The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Micromechanical Testing of Individual Collagen Fibrils
Abstract
Summary: A novel method based on AFM was used to attach individual collagen fibrils between a glass surface and the AFM tip, to allow force spectroscopy studies of these. The fibrils were deposited on glass substrates that are partly coated with Teflon AF®. A modified AFM tip was used to accurately deposit epoxy glue droplets on either end of the collagen fibril that cross the glass‐Teflon AF® interface, as to such attach it with one end to the glass and the other end to the AFM tip. Single collagen fibrils have been mechanically tested in ambient conditions and were found to behave reversibly up to stresses of 90 MPa. Within this regime a Young's modulus of 2–7 GPa was obtained. In aqueous media, the collagen fibrils could be tested reversibly up to about 15 MPa, revealing Young's moduli ranging from 0.2 to at most 0.8 GPa. magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viscoelastic properties of collagen: synchrotron radiation investigations and structural model
Puxkandl, R., Zizak, I., Paris, O., Keckes, J., Tesch, W., Bernstorff, S., Purslow, P., & Fratzl, P. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2001.1033 · Cited by 525
Bone indentation recovery time correlates with bond reforming time
Thompson, J. B., Kindt, J. H., Drake, B., Hansma, H. G., Morse, D. E., & Hansma, P. K. (2001) · Nature · doi:10.1038/414773a · Cited by 468
Direct quantification of the flexibility of type I collagen monomer
Sun, Y.-L., Luo, Z.-P., Fertala, A., & An, K.-N. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00685-x · Cited by 229
Structural changes in human type I collagen fibrils investigated by force spectroscopy
Graham, J. S., Vomund, A. N., Phillips, C. L., & Grandbois, M. (2004) · Experimental Cell Research · doi:10.1016/j.yexcr.2004.05.022 · Cited by 159
Gutsmann, T., Fantner, G. E., Kindt, J. H., Venturoni, M., Danielsen, S., & Hansma, P. K. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74366-0 · Cited by 130
Time-resolved X-ray diffraction from tendon collagen during creep using synchrotron radiation
Sasaki, N., Shukunami, N., Matsushima, N., & Izumi, Y. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00174-2 · Cited by 121
Structure and mechanical properties of rat tail tendon1
Betsch, D. F., & Baer, E. (1980) · Biorheology · doi:10.3233/bir-1980-171-211 · Cited by 78
Cited by
Collagen Structure and Stability
Shoulders, M. D., & Raines, R. T. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.032207.120833 · Cited by 3,923
Gower, L. B. (2008) · Chemical Reviews · doi:10.1021/cr800443h · Cited by 1,086
Hierarchical Structure and Nanomechanics of Collagen Microfibrils from the Atomistic Scale Up
Gautieri, A., Vesentini, S., Redaelli, A., & Buehler, M. J. (2011) · Nano Letters · doi:10.1021/nl103943u · Cited by 690
Mechanical Properties of Collagen Fibrils
Wenger, M. P. E., Bozec, L., Horton, M. A., & Mesquida, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.103192 · Cited by 566
Molecular mechanics of mineralized collagen fibrils in bone
Nair, A. K., Gautieri, A., Chang, S.-W., & Buehler, M. J. (2013) · Nature Communications · doi:10.1038/ncomms2720 · Cited by 538
Buehler, M. J. (2008) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2007.04.001 · Cited by 356
The materials science of collagen
Sherman, V. R., Yang, W., & Meyers, M. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.05.023 · Cited by 324
Stress-Strain Experiments on Individual Collagen Fibrils
Shen, Z. L., Dodge, M. R., Kahn, H., Ballarini, R., & Eppell, S. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.124602 · Cited by 310
Mechanical testing of electrospun PCL fibers
Croisier, F., Duwez, A.-S., Jérôme, C., Léonard, A. F., van der Werf, K. O., Dijkstra, P. J., & Bennink, M. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.08.015 · Cited by 305
Self-citationNano-mechanical properties of individual mineralized collagen fibrils from bone tissue
Hang, F., & Barber, A. H. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0413 · Cited by 127
Caenorhabditis elegans Body Mechanics Are Regulated by Body Wall Muscle Tone
Petzold, B. C., Park, S.-J., Ponce, P., Roozeboom, C., Powell, C., Goodman, M. B., & Pruitt, B. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.02.035 · Cited by 64
Metadata
- Authors
- van der Rijt, J. A. J., van der Werf, K. O., Bennink, M. L., Dijkstra, P. J., & Feijen, J.
- Venue
- Macromolecular Bioscience
- Publisher
- Wiley
- Published
- 2006-09-15
- Volume
- 6
- Issue
- 9
- Pages
- 697-702
- ISSN
- 1616-5187 (ISSN-L)
- 1616-5195
- OpenAlex
- W2143659399
- Cited by
- 361
- References
- 7
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.