Abstract

Wearable devices have found numerous applications in healthcare ranging from physiological diseases, such as cardiovascular diseases, hypertension and muscle disorders to neurocognitive disorders, such as Parkinson’s disease, Alzheimer’s disease and other psychological diseases. Different types of wearables are used for this purpose, for example, skin-based wearables including tattoo-based wearables, textile-based wearables, and biofluidic-based wearables. Recently, wearables have also shown encouraging improvements as a drug delivery system; therefore, enhancing its utility towards personalized healthcare. These wearables contain inherent challenges, which need to be addressed before their commercialization as a fully personalized healthcare system. This paper reviews different types of wearable devices currently being used in the healthcare field. It also highlights their efficacy in monitoring different diseases and applications of healthcare wearable devices (HWDs) for diagnostic and treatment purposes. Additionally, current challenges and limitations of these wearables in the field of healthcare along with their future perspectives are also reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41528-021-00107-x

Cites

122 of 122 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Classi fi cation of Healthcare Wearable Devices (HWDs). Organization of the paper showing the classi fi cation of HWDs including Skin based HWDs, Bio fl uidic based HWDs, and Wearable Drug Delivery Systems along with their sub-categories.
Fig. 1 Classi fi cation of Healthcare Wearable Devices (HWDs). Organization of the paper showing the classi fi cation of HWDs including Skin based HWDs, Bio fl uidic based HWDs, and Wearable Drug Delivery Systems along with their sub-categories.CC-BY · From the PDF
Fig. 2 Textile-based HWDs for measuring vital bio signals for example ECG, EEG, and EMG. a Comparison of ECG signals from Ag/AgCl electrodes and ECG HWD. Reproduced with permission from Yapici et al. 23 Copyright © Sensors, 2017. b Textile-based ECG electrode c , d ECG vs time graphs of the textile-based ECG electrode. Reproduced with permission from Arquilla et al. 25 Copyright © Sensors, 2020. e E-TeCS wearable with sensors on the shirt. Reproduced with permission from Wicaksono et al. 26 Copyright © npj Flexible Electronics, 2020. f Multisensor textile-based electrode for EEG and sweat rate measurement. g Comparison of textile-based electrode, as illustrated in f , with traditional EEG electrode for alpha rhythm detection during eyes closed. Reproduced with permission from Gao et al. 28 Copyright © IEEE Sensors Journal, 2020. h Wearable shirt for the monitoring of EMG. Reproduced with permission from Pino et al. 30 Copyright © IEEE Conference of the IEEE Engineering in Medicine and Biology Society, 2018.
Fig. 2 Textile-based HWDs for measuring vital bio signals for example ECG, EEG, and EMG. a Comparison of ECG signals from Ag/AgCl electrodes and ECG HWD. Reproduced with permission from Yapici et al. 23 Copyright © Sensors, 2017. b Textile-based ECG electrode c , d ECG vs time graphs of the textile-based ECG electrode. Reproduced with permission from Arquilla et al. 25 Copyright © Sensors, 2020. e E-TeCS wearable with sensors on the shirt. Reproduced with permission from Wicaksono et al. 26 Copyright © npj Flexible Electronics, 2020. f Multisensor textile-based electrode for EEG and sweat rate measurement. g Comparison of textile-based electrode, as illustrated in f , with traditional EEG electrode for alpha rhythm detection during eyes closed. Reproduced with permission from Gao et al. 28 Copyright © IEEE Sensors Journal, 2020. h Wearable shirt for the monitoring of EMG. Reproduced with permission from Pino et al. 30 Copyright © IEEE Conference of the IEEE Engineering in Medicine and Biology Society, 2018.CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Fig. 4 Other competitive skin-based HWDs. a Schematic of the Heart Failure Prediction System. Reproduced with permission from Ha fi d et al. 48 Copyright © IEEE Journal Of Biomedical and Health Informatics,2018. b Oura Ring with miniaturized sensors on it to diagnose different illnesses. Reproduced with permission 50 Copyright © Oura Ring, 2020. c Position of sensors for the detection of bradykinesia and tremor features of PD. Reproduced with permission from Lonini et al. 71 Copyright © npj Digital Medicine, 2018. d Earphones for the portable acquisition of EEG with reference and ground electrodes on left earphone and source electrode on right earphone. e Power Spectral Density (PSD) for the differentiation of the state of drowsiness and awake state using EEG from HWD as illustrated in d . Reproduced with permission from Lee et al. 78 Copyright © ACS Applied Materials and Interfaces, 2018.
Fig. 4 Other competitive skin-based HWDs. a Schematic of the Heart Failure Prediction System. Reproduced with permission from Ha fi d et al. 48 Copyright © IEEE Journal Of Biomedical and Health Informatics,2018. b Oura Ring with miniaturized sensors on it to diagnose different illnesses. Reproduced with permission 50 Copyright © Oura Ring, 2020. c Position of sensors for the detection of bradykinesia and tremor features of PD. Reproduced with permission from Lonini et al. 71 Copyright © npj Digital Medicine, 2018. d Earphones for the portable acquisition of EEG with reference and ground electrodes on left earphone and source electrode on right earphone. e Power Spectral Density (PSD) for the differentiation of the state of drowsiness and awake state using EEG from HWD as illustrated in d . Reproduced with permission from Lee et al. 78 Copyright © ACS Applied Materials and Interfaces, 2018.CC-BY · From the PDF
Fig. 5 Bio fl uidic-based HWDs. a Colorimetric analysis of sweat from the image captured using smartphone. b Quanti fi cation of the concentration of chloride, hydronium ions, and glucose and lactate levels using HWD as illustrated in a . Reproduced with permission from Koh et al. 83 Copyright © Science Translational Medicine, 2016. c A skin-like soft wearable micro fl uidic platform for the detection of different analytes from sweat. d Concentrations of sodium, potassium, and lactate at different body locations and at different chambers of the HWD illustrated in c . Reproduced with permission from Choi et al. 90 Copyright © Advanced Healthcare Materials, 2017. e Smart contact lens for the monitoring of diabetes using smartphone. Reproduced with permission from Lin et al. 98 Copyright © Sensors, 2018.
Fig. 5 Bio fl uidic-based HWDs. a Colorimetric analysis of sweat from the image captured using smartphone. b Quanti fi cation of the concentration of chloride, hydronium ions, and glucose and lactate levels using HWD as illustrated in a . Reproduced with permission from Koh et al. 83 Copyright © Science Translational Medicine, 2016. c A skin-like soft wearable micro fl uidic platform for the detection of different analytes from sweat. d Concentrations of sodium, potassium, and lactate at different body locations and at different chambers of the HWD illustrated in c . Reproduced with permission from Choi et al. 90 Copyright © Advanced Healthcare Materials, 2017. e Smart contact lens for the monitoring of diabetes using smartphone. Reproduced with permission from Lin et al. 98 Copyright © Sensors, 2018.CC-BY · From the PDF
Fig. 6 HWDs for drug delivery. a Ocular Ring for the treatment of glaucoma. Reproduced with permission from Brandt et al. 101 Copyright © American Academy of Ophthalmology, 2017. b Self-healable gum made from PATA biomaterial. c Gum, as illustrated in b , fi lled with a drug and treated in an oral cavity. Reproduced with permission from Al-Shahbazi et al. 104 Copyright © Journal of Materials Chemistry B, 2020. d Working principle of touch actuated transdermal drug delivery. Reproduced with permission from Kim et al. 105 Copyright © Sensors and Actuators, 2018. e Smart contact lens for diabetic retinopathy therapy by detecting glucose level. f comparison of glucose levels in blood and tear for normal and diabatic person. Reproduced with permission from Keum et al. 97 Copyright ©, Science Advances, 2020. g Working principle of wirelessly controlled smart bandage. Reproduced with permission from Derakhshandeh et al. 108 Copyright ©, Advanced Functional Materials, 2020.
Fig. 6 HWDs for drug delivery. a Ocular Ring for the treatment of glaucoma. Reproduced with permission from Brandt et al. 101 Copyright © American Academy of Ophthalmology, 2017. b Self-healable gum made from PATA biomaterial. c Gum, as illustrated in b , fi lled with a drug and treated in an oral cavity. Reproduced with permission from Al-Shahbazi et al. 104 Copyright © Journal of Materials Chemistry B, 2020. d Working principle of touch actuated transdermal drug delivery. Reproduced with permission from Kim et al. 105 Copyright © Sensors and Actuators, 2018. e Smart contact lens for diabetic retinopathy therapy by detecting glucose level. f comparison of glucose levels in blood and tear for normal and diabatic person. Reproduced with permission from Keum et al. 97 Copyright ©, Science Advances, 2020. g Working principle of wirelessly controlled smart bandage. Reproduced with permission from Derakhshandeh et al. 108 Copyright ©, Advanced Functional Materials, 2020.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 122 references

