · 2011 · The Laryngoscope
Cited by 46

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objectives/Hypothesis: The goal of this study was to understand the changes to the head and neck musculoskeleton and the pharyngeal airway after surgery. We tested the correlation between the changes in the skeleton and pharyngeal airway and the apnea‐hypopnea index (AHI). Study Design: Prospective, noncontrolled study. Methods: In a pilot study, 12 consecutive subjects (3 women, body mass index: 22.4 Kg/m 2 ± 2.7, AHI: 35.9/sec ± 18.0) with Class II dentoskeletal malocclusion and high mandibular plane underwent segmental maxillomandibular rotational advancement (SMMRA). Subjects underwent overnight polysomnography and three‐dimensional computed tomography scanning of the head and neck before and 3 months after surgery. Linear, angular, and area measurements were obtained from skeletal images placed in the Frankfort horizontal position and from horizontal cross‐sectional tomograms derived from the upright pharyngeal airway. Skeletal movements, dimensional changes of the airway, and correlations between measurements and AHI were calculated. A linear regression model was generated using significant bivariate correlations. Results: The AHI was significantly reduced to 4.6/sec ± 4.1 with improvement in the nadir oxygen saturation from 83.0% ± 7.2 to 90.6% ± 3.6 after SMMRA. Following skeletal advancement, the hyoid bone was advanced and elevated by 7.5 mm ± 2.9 and 6.7 mm ± 5.5, respectively; the cervical spine was rotated forward by 4.6° ± 2.8; and the airway length was shortened by 6.8 mm ± 4.0 (all P < .01). Variable improvement of airway dimensions was noted at each horizontal level. A quadratic regression model was derived using the measurements of the Sella‐Nasion‐B point angle and AHI (Rsq = 0.557, sig = 0.000). Conclusions: Dimensions of pharyngeal airway were correlated with dimensions of craniofacial skeleton. Sella‐Nasion‐B point angle could be used as a guidance in achieving normalized AHI after surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.21813

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Lin, C., Liao, Y., Chen, N., Lo, L., & Chen, Y.
Venue
The Laryngoscope
Publisher
Wiley
Published
2011-05-06
Volume
121
Issue
6
Pages
1336-1347
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2028349683
Cited by
46
References
10
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.