Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia

Open access
Giraldo‐Cadavid, Luis Fernando, Leal‐Leaño, Lorena Renata, Leon‐Basantes, Guillermo Alfredo, Bastidas, Alirio Rodrigo, Garcia, Rafael, Ovalle, Sergio, Abondano‐Garavito, Jorge E. · 2017 · The Laryngoscope

Abstract

Objectives: A systematic review and meta‐analysis of the literature was conducted to compare the accuracy with which flexible endoscopic evaluation of swallowing (FEES) and videofluoroscopic swallowing study (VFSS) assessed oropharyngeal dysphagia in adults. Data Sources: PubMed, Embase, and the Latin American and Caribbean Health Sciences Literature (LILACS) database. Methods: A review of published studies was conducted in parallel by two groups of researchers. We evaluated the methodological quality, homogeneity, threshold effect, and publication bias. The results are presented as originally published, then with each test compared against the other as a reference and both compared against a composite reference standard, and then pooled using a random effects model. Software use consisted of Meta‐DiSc and SPSS. Results: The search yielded 5,697 articles. Fifty‐two articles were reviewed in full text, and six articles were included in the meta‐analysis. FEES showed greater sensitivity than VFSS for aspiration (0.88 vs. 0.77; P = .03), penetration (0.97 vs. 0.83; P = .0002), and laryngopharyngeal residues (0.97 vs. 0.80; P < .0001). Sensitivity to detect pharyngeal premature spillage was similar for both tests (VFSS: 0.80; FEES: 0.69; P = .28). The specificities of both tests were similar (range, 0.93–0.98). In the sensitivity analysis there were statistically significant differences between the tests regarding residues but only marginally significant differences regarding aspiration and penetration. Conclusions: FEES had a slight advantage over VFSS to detect aspiration, penetration, and residues. Prospective studies comparing both tests against an appropriate reference standard are needed to define which test has greater accuracy. Level of Evidence: 2a Laryngoscope, 127:2002–2010, 2017

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.26419

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 212

Metadata

Authors
Giraldo‐Cadavid, L. F., Leal‐Leaño, L. R., Leon‐Basantes, G. A., Bastidas, A. R., Garcia, R., Ovalle, S., & Abondano‐Garavito, J. E.
Venue
The Laryngoscope
Publisher
Wiley
Published
2016-11-15
Volume
127
Issue
9
Pages
2002-2010
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2557145896
Cited by
212
References
3
FWCI
16.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia. https://app.cochat.ai/papers/10.1002/lary.26419
The paper
Giraldo‐Cadavid, L. F., Leal‐Leaño, L. R., Leon‐Basantes, G. A., Bastidas, A. R., Garcia, R., Ovalle, S., & Abondano‐Garavito, J. E. (2017). Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia. The Laryngoscope. https://doi.org/10.1002/lary.26419

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.