Centering balloon to improve esophageal photodynamic therapy

Panjehpour, Masoud, Overholt, Bergein F., Denovo, Robert C., Sneed, Rick E., Petersen, Mark G. · 1992 · Lasers in Surgery and Medicine
Cited by 44

The DOI matches its Crossref record.

Abstract

A cylindrical balloon was developed to improve delivery of circumferential light for photodynamic therapy (PDT) of esophageal carcinoma. The balloon consisted of a 36‐mm‐long clear cylindrical membrane and a central tube to hold a cylindrical diffuser in the center of the lumen. Three isotropic probes were placed on the outside of the balloon to allow measurement of delivered light dose to the esophageal mucosa. The balloon was tested in the normal esophagus of 8 dogs that were injected with 4.0 mg/kg of PHOTOFRIN R. Endoscopy was performed 48 hours following the injection, and under endoscopic observation the balloon assembly was passed, fixed in place, and inflated. A 1‐cm cylindrical diffuser was passed into the central tube and 150,300, and 600 Joules/cm of 630 nm laser light was delivered at 25 cm, 15 cm, and 5 cm proximal to the gastroesophageal junction. One control dog was illuminated using the cylindrical diffuser alone at doses of 300 and 600 Joules/cm of diffuser. Complete circumferential tissue response was obtained when the balloon was used. Relatively uniform light intensities were measured around the lumen. In contrast, noncircumferential and unpredictable PDT responses were generated when the cylindrical diffuser was used without the balloon. © 1992 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lsm.1900120611

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Panjehpour, M., Overholt, B. F., Denovo, R. C., Sneed, R. E., & Petersen, M. G.
Venue
Lasers in Surgery and Medicine
Publisher
Wiley
Published
1992-01
Volume
12
Issue
6
Pages
631-638
ISSN
  • 0196-8092 (ISSN-L)
  • 1096-9101
OpenAlex
W1992353276
Cited by
44
References
0
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).