Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins

Beck, Jennifer L., Colgrave, Michelle L., Ralph, Stephen F., Sheil, Margaret M.·2001·Mass Spectrometry Reviews

Abstract

I. Introduction 61 II. Binding of Small Molecules to DNA 62 A. Covalent Binding 62 B. Reversible (Noncovalent) DNA‐Binding Agents 65 III. DNA–Metal Ion Complexes 67 A. Platinum Complexes 70 B. Other Metal Ions 73 IV. DNA–Protein Complexes 74 A. Introduction 74 B. ESI‐MS of DNA–Protein Complexes 76 C. ESI‐MS Analysis of Proteolytic Products of DNA–Protein Complexes 79 D. ESI‐MS of Ternary DNA–Protein–Ligand Complexes 80 V. Conclusions 80 Abbreviations 81 References 81 Interactions of DNA with drugs, metal ions, and proteins are important in a wide variety of biological processes. With the advent of electrospray ionization (ESI) and matrix‐assisted laser desorption ionization (MALDI), mass spectrometry (MS) is now a well‐established tool for the characterization of the primary structures of biopolymers. The gentle nature of the ESI process, however, means that ESI‐MS is also finding application for the study of noncovalent and other fragile biomolecular complexes. We outline here the progress, to date, in the use of ESI‐MS for the study of noncovalent drug—DNA and protein—DNA complexes together with strategies that can be employed to examine the binding of small molecules and metal complexes to DNA. In the case of covalent complexes with DNA, sequence information can be derived from ESI‐MS used in conjunction with tandem mass spectrometry (MS/MS) and/or enzymatic digestion. MS/MS can also be used to probe the relative binding affinities of drugs that bind to DNA via noncovalent interactions. Overall, the work in this area, to date has demonstrated that ESI‐MS and MS/MS will prove to be valuable complements to other structural methods, offering advantages in terms of speed, specificity, and sensitivity. © 2001 John Wiley & Sons, Inc., Mass Spec Rev 20: 61–87, 2001

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mas.1003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
Beck, J. L., Colgrave, M. L., Ralph, S. F., & Sheil, M. M.
Venue
Mass Spectrometry Reviews
Publisher
Wiley
Published
2001-01
Volume
20
Issue
2
Pages
61-87
ISSN
  • 0277-7037 (ISSN-L)
  • 1098-2787
OpenAlex
W2092145209
Cited by
227
References
1
FWCI
9.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins. https://app.cochat.ai/papers/10.1002/mas.1003
The paper
Beck, J. L., Colgrave, M. L., Ralph, S. F., & Sheil, M. M. (2001). Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.1003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.