The DOI matches its Crossref record; 227 of the 227 references it cites were found in a registry or an index.
The use of mass spectrometry to analyze dried blood spots
Abstract
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large‐scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off‐line and on‐line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD‐APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided. © 2014 Wiley Periodicals, Inc. Mass Spec Rev 35:361–438, 2016.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
A SIMPLE PHENYLALANINE METHOD FOR DETECTING PHENYLKETONURIA IN LARGE POPULATIONS OF NEWBORN INFANTS
Guthrie, R., & Susi, A. (1963) · Pediatrics · doi:10.1542/peds.32.3.338 · Cited by 2,219
Bioanalytical Method Validation—A Revisit with a Decade of Progress
Shah, V. P., Midha, K. K., Findlay, J. W. A., Hill, H. M., Hulse, J. D., McGilveray, I. J., McKay, G., Miller, K. J., Patnaik, R. N., Powell, M. L., et al. (2000) · Pharmaceutical Research · doi:10.1023/a:1007669411738 · Cited by 1,572
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Analytical Methods Validation: Bioavailability, Bioequivalence, and Pharmacokinetic Studies
Shah, V. P., Midha, K. K., Dighe, S., McGilveray, I. J., Skelly, J. P., Yacobi, A., Layloff, T., Viswanathan, C. T., Edgar Cook, C., Mcdowall, R. D., et al. (1992) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600810324 · Cited by 1,121
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Cited by
van den Broek, I., Fu, Q., Kushon, S., Kowalski, M. P., Millis, K., Percy, A., Holewinski, R. J., Venkatraman, V., & Van Eyk, J. E. (2017) · Clinical Mass Spectrometry · doi:10.1016/j.clinms.2017.08.004 · Cited by 62
Eshghi, A., Pistawka, A. J., Liu, J., Chen, M., Sinclair, N. J. T., Hardie, D. B., Elliott, M., Chen, L., Newman, R., Mohammed, Y., et al. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001820 · Cited by 51
Grecsó, N., Zádori, A., Szécsi, I., Baráth, Á., Galla, Z., Bereczki, C., & Monostori, P. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233724 · Cited by 26
Metadata
- Authors
- Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2014-09-22
- Volume
- 35
- Issue
- 3
- Pages
- 361-438
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1926657495
- Cited by
- 262
- References
- 227
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of mass spectrometry to analyze dried blood spots. https://app.cochat.ai/papers/10.1002/mas.21441
- The paper
- Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016). The use of mass spectrometry to analyze dried blood spots. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.21441
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.