Sensitivity‐enhancement methods for surface plasmon sensors
The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
Surface plasmon resonance (SPR) sensors have been a mature technology for more than two decades now, however, recent investigations show continuous enhancement of their sensitivity and their lower detection limit. Together with the recent investigations in localized SPR phenomena, extraordinary optical transmission through nanoapertures in metals, and surface‐enhanced spectroscopies, drastic developments are expected to revolutionize the field of optical biosensing. Sensitivity‐enhancement (SE) techniques are reviewed focusing both on the physical transduction mechanisms and the system performance. In the majority of cases the SE is associated with the enhancement of the electromagnetic field overlap integral describing the interaction energy within the analyte. Other important mechanisms are the interaction between plasmons and excitons and between the analyte molecules and the metal surface. The lower detection limit can be reduced significantly if systems with high signal‐to‐noise ratio are used such as common‐path interferometry, ellipsometry or polarimetry systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasmonics: Fundamentals and Applications
Maier, S. A. (2007) · Springer eBooks · doi:10.1007/0-387-37825-1 · Cited by 9,728
Optical Properties of Metal Clusters
Kreibig, U., & Vollmer, M. (1995) · Springer Series in Materials Science · doi:10.1007/978-3-662-09109-8 · Cited by 7,896
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Surface Plasmons on Smooth and Rough Surfaces and on Gratings
Raether, H. (1988) · Springer Tracts in Modern Physics · doi:10.1007/bfb0048317 · Cited by 5,538
Moskovits, M. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.783 · Cited by 5,466
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
Size and Temperature Dependence of the Plasmon Absorption of Colloidal Gold Nanoparticles
Link, S., & El-Sayed, M. A. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp984796o · Cited by 2,787
Theory of Diffraction by Small Holes
Bethe, H. A. (1944) · Physical Review · doi:10.1103/physrev.66.163 · Cited by 2,607
Cited by
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Damborský, P., Švitel, J., & Katrlík, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150010 · Cited by 907
Perspectives on oblique angle deposition of thin films: From fundamentals to devices
Barranco, A., Borras, A., Gonzalez-Elipe, A. R., & Palmero, A. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2015.06.003 · Cited by 739
Review of plasmonic fiber optic biochemical sensors: improving the limit of detection
Caucheteur, C., Guo, T., & Albert, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8411-6 · Cited by 729
Xu, Y., Bai, P., Zhou, X., Akimov, Y., Png, C. E., Ang, L., Knoll, W., & Wu, L. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801433 · Cited by 519
Ouyang, Q., Zeng, S., Jiang, L., Hong, L., Xu, G., Dinh, X.-Q., Qian, J., He, S., Qu, J., Coquet, P., et al. (2016) · Scientific Reports · doi:10.1038/srep28190 · Cited by 420
A PRIMER ON SURFACE PLASMON-POLARITONS IN GRAPHENE
BLUDOV, Y. V., FERREIRA, A., PERES, N. M. R., & VASILEVSKIY, M. I. (2013) · International Journal of Modern Physics B · doi:10.1142/s0217979213410014 · Cited by 382
Xu, Y., Ang, Y. S., Wu, L., & Ang, L. K. (2019) · Nanomaterials · doi:10.3390/nano9020165 · Cited by 207
“To obtain a highly sensitive SPR sensor, various techniques have been proposed and demonstrated [7], such as coating a dielectric material on the metal film [8].”
MethodPortable and field-deployed surface plasmon resonance and plasmonic sensors
Masson, J.-F. (2020) · The Analyst · doi:10.1039/d0an00316f · Cited by 195
Guo, T., Liu, F., Liang, X., Qiu, X., Huang, Y., Xie, C., Xu, P., Mao, W., Guan, B.-O., & Albert, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.047 · Cited by 182
Metallic Plasmonic Array Structures: Principles, Fabrications, Properties, and Applications
Yang, K., Yao, X., Liu, B., & Ren, B. (2021) · Advanced Materials · doi:10.1002/adma.202007988 · Cited by 178
Spectroscopy and Biosensing with Optically Resonant Dielectric Nanostructures
Krasnok, A., Caldarola, M., Bonod, N., & Alú, A. (2018) · Advanced Optical Materials · doi:10.1002/adom.201701094 · Cited by 173
Determining the Interfacial Refractive Index via Ultrasensitive Plasmonic Sensors
Zhan, C., Liu, B.-W., Tian, Z.-Q., & Ren, B. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c01907 · Cited by 56
Metadata
- Authors
- Shalabney, A., & Abdulhalim, I.
- Venue
- Laser & Photonics Reviews
- Publisher
- Wiley
- Published
- 2011-03-29
- Volume
- 5
- Issue
- 4
- Pages
- 571-606
- ISSN
- 1863-8880 (ISSN-L)
- 1863-8899
- OpenAlex
- W2066029042
- Cited by
- 551
- References
- 83
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.