Physiologic tremor and microsurgery
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Physiologic tremor hampers the ability of students to learn microsurgical technique. An understanding of normal tremor both as to origin and methods of control would be of help. Physiological tremor arises from both mechanical and neuromuscular sources and is made worse by a number of factors. The “size principle of motoneuron recruitment” is an important physiologic consideration, and the use of biofeedback techniques enables the student to confirm his understanding of the principle. Knowledge of the factors which aggravate physiological tremor allows the microsurgeon to control his own tremor both in the laboratory and in the operating room.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most familiar type of erroneous movement affecting micromanipulation is hand tremor [2].”
From Active tremor compensation in microsurgery (2005) · cites this paper as [2]
In the citing paper
“and average rms error reduction of 30% with respect to an offline estimate of the tremor-free component of motion.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“The WFLC is an adaptive algorithm that estimates tremor using a dynamic sinusoidal model, estimating its time-varying frequency, amplitude, and phase online.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“Active canceling of physiological tremor using this algorithm has been demonstrated using a 1-dof instrument prototype.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“In 25 tests on hand motion recorded from eye surgeons, this technique yielded average rms amplitude reduction of 69% in the 6-16 Hz band”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
Citations
Cites
The orderly recruitment of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010192 · Cited by 920
The relation between integrated action potentials in a human muscle and its isometric tension
Lippold, O. C. J. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004763 · Cited by 653
The contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476
Neurophysiological Basis of Normal and Abnormal Motor Activities.
(1968) · Archives of Neurology · doi:10.1001/archneur.1968.00480040114016 · Cited by 405
Fatigue of maintained voluntary muscle contraction in man
Stephens, J. A., & Taylor, A. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009691 · Cited by 320
Neuronal mechanisms underlying physiological tremor
Allum, J. H., Dietz, V., & Freund, H. J. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.3.557 · Cited by 309
Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor
Elble, R. J., & Randall, J. E. (1976) · Journal of Neurophysiology · doi:10.1152/jn.1976.39.2.370 · Cited by 300
Neurophysiology Studied in Man
GILMAN, S. (1973) · Neurology · doi:10.1212/wnl.23.10.1140 · Cited by 298
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
Research works printed but not linked: 6
- Marsden CD, 1978, The mechanisms of physiological tremor and their significance for pathological tremors, Prog Clin Neurophysio, 5, 1
- Marshall J, 1968, Tremor, Handbook Clin Neurol, 6, 809
- Rack PMH, 1978, Mechanical and reflex factors in human tremor, Prog Clin Neurophysio, 5, 17
- Dietrichson P, 1978, Quantitation of tremor in man, Prog Clin Neurophysio, 5, 90
- Henneman E, 1981, The size principle of motoneuron recruitment. Motor unit types, recruitment and plasticity in health and disease, Prog Clin Neurophysiol, 19, 26
- Stetson RH, 1935, The coordination of simple skilled movements, Arch Neerl Physio, 20, 177
Cited by
Items 101–134 of 134
Vision-Based Control of a Handheld Micromanipulator for Robot-Assisted Retinal Surgery
Becker, B. C. (2012) · KiltHub Repository · doi:10.1184/r1/6724241 · Cited by 3
Design and implementation of a two degree-of-freedom micromanipulation assessment system
Latt, W. T., Ananda, E. S., Ong, S. C. L., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650493 · Cited by 3
Jerk as a Method of Identifying Physical Fatigue and Skill Level in Construction Work
