Home‐Based Monitoring of Falls Using Wearable Sensors in Parkinson's Disease
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Introduction: Falling is among the most serious clinical problems in Parkinson's disease (PD). We used body‐worn sensors (falls detector worn as a necklace) to quantify the hazard ratio of falls in PD patients in real life. Methods: We matched all 2063 elderly individuals with self‐reported PD to 2063 elderly individuals without PD based on age, gender, comorbidity, and living conditions. We analyzed fall events collected at home via a wearable sensor. Fall events were collected either automatically using the wearable falls detector or were registered by a button push on the same device. We extracted fall events from a 2.5‐year window, with an average follow‐up of 1.1 years. All falls included were confirmed immediately by a subsequent telephone call. The outcomes evaluated were (1) incidence rate of any fall, (2) incidence rate of a new fall after enrollment (ie, hazard ratio), and (3) 1‐year cumulative incidence of falling. Results: The incidence rate of any fall was higher among self‐reported PD patients than controls (2.1 vs. 0.7 falls/person, respectively; P < .0001). The incidence rate of a new fall after enrollment (ie, hazard ratio) was 1.8 times higher for self‐reported PD patients than controls (95% confidence interval, 1.6–2.0). Conclusion: Having PD nearly doubles the incidence of falling in real life. These findings highlight PD as a prime “falling disease.” The results also point to the feasibility of using body‐worn sensors to monitor falls in daily life. © 2019 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and Movement Disorder Society.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austin, P. C. (2011) · Multivariate Behavioral Research · doi:10.1080/00273171.2011.568786 · Cited by 12,242 · cited 1×
“For the matching procedure we used the propensity score matching technique, matching cases with a nearest-neighbor approach guided by logit scores.(21) The dataset used here is composed of a preexisting dataset of participants whose personal data have been pseudonymized.”
MethodTechnology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
Self-citationFall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215 · cited 1×
“In the past years, several initiatives applied wearable sensors for fall detection with good results.(29) More work is needed to validate accurate algorithms, especially in real life,(30,31) where reliable ground truth is challenging and achieving high accuracy is ambitious because of confounding daily living activiti…”
BackgroundFeasibility of large-scale deployment of multiple wearable sensors in Parkinson's disease
Silva de Lima, A. L., Hahn, T., Evers, L. J. W., de Vries, N. M., Cohen, E., Afek, M., Bataille, L., Daeschler, M., Claes, K., Boroojerdi, B., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0189161 · Cited by 162
Self-citationIluz, T., Gazit, E., Herman, T., Sprecher, E., Brozgol, M., Giladi, N., Mirelman, A., & Hausdorff, J. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-48 · Cited by 76 · cited 1×
“Moreover, wearable sensors have potential to identify patients with a high risk of falling.(33) Consequently, monitoring with sensors may increase timely referral to falls prevention programs, aiming to decrease the impact of falls on daily life and increase independence.”
Background
Cited by
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Bloem, B. R., Henderson, E. J., Dorsey, E. R., Okun, M. S., Okubadejo, N., Chan, P., Andrejack, J., Darweesh, S. K. L., & Munneke, M. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(20)30064-8 · Cited by 242
Self-citationThe Coronavirus Disease 2019 Crisis as Catalyst for Telemedicine for Chronic Neurological Disorders
Bloem, B. R., Dorsey, E. R., & Okun, M. S. (2020) · JAMA Neurology · doi:10.1001/jamaneurol.2020.1452 · Cited by 224
Self-citationAccelerating Parkinson’s Disease drug development with federated learning approaches
Khanna, A., Adams, J., Antoniades, C., Bloem, B. R., Carroll, C., Cedarbaum, J., Cosman, J., Dexter, D. T., Dockendorf, M. F., Edgerton, J., et al. (2024) · npj Parkinson's Disease · doi:10.1038/s41531-024-00837-5 · Cited by 21
“For example,measuressuchasbradykinesia 57 ,gait 58 ,tremor 59 ,falls 60 ,sleep 61 ,and speech pattern abberations 62 are all Concepts of Interest (COI ’ s) that might be considered depending on various Contexts of Use (CoU ’ s).”
Self-citation
Metadata
- Authors
- Silva de Lima, A. L., Smits, T., Darweesh, S. K. L., Valenti, G., Milosevic, M., Pijl, M., Baldus, H., de Vries, N. M., Meinders, M. J., & Bloem, B. R.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2019-08-26
- Volume
- 35
- Issue
- 1
- Pages
- 109-115
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2970424927
- Cited by
- 116
- References
- 5
- FWCI
- 28.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Home‐Based Monitoring of Falls Using Wearable Sensors in Parkinson's Disease. https://app.cochat.ai/papers/10.1002/mds.27830
- The paper
- Silva de Lima, A. L., Smits, T., Darweesh, S. K. L., Valenti, G., Milosevic, M., Pijl, M., Baldus, H., de Vries, N. M., Meinders, M. J., & Bloem, B. R. (2020). Home‐Based Monitoring of Falls Using Wearable Sensors in Parkinson's Disease. Movement Disorders. https://doi.org/10.1002/mds.27830
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.