Research works printed but not linked: 3

  1. Min, W. & Jake, L. Wearable technology applications in healthcare: a literature review. Online J. Nurs. Informatics Contrib. https://www.himss.org/resources/wearable-technology-applications-healthcare-literature-review (2019).
  2. Savarese, G. & Lund, L. H. Pharmacological therapy nitrates as a treatment of acute heart failure pharmacological therapy. J. Hear. Team 3, 51–55 (2016).
  3. Bhagwat, R. R. & Vaidhya, I. S. Novel drug delivery systems: An Overview. Int. J. Pharm. Sci. Res. 4, 970–982 (2013).

Cited by

See all 777

Metadata

Authors
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W.
Affiliations
Florida Atlantic University (US)
Corresponding author
Asghar, Waseem
Venue
npj Flexible Electronics
Published
2021-04-12
Volume
5
Issue
1
ISSN
2397-4621 (ISSN-L)
OpenAlex
W3155494946
Cited by
714
References
122
Citations by year
2026: 122 · 2025: 188 · 2024: 172 · 2023: 130 · 2022: 86 · 2021: 15
FWCI
30.61
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Flexible Electronics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Science Foundation (1942487, CAREER)
  • Florida Atlantic University
  • Universidad del Atlántico
  • National Institutes of Health (1942487)
  • National Institute of Allergy and Infectious Diseases (R15AI127214)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
physiological monitoring, cardiovascular disease, hypertension, muscle disorders, neurocognitive disorders, Parkinson's disease, Alzheimer's disease, drug delivery systems, personalized healthcare

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advances in healthcare wearable devices. https://app.cochat.ai/papers/10.1038/s41528-021-00107-x
The paper
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021). Advances in healthcare wearable devices. npj Flexible Electronics. https://doi.org/10.1038/s41528-021-00107-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.