Zhang, L. (2019) · UWSpace (University of Waterloo) · Cited by 2
(2016) · ARC Journal of Dental Science · doi:10.20431/2456-0030.0104003 · Cited by 2
Comparison of training effect on tremor using 2 training modules
Payal, A. R., Kim, Y. J., González, L. A., & Daly, M. K. (2017) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2017.01.021 · Cited by 2
Design and Analysis of a Hand-Held Surgical Forceps with a Force-Holding Function
Bai, Y., Yu, Y., & Xu, Z. (2024) · Sensors · doi:10.3390/s24185895 · Cited by 1
Influence of pre-cooling garments on elite pistol shooting performance
Sanders, N. (2014) · RMIT Research Repository (RMIT University Library) · doi:10.25439/rmt.27339903 · Cited by 1
A system for evaluation of surgical hand tremor
Kulwicki, K. J., Harris, G. F., & Cooley, B. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.978963 · Cited by 1
Changes in tremor as a function of type of augmented visual information
Loncharich, M. F., & Newell, K. M. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2239-y · Cited by 1
Constraints on the Control of Physiological Tremor
Keogh, J. W. L. (2006) · Griffith Research Online · doi:10.25904/1912/350 · Cited by 1
Microsurgery in Guided Bone Regeneration
Llamosa-Cáñez, L. (2022) · Springer eBooks · doi:10.1007/978-3-030-96874-8_11 · Cited by 1
Haworth, J., Opfermann, J. D., Kam, M., Wang, Y., Yang, R. S., Kang, J. U., & Krieger, A. (2023) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48891.2023.10161296 · Cited by 1
A Digital Stereo Microscope Platform for Microsurgery Training
Rappel, J. K., Lahiri, A., & Teo, C. L. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-13987-6_28 · Cited by 1
MICROSURGERY IN PERIODONTOLOGY: A REVIEW
Lingala, S., Gattani, D. R., Gudadhe, B., & Sahai, R. R. (2017) · Canadian Journal of Applied Science and Technology - Canadian Journal of Applied Science and Technology · Cited by 1
Ferreira, M. A., Maia, M., Farah, M. E., & Ávila, M. P. D. (2026) · Springer eBooks · doi:10.1007/978-3-032-23052-2_59
Ferreira, M. A. [., Maia, M., Farah, M. E., & de Ávila, M. E. (2025) · Springer eBooks · doi:10.1007/978-3-031-29358-0_59-1
Sensing of physiological hand tremor for real-time compensation in micromanipulation
Latt, W. T. (2010) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/47169
Doğramacı, M., & STEEL, D. H. (2021) · Turkish Journal of Ophthalmology · doi:10.4274/tjo.galenos.2020.40035
Gallagher, A. G., & O’Sullivan, G. C. (2011) · Springer eBooks · doi:10.1007/978-0-85729-763-1_1
Evaluation of Smartphone as a Real-Time Tool for Hand Tremor Assessment
Natarajan, P., & Balasubramanian, V. (2021) · Design science and innovation · doi:10.1007/978-981-16-2229-8_24
ORGANISATION MULTI-SEGMENTAIRE DU TREMBLEMENT PHYSIOLOGIQUE DU MEMBRE SUPÉRIEUR
Carignan, B. (2010) · Archipel (Université du Québec à Montréal)
Novel Real-Time Tremor Transduction Technique for Microsurgery
Tomlin, D. H., Wallace, J. W., Etienne‐Cummings, R., & Thakor, N. V. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_45
Visual Information Influences Postural Tremor
Loncharich, M. F. (2011)
Logarithmic dimensionless jerk as a metric for movement smoothness in traditional archery
Ödek, U., & Ramis, Ç. (2025) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371251401034
A system for analysing surgical motion under a surgical visual aid
Rappel, J. K., Teo, C. L., & Lahiri, A. (2013) · International Conference on Information, Communications & Signal Processing (ICICS) · doi:10.1109/icics.2013.6782811
Carreira, L. M. A. (2014) · Repositório Comum (Repositório Científico de Acesso Aberto de Portugal)
Application of fingertip support technique in microsurgery
Csókay, G., Pataki, G., Óvári, A., Valálik, I., & Csókay, A. (2010) · Biomechanica Hungarica · doi:10.17489/biohun/2010/1/08
Bykanov, A., Pitskhelauri, D. I., Kirushin, M. A., Rastvorova, O., & Zagidullin, T. (2024) · Russian journal of neurosurgery · doi:10.17650/1683-3295-2024-26-1-76-82
Deficits in Surgical