Targeted hypoglossal nerve stimulation for the treatment of obstructive sleep apnea: Six‐month results
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Objectives/Hypothesis: This feasibility study was designed to show the preliminary safety and efficacy of targeted hypoglossal neurostimulation (THN), and to identify baseline predictors of successful therapy. Study Design: Open‐label, prospective, multicenter, single‐arm cohort study, conducted at seven centers in the U.S.A. and Europe. Methods: Forty‐six participants with moderate to severe obstructive sleep apnea (OSA), failing or intolerant of continuous positive airway pressure, were implanted. Primary (Apnea‐Hypopnea Index [AHI], Oxygen Desaturation Index [ODI]) and secondary (Arousal Index, Epworth Sleepiness Scale Index, Sleep Apnea Quality of Life Index) outcomes were measured at baseline and compared at 6 months. Data were analyzed to identify participant characteristics that would predict success with therapy. Results: Sixty‐seven adverse events (AEs) were observed among 36 participants; most of the AEs were related to the implant procedure and resolved without sequelae; one device replacement was necessary. Forty‐three participants showed significant (P < .01) decreases in both AHI and ODI at 6 months; 35% (15 of 43) met criteria for AHI responders and 40% (17 of 43) for ODI responders. Significant improvement was observed in all the secondary endpoints. Predictors‐of‐success selection criteria were identified as baseline AHI < 65/hr, baseline apnea index ≤ 30, baseline body mass index < 35, and <15 events/hr of SpO 2 decrease > 10%. Seven participants met these criteria; 86% (6 of 7) were AHI responders and 86% (6 of 7) were ODI responders, indicating that THN therapy can be efficacious in a carefully selected population of OSA patients. Conclusions: This feasibility study suggests that THN therapy is likely to be safe and effective in selected patients. Level of Evidence: 2b Laryngoscope, 126:2618–2623, 2016
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Obstructive Sleep Apnea as a Risk Factor for Stroke and Death
Yaggi, H. K., Concato, J., Kernan, W. N., Lichtman, J. H., Brass, L. M., & Mohsenin, V. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043104 · Cited by 3,004
Obstructive sleep apnoea and its cardiovascular consequences
Bradley, T. D., & Floras, J. S. (2009) · The Lancet · doi:10.1016/s0140-6736(08)61622-0 · Cited by 1,385
Sher, A. E., Schechtman, K. B., & Piccirillo, J. F. (1996) · Sleep · doi:10.1093/sleep/19.2.156 · Cited by 1,335
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299
Self-citationCaples, S. M., Rowley, J. A., Prinsell, J. R., Pallanch, J. F., Elamin, M. B., Katz, S. G., & Harwick, J. D. (2010) · Sleep · doi:10.1093/sleep/33.10.1396 · Cited by 541
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Functional electrical stimulation and respiration during sleep
Decker, M. J., Haaga, J., Arnold, J. L., Atzberger, D., & Strohl, K. P. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.3.1053 · Cited by 91
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationHypoglossal nerve stimulation long-term clinical outcomes: a systematic review and meta-analysis
Costantino, A., Rinaldi, V., Moffa, A., Luccarelli, V., Bressi, F., Cassano, M., Casale, M., & Baptista, P. (2020) · Sleep and Breathing · doi:10.1007/s11325-019-01923-2 · Cited by 121
Selective upper airway stimulation for obstructive sleep apnea: a single center clinical experience
Heiser, C., Knopf, A., Bas, M., Gahleitner, C., & Hofauer, B. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-016-4297-6 · Cited by 93
Heiser, C., Maurer, J. T., Hofauer, B., Sommer, J. U., Seitz, A., & Steffen, A. (2017) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599816683378 · Cited by 91
Self-citation
Metadata
- Authors
- Friedman, M., Jacobowitz, O., Hwang, M. S., Bergler, W., Fietze, I., Rombaux, P., Mwenge, G. B., Yalamanchali, S., Campana, J., & Maurer, J. T.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2016-03-24
- Volume
- 126
- Issue
- 11
- Pages
- 2618-2623
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2304427762
- Cited by
- 112
- References
- 7
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.