Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Interstitial photodynamic therapy of nonresectable malignant glioma recurrences using 5‐aminolevulinic acid induced protoporphyrin IX

Beck, Tobias J., Kreth, Friedrich W., Beyer, Wolfgang, Mehrkens, Jan H., Obermeier, Andreas, Stepp, Herbert, Stummer, Walter, Baumgartner, Reinhold · 2007 · Lasers in Surgery and Medicine

Abstract

Background and Objective: Limited knowledge of the light and temperature distribution within the target volume in combination with non‐selective accumulation of the applied photosensitizers (PS) has hampered the clinical relevance of interstitial photodynamic therapy (iPDT) for treatment of malignant glioma patients. The current pilot study focused on the development and the clinical implementation of an accurate and reproducible irradiation scheme for iPDT using 5‐aminolevulinic acid (5‐ALA) induced protoporphyrin IX (PPIX) as a selectively working PS. Study Design/Materials and Methods: Monte Carlo simulations of fluence rate and heat transport simulations were performed using the optical properties of normal brain tissue infiltrated by tumor cells (absorption coefficient µa = 0.2 cm−1, reduced scattering coefficient: µ′s = 20 cm−1). A modified 3‐D treatment‐planning software was used to calculate both, the treatment‐volume and the exact position of the light diffusers within the lesion. The feasibility and the risk of iPDT were tested in 10 patients with small and circumscribed recurrent malignant gliomas. Results: The optimum distance between the implanted light diffusers was determined to be 9 mm with regard to both fluence rate and temperature distribution. For this distance a temperature increase above 42°C was not expected to occur. Up to six cylindrical light diffusers were stereotactically implanted to achieve a complete irradiation of the tumor volume, which was possible in every single patient (mean tumor volume: 5.9 cm 3). The total applied light fluence was between 4,320 J and 11,520 J. Side effects of iPDT were not observed. Median survival was 15 months. Conclusion: 5‐ALA iPDT in combination with a 3‐D treatment‐planning (which was based on optical and thermal simulations) is a safe and feasible treatment modality. The clinical impact of these findings deserves further prospective evaluation. Lasers Surg. Med. 39:386–393, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lsm.20507

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Beck, T. J., Kreth, F. W., Beyer, W., Mehrkens, J. H., Obermeier, A., Stepp, H., Stummer, W., & Baumgartner, R.
Venue
Lasers in Surgery and Medicine
Publisher
Wiley
Published
2007-06
Volume
39
Issue
5
Pages
386-393
ISSN
  • 0196-8092 (ISSN-L)
  • 1096-9101
OpenAlex
W2153159003
Cited by
203
References
2
FWCI
4.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.