The DOI matches its Crossref record.
Linear ion traps in mass spectrometry
Abstract
I. Introduction 000 II. Linear Multipoles 000 A. Multipole Fields 000 1. Multipole Potentials 000 2. Ion Motion in 2D Multipole Fields 000 3. Ion Motion in Quadrupole Fields 000 4. Ion Motion in Higher Multipole Fields 000 5. Linear Ion Guides, Collision Cells, and Traps 000 6. Collisional Cooling 000 7. Ion Excitation in the Presence of a Collision Gas 000 8. Ion Isolation 000 9. Trap Capacity 000 A. Mass Discrimination Effects 000 III. Linear Traps Combined with Other Mass Analyzers 000 A. Linear Traps Combined with 3D Paul Traps 000 B. Linear Ion Traps Combined with TOF Mass Analyzers 000 C. Linear Traps Combined with FTICR 000 IV. Linear Traps as Mass Spectrometers 000 A. Fourier Transform Mass Spectrometry in a Linear Quadrupole Ion Trap 000 B. Linear Quadrupole Ion Trap Mass Spectrometer with Radial Ion Ejection 000 C. Linear Quadrupole Ion Trap Mass Spectrometer with Axial Ejection 000 V. Summary and Outlook 000 Acknowledgments 000 List of Symbols 000 References 000 Linear ion traps are finding new applications in many areas of mass spectrometry. In a linear ion trap, ions are confined radially by a two‐dimensional (2D) radio frequency (RF) field, and axially by stopping potentials applied to end electrodes. This review focuses on linear ion trap instrumentation. Potentials and ion motion in linear multipole fields and methods of ion trapping, cooling, excitation, and isolation are described. This is followed by a description of various mass discrimination effects that have been reported with linear ion traps. Linear ion traps combined in various ways with three‐dimensional (3D) traps, time‐of‐flight (TOF) mass analyzers, and Fourier transform ion cyclotron resonance mass spectrometers are then given. Linear ion traps can be used as stand alone mass analyzers, and their use for mass analysis by Fourier transforming image currents, by mass selective radial ejection, and by mass selective axial ejection are reviewed. © 2004 Wiley Periodicals, Inc., Mass Spec Rev
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Release of the cell envelope protease PrtS in the growth medium of Streptococcus thermophilus 4F44
Chang, O. K., Perrin, C., Galia, W., Saulnier, F., Miclo, L., Roux, E., Driou, A., Humbert, G., & Dary, A. (2012) · International Dairy Journal · doi:10.1016/j.idairyj.2011.10.014 · Cited by 31
Metadata
- Authors
- Douglas, D. J., Frank, A. J., & Mao, D.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2004-04-06
- Volume
- 24
- Issue
- 1
- Pages
- 1-29
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2082656241
- Cited by
- 459
- References
- 0
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.