Validation of digital spiral analysis as outcome parameter for clinical trials in essential tremor
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Essential tremor, one of the most prevalent movement disorders, is characterized by kinetic and postural tremor affecting activities of daily living. Spiral drawing is commonly used to visually rate tremor intensity, as part of the routine clinical assessment of tremor and as a tool in clinical trials. We present a strategy to quantify tremor severity from spirals drawn on a digitizing tablet. We validate our method against a well‐established visual spiral rating method and compare both methods on their capacity to capture a therapeutic effect, as defined by the change in clinical essential tremor rating scale after an ethanol challenge. Fifty‐four Archimedes spirals were drawn using a digitizing tablet by nine ethanol‐responsive patients with essential tremor before and at five consecutive time points after the administration of ethanol in a standardized treatment intervention. Quantitative spiral tremor severity was estimated from the velocity tremor peak amplitude after numerical derivation and Fourier transformation of pen‐tip positions. In randomly ordered sets, spirals were scored by seven trained raters, using Bain and Findley's 0 to 10 rating scale. Computerized scores correlated with visual ratings (P < 0.0001). The correlation was significant at each time point before and after ethanol (P < 0.005). Quantitative ratings provided better sensitivity than visual rating to capture the effects of an ethanol challenge (P < 0.05). Using a standardized treatment approach, we were able to demonstrate that spirography time‐series analysis is a valid, reliable method to document tremor intensity and a more sensitive measure for small effects than currently available visual spiral rating methods. © 2011 Movement Disorder Society
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Zesiewicz, T. A., Elble, R., Louis, E. D., Hauser, R. A., Sullivan, K. L., Dewey, R. B., Ondo, W. G., Gronseth, G. S., & Weiner, W. J. (2005) · Neurology · doi:10.1212/01.wnl.0000163769.28552.cd · Cited by 371
Wenning, G. K., Kiechl, S., Seppi, K., Müller, J., Högl, B., Saletu, M., Rungger, G., Gasperi, A., Willeit, J., & Poewe, W. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70226-x · Cited by 302
Research works printed but not linked: 19
- 10.1002/mds.10376 · DOI · Paper page
- 10.1212/01.WNL.0000099075.19951.8C · DOI · Paper page
- 10.1002/mds.1184 · DOI · Paper page
- Fahn S, 1988, Parkinson's Disease and Movement Disorders, 271
- 10.1136/jnnp.56.8.868 · DOI · Paper page
- 10.1212/01.wnl.0000218297.90054.28 · DOI
- 10.1002/mds.22010 · DOI
- 10.1002/1531-8257(200007)15:4<678::AID-MDS1012>3.0.CO;2-0 · DOI · Paper page
- 10.1212/WNL.62.12.2320 · DOI · Paper page
- 10.1016/0165-0270(90)90140-B · DOI
- Pullman SL, 1998, Spiral analysis: a new technique for measuring tremor with a digitizing tablet, Mov Disord, 13, 85
- 10.1002/mds.21874 · DOI
- 10.1097/WNF.0b013E31807A32C6 · DOI · Paper page
- 10.1002/mds.22744 · DOI
- 10.1002/mds.23193 · DOI
- 10.1002/mds.10553 · DOI
- 10.1212/01.WNL.0000101722.95137.19 · DOI · Paper page
- 10.1016/j.parkreldis.2004.07.005 · DOI
- 10.1093/brain/awl190 · DOI · Paper page
Cited by
Using Portable Transducers to Measure Tremor Severity
Elble, R. J., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.320 · Cited by 95
Transducer‐based evaluation of tremor
Haubenberger, D., Abbruzzese, G., Bain, P. G., Bajaj, N., Benito‐León, J., Bhatia, K. P., Deuschl, G., Forjaz, M. J., Hallett, M., Louis, E. D., et al. (2016) · Movement Disorders · doi:10.1002/mds.26671 · Cited by 87
Self-citationHow to use pen and paper tasks to aid tremor diagnosis in the clinic
Alty, J., Cosgrove, J., Thorpe, D., & Kempster, P. (2017) · Practical Neurology · doi:10.1136/practneurol-2017-001719 · Cited by 78
Using Portable Transducers to Measure Tremor Severity
Elble, R., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.7916/d8dr2vcc · Cited by 43
Wearable sensors during drawing tasks to measure the severity of essential tremor
Ali, S. M., Arjunan, S. P., Peters, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08922-6 · Cited by 35
Metadata
- Authors
- Haubenberger, D., Kalowitz, D., Nahab, F. B., Toro, C., Ippolito, D., Luckenbaugh, D. A., Wittevrongel, L., & Hallett, M.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2011-06-28
- Volume
- 26
- Issue
- 11
- Pages
- 2073-2080
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2107240438
- Cited by
- 120
- References
- 3
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.