Use of lean sigma principles in a tertiary care otolaryngology clinic to improve efficiency
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives/Hypothesis: To apply Lean Sigma, a quality‐improvement strategy supported by tactical tools to eliminate waste and reduce variation, to improve efficiency of patient flow in a large tertiary otolaryngology clinic. The project goals were to decrease overall lead time from patient arrival to start of interaction with care provider, improve on‐time starts of patient visits, and decrease excess staff/patient motion. Study Design: Prospective observational study. Methods: Patient flow was mapped through the clinic, including preregistration processes. A time‐stamp observation study was performed on 188 patient visits over 5 days. Using Lean Sigma principles, time stamps were analyzed to identify patient flow constraints and areas for potential interventions. Interventions were evaluated and adjusted based on feedback from shareholders: removal of bottlenecks in clinic flow, elimination of non–value added registration staff tasks, and alignment of staff hours to accommodate times of high patient census. A postintervention time observation study of 141 patients was performed 5 months later. Results: Patient lead time from clinic arrival to exam start time decreased by 12.2% on average (P = .042). On‐time starts for patient exams improved by 34% (χ 2 = 16.091, P < .001). Excess patient motion was reduced by 74 feet per patient, which represents a 34% reduction in motion per visit. Conclusions: Use of Lean Sigma principles in a large tertiary otolaryngology clinic led to decreased patient wait time and significant improvements in on‐time patient exam start time. Process mapping, engagement of leadership and staff, and elimination of non–value added steps or processes were key to improvement. Level of Evidence: 4. Laryngoscope, 123:2643–2648, 2013
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of Lean in the emergency department: a case series of 4 hospitals
Dickson, E. W., Anguelov, Z., Vetterick, D., Eller, A., & Singh, S. (2009) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2009.03.024 · Cited by 244 · cited 1×
“The use of Lean in four emergency departments resulted in a decrease in stay in three of the four departments.(7) Similarly, Six Sigma principles were applied to a resident hospital–based obstetrics and gynecology clinic to improve patient access and wait times in clinic.”
Method
Cited by
Process mapping in healthcare: a systematic review
Antonacci, G., Lennox, L., Barlow, J., Evans, L., & Reed, J. (2021) · BMC Health Services Research · doi:10.1186/s12913-021-06254-1 · Cited by 178
Effects of Lean Healthcare on Patient Flow: A Systematic Review
Tlapa, D., Zepeda-Lugo, C. A., Tortorella, G. L., Baez-Lopez, Y. A., Limon-Romero, J., Alvarado-Iniesta, A., & Rodriguez-Borbon, M. I. (2020) · Value in Health · doi:10.1016/j.jval.2019.11.002 · Cited by 175
Hultman, C. S., Kim, S., Lee, C. N., Wu, C., Dodge, B., Hultman, C. E., Roach, S. T., & Halvorson, E. G. (2016) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000000786 · Cited by 33
Roberts, R. J., Wilson, A. E., & Quezado, Z. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001621 · Cited by 27
Metadata
- Authors
- Lin, S. Y., Gavney, D., Ishman, S. L., & Cady‐Reh, J.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2013-03-25
- Volume
- 123
- Issue
- 11
- Pages
- 2643-2648
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2163716014
- Cited by
- 54
- References
- 1
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.