Magnetic resonance–guided focused ultrasound thalamotomy for treatment of essential tremor: A 2‐year outcome study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Magnetic resonance–guided focused ultrasound is an emerging, minimally invasive thermoablation technique for medically refractory essential tremor. Beyond the initial year, data regarding efficacy and potential predictors of efficacy are still preliminary. Objectives: The objective of this study was to assess the outcome at 2 years and the association between lesion volume and outcome 1 year after treatment. Methods: We reviewed data from 37 patients who underwent unilateral magnetic resonance–guided focused ultrasound thalamotomy, with primary outcome being dominant tremor subscore of the Clinical Rating Scale for Tremor. We used multivariable linear regression to model initial lesion volume with 1‐year outcome, adjusting for other clinically relevant variables. Results: Although we detected a trend in loss of clinical benefit within the first year, the dominant tremor score at 2 years continued to be significantly improved (43.4%, 95% confidence interval 27.8%‐59.0%) from baseline. Secondarily, initial lesion volume is significantly associated with 1‐year outcome. Conclusion: Our findings show that magnetic resonance–guided focused ultrasound thalamotomy results in sustained tremor reduction for medically refractory essential tremor even in the long term, and we highlight areas for improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Lipsman, N., Ondo, W. G., Ghanouni, P., Kim, Y. G., Lee, W., Schwartz, M., Hynynen, K., Lozano, A. M., Shah, B. B., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1600159 · Cited by 1,167
Self-citationChang, J. W., Park, C. K., Lipsman, N., Schwartz, M. L., Ghanouni, P., Henderson, J. M., Gwinn, R., Witt, J., Tierney, T. S., Cosgrove, G. R., et al. (2018) · Annals of Neurology · doi:10.1002/ana.25126 · Cited by 178 · cited 1×
“Second, a considerable portion of initial patients were not assessed at 2 years as result of loss to followup, which may contribute to the discrepancy with relatively more positive outcomes in the recent 2-year study.(6) The group lost to follow-up could also represent patients with worse outcomes.”
ResultSelf-citation
Cited by
Applications of focused ultrasound in the brain: from thermoablation to drug delivery
Meng, Y., Hynynen, K., & Lipsman, N. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00418-z · Cited by 505
Self-citationIzadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
“MRgFUS thalamotomy leads to sustained tremor reduction for medically refractory ET in the long term [117].”
BackgroundEssential tremor: diagnosis and management
Shanker, V. (2019) · BMJ · doi:10.1136/bmj.l4485 · Cited by 182
di Biase, L., Falato, E., & Di Lazzaro, V. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00549 · Cited by 166
Metadata
- Authors
- Meng, Y., Solomon, B., Boutet, A., Llinas, M., Scantlebury, N., Huang, Y., Hynynen, K., Hamani, C., Fasano, A., Lozano, A. M., Lipsman, N., & Schwartz, M. L.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2018-10
- Volume
- 33
- Issue
- 10
- Pages
- 1647-1650
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2895468999
- Cited by
- 68
- References
- 2
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.