The DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.
Free‐living monitoring of Parkinson's disease: Lessons from the field
Open accessAbstract
Wearable technology comprises miniaturized sensors (eg, accelerometers) worn on the body and/or paired with mobile devices (eg, smart phones) allowing continuous patient monitoring in unsupervised, habitual environments (termed free‐living). Wearable technologies are revolutionizing approaches to health care as a result of their utility, accessibility, and affordability. They are positioned to transform Parkinson's disease (PD) management through the provision of individualized, comprehensive, and representative data. This is particularly relevant in PD where symptoms are often triggered by task and free‐living environmental challenges that cannot be replicated with sufficient veracity elsewhere. This review concerns use of wearable technology in free‐living environments for people with PD. It outlines the potential advantages of wearable technologies and evidence for these to accurately detect and measure clinically relevant features including motor symptoms, falls risk, freezing of gait, gait, functional mobility, and physical activity. Technological limitations and challenges are highlighted, and advances concerning broader aspects are discussed. Recommendations to overcome key challenges are made. To date there is no fully validated system to monitor clinical features or activities in free‐living environments. Robust accuracy and validity metrics for some features have been reported, and wearable technology may be used in these cases with a degree of confidence. Utility and acceptability appears reasonable, although testing has largely been informal. Key recommendations include adopting a multidisciplinary approach for standardizing definitions, protocols, and outcomes. Robust validation of developed algorithms and sensor‐based metrics is required along with testing of utility. These advances are required before widespread clinical adoption of wearable technology can be realized. © 2016 International Parkinson and Movement Disorder Society
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly
Kangas, M., Korpelainen, R., Vikman, I., Nyberg, L., & Jämsä, T. (2015) · Gerontology · doi:10.1159/000362720 · Cited by 18,909
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Accurate telemonitoring of Parkinson’s disease progression by non-invasive speech tests
Tsanas, A., Little, M., McSharry, P., & Ramig, L. (2009) · Nature Precedings · doi:10.1038/npre.2009.3920.1 · Cited by 829
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Comparison of low-complexity fall detection algorithms for body attached accelerometers
Kangas, M., Konttila, A., Lindgren, P., Winblad, I., & Jämsä, T. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.003 · Cited by 493
Lord, S., Galna, B., Verghese, J., Coleman, S., Burn, D., & Rochester, L. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/gls255 · Cited by 412
Self-citationQuantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
Del Din, S., Godfrey, A., & Rochester, L. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2419317 · Cited by 363
Self-citationDel Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
Self-citation
Cited by
Um, T. T., Pfister, F. M. J., Pichler, D., Endo, S., Lang, M., Hirche, S., Fietzek, U., & Kulić, D. (2017) · Proceedings of the 19th ACM International Conference on Multimodal Interaction · doi:10.1145/3136755.3136817 · Cited by 729
Ma, K., Xiong, N., Shen, Y., Han, C., Liu, L., Zhang, G., Wang, L., Guo, S., Guo, X., Xia, Y., et al. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00001 · Cited by 379
Long-term unsupervised mobility assessment in movement disorders
Warmerdam, E., Hausdorff, J. M., Atrsaei, A., Zhou, Y., Mirelman, A., Aminian, K., Espay, A. J., Hansen, C., Evers, L. J. W., Keller, A., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30397-7 · Cited by 306
Self-citationCamps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez-López, C., Moreno Arostegui, J. M., Cabestany, J., Català, A., Alcaine, S., Mestre, B., et al. (2018) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.10.017 · Cited by 224
Lonini, L., Dai, A., Shawen, N., Simuni, T., Poon, C., Shimanovich, L., Daeschler, M., Ghaffari, R., Rogers, J. A., & Jayaraman, A. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0071-z · Cited by 209
Metadata
- Authors
- Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2016-07-25
- Volume
- 31
- Issue
- 9
- Pages
- 1293-1313
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2465612755
- Cited by
- 370
- References
- 98
- FWCI
- 23.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Free‐living monitoring of Parkinson's disease: Lessons from the field. https://app.cochat.ai/papers/10.1002/mds.26718
- The paper
- Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016). Free‐living monitoring of Parkinson's disease: Lessons from the field. Movement Disorders. https://doi.org/10.1002/mds.26718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.