The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Collisional activation of peptide ions in FT‐ICR mass spectrometry
Abstract
I. Introduction 159 II. Experimental Techniques 160 A. Gas‐Phase Multiple‐Collision Activation (MCA‐CID) 160 1. On‐Resonance Excitation 160 2. Off‐Resonance Excitation 161 3. Distribution of the Number of Collisions 161 4. Pressure Profile 162 B. Surface‐Induced Dissociation (SID) 162 III. Collisional Energy Deposition Function (CEDF) 163 A. Direct Measurement of the CEDF 163 B. Thermometer Ion Method 164 C. Recursive Internal Energy Distribution Search Method (RIEDS) 164 D. RRKM Modeling of Fragmentation Efficiency Curves 164 IV. Factors That Affect the CEDF and the Efficiency of Energy Transfer 165 A. Collision Energy and the Pressure of the Collision Gas 165 B. Method of Collisional Activation (MCA‐CID or SID) 166 C. Properties of the Ion 167 1. MCA‐CID 167 2. SID 168 V. Master Equation Modeling 169 VI. Fragmentation Efficiency Curves (FECs) 170 A. Experimental Parameters 171 B. Properties of the Precursor Ion 172 C. Slow vs. Fast Ion Activation 174 VII. Shattering of Peptide Ions on Surfaces 175 A. FT‐ICR SID Experiments 175 B. Theoretical Description of Shattering 176 VIII. Concluding Remarks 178 Acknowledgments 178 References 178 In the last decade, the characterization of complex molecules, particularly biomolecules, became a focus of fundamental and applied research in mass spectrometry. Most of these studies utilize tandem mass spectrometry (MS/MS) to obtain structural information for complex molecules. Tandem mass spectrometry (MS/MS) typically involves the mass selection of a primary ion, its activation by collision or photon excitation, unimolecular decay into fragment ions characteristic of the ion structure and its internal excitation, and mass analysis of the fragment ions. Although the fundamental principles of tandem mass spectrometry of relatively small molecules are fairly well‐understood, our understanding of the activation and fragmentation of large molecules is much more primitive. For small ions, a single energetic collision is sufficient to dissociate the ion; however, this is not the case for complex molecules. For large ions, two fundamental limits severely constrain fragmentation in tandem mass spectrometry. First, the center‐of‐mass collision energy—the absolute upper limit of energy transfer in a collision process—decreases with increasing mass of the projectile ion for fixed ion kinetic energy and neutral mass. Secondly, the dramatic increase in density of states with increasing internal degrees of freedom of the ion decreases the rate of dissociation by many orders of magnitude at a given internal energy. Consequently, most practical MS/MS experiments with complex ions involve multiple‐collision activation (MCA‐CID), multi‐photon activation, or surface‐induced dissociation (SID). This review is focused on what has been learned in recent research studies concerned with fundamental aspects of MCA‐CID and SID of model peptides, with an emphasis on experiments carried out with Fourier transform ion cyclotron resonance mass spectrometers (FT‐ICR MS). These studies provide the first quantitative comparison of gas‐phase multiple‐collision activation and SID of peptide ions. Combining collisional energy‐resolved data with RRKM‐based modeling revealed the effect of peptide size and identity on energy transfer in collisions—very important characteristics of ion activation from fundamental and the analytical perspectives. Finally, the combination of FT‐ICR with SID was utilized to carry out the first time‐resolved experiments that examine the kinetics of peptide fragmentation. This has lead to the discovery that the time‐dependence of ion dissociation varies smoothly up to a certain collision energy, and then shifts dramatically to a time‐independent, extensive dissociation. This near‐instantaneous “shattering” of the ion generates a large number of relatively small fragment ions. Shattering of ions on surfaces opens up a variety of dissociation pathways that are not accessible with multiple‐collision and multiphoton excitation. © 2003 Wiley Periodicals, Inc., Mass Spec Rev 22:158–181, 2003; Published online in Wiley Interscience (www.interscience.wiley.com). DOI 10.1002/mas.10041
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Ion activation methods for tandem mass spectrometry
Sleno, L., & Volmer, D. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.703 · Cited by 529
Metadata
- Authors
- Laskin, J., & Futrell, J. H.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 22
- Issue
- 3
- Pages
- 158-181
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2170483189
- Cited by
- 186
- References
- 2
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.