Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Wearable sensors for Parkinson’s disease: which data are worth collecting for training symptom detection models

Open access

Abstract

Machine learning algorithms that use data streams captured from soft wearable sensors have the potential to automatically detect PD symptoms and inform clinicians about the progression of disease. However, these algorithms must be trained with annotated data from clinical experts who can recognize symptoms, and collecting such data are costly. Understanding how many sensors and how much labeled data are required is key to successfully deploying these models outside of the clinic. Here we recorded movement data using 6 flexible wearable sensors in 20 individuals with PD over the course of multiple clinical assessments conducted on 1 day and repeated 2 weeks later. Participants performed 13 common tasks, such as walking or typing, and a clinician rated the severity of symptoms (bradykinesia and tremor). We then trained convolutional neural networks and statistical ensembles to detect whether a segment of movement showed signs of bradykinesia or tremor based on data from tasks performed by other individuals. Our results show that a single wearable sensor on the back of the hand is sufficient for detecting bradykinesia and tremor in the upper extremities, whereas using sensors on both sides does not improve performance. Increasing the amount of training data by adding other individuals can lead to improved performance, but repeating assessments with the same individuals—even at different medication states—does not substantially improve detection across days. Our results suggest that PD symptoms can be detected during a variety of activities and are best modeled by a dataset incorporating many individuals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-018-0071-z

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Data collection and sensor setup. a Individuals with PD underwent multiple clinical assessments spaced by 30 min during a first visit (day 1); assessments were done before and after each participant took their PD medication. A single follow-up assessment was performed about 2 weeks later during a second visit (day 2). During each assessment, participants performed a series of daily activities and standardized clinical tasks. b Overview of the MC10 BioStampRC senor; c Position of sensors on the body and sensor modalities; sensors were placed on both sides, although only one side is shown for clarity. Data were recorded from the accelerometer (acc) and gyroscope (gyro) sensors, or from the accelerometer and electromyography (EMG) sensor. Data from the EMG sensor was not used in the current study
Fig. 1 Data collection and sensor setup. a Individuals with PD underwent multiple clinical assessments spaced by 30 min during a first visit (day 1); assessments were done before and after each participant took their PD medication. A single follow-up assessment was performed about 2 weeks later during a second visit (day 2). During each assessment, participants performed a series of daily activities and standardized clinical tasks. b Overview of the MC10 BioStampRC senor; c Position of sensors on the body and sensor modalities; sensors were placed on both sides, although only one side is shown for clarity. Data were recorded from the accelerometer (acc) and gyroscope (gyro) sensors, or from the accelerometer and electromyography (EMG) sensor. Data from the EMG sensor was not used in the current studyCC BY · PubMed Central
Fig. 2 The effect of sensor location and number of sensors on model performance. AUROC curves for detection of bradykinesia and tremor using random forest population models a when trained on data from either a single hand (with dominant symptoms), both hands (Hand_Bi), or a combination of hand, forearm and thigh sensors unilaterally (Combo). Corresponding AUROC curves from CNN population models b for detection of bradykinesia and tremor. Using a combination of sensors did not yield any advantage to only using hand sensors. Solid lines indicate mean AUROC and shaded areas represent 95% confidence intervals
Fig. 2 The effect of sensor location and number of sensors on model performance. AUROC curves for detection of bradykinesia and tremor using random forest population models a when trained on data from either a single hand (with dominant symptoms), both hands (Hand_Bi), or a combination of hand, forearm and thigh sensors unilaterally (Combo). Corresponding AUROC curves from CNN population models b for detection of bradykinesia and tremor. Using a combination of sensors did not yield any advantage to only using hand sensors. Solid lines indicate mean AUROC and shaded areas represent 95% confidence intervalsCC BY · PubMed Central
Fig. 3 Symptom detection across activities. AUROC curves for bradykinesia and tremor detection using population models (random forest), split by groups of activities. Symptoms were detected equally well during both clinical structured tasks (e.g. finger to nose movements) and most of daily functional activities (walking and fine motor tasks, e.g. typing on a keyboard). The lowest AUROC was during the execution of gross motor tasks
Fig. 3 Symptom detection across activities. AUROC curves for bradykinesia and tremor detection using population models (random forest), split by groups of activities. Symptoms were detected equally well during both clinical structured tasks (e.g. finger to nose movements) and most of daily functional activities (walking and fine motor tasks, e.g. typing on a keyboard). The lowest AUROC was during the execution of gross motor tasksCC BY · PubMed Central
Fig. 4 Comparing performance of population models with different number of individuals in the training pool. Plots showing the trend in expected AUROC for bradykinesia and tremor detection when testing on a new individual, when using population models with varying numbers of individuals in the training pool. Shaded areas mark 95% confidence interval on the mean
Fig. 4 Comparing performance of population models with different number of individuals in the training pool. Plots showing the trend in expected AUROC for bradykinesia and tremor detection when testing on a new individual, when using population models with varying numbers of individuals in the training pool. Shaded areas mark 95% confidence interval on the meanCC BY · PubMed Central
Fig. 5 The effect of using training data from multiple assessments (session) on model performance. Boxplots show the distribution of AUROC across participants for population models trained on data from day 1 and tested on either day 1 or day 2. Adding data from multiple sessions improves the AUROC for bradykinesia detection on day 1. However, no significant changes in AUROC occur when models are tested on data from a different day (day 2). A similar pattern is observed for detection of tremor, although a modest improvement was observed on day 2
Fig. 5 The effect of using training data from multiple assessments (session) on model performance. Boxplots show the distribution of AUROC across participants for population models trained on data from day 1 and tested on either day 1 or day 2. Adding data from multiple sessions improves the AUROC for bradykinesia detection on day 1. However, no significant changes in AUROC occur when models are tested on data from a different day (day 2). A similar pattern is observed for detection of tremor, although a modest improvement was observed on day 2CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 214

Metadata

Authors
Lonini, L., Dai, A., Shawen, N., Simuni, T., Poon, C., Shimanovich, L., Daeschler, M., Ghaffari, R., Rogers, J. A., & Jayaraman, A.
Affiliations
  • Northwestern University (US)
  • Michael J. Fox Foundation (US)
Corresponding author
Jayaraman, Arun
Venue
npj Digital Medicine
Published
2018-11-23
Volume
1
Issue
1
Pages
64-64
ISSN
2398-6352 (ISSN-L)
OpenAlex
W2900586747
Cited by
209
References
42
Citations by year
2026: 11 · 2025: 31 · 2024: 23 · 2023: 31 · 2022: 29 · 2021: 38 · 2020: 32 · 2019: 14
FWCI
10.50
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Michael J. Fox Foundation for Parkinson's Research (14702)
  • Northwestern University (T32GM008152)
  • National Institutes of Health
  • Feinberg School of Medicine
  • National Institute of General Medical Sciences (T32GM008152)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
Keywords
Parkinson's disease, wearable sensors, bradykinesia, tremor, symptom detection, convolutional neural networks, statistical ensembles, movement data, sensor placement, training data size, cross-subject transfer, medication state, upper limb

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable sensors for Parkinson’s disease: which data are worth collecting for training symptom detection models. https://app.cochat.ai/papers/10.1038/s41746-018-0071-z
The paper
Lonini, L., Dai, A., Shawen, N., Simuni, T., Poon, C., Shimanovich, L., Daeschler, M., Ghaffari, R., Rogers, J. A., & Jayaraman, A. (2018). Wearable sensors for Parkinson’s disease: which data are worth collecting for training symptom detection models. npj Digital Medicine. https://doi.org/10.1038/s41746-018-0071-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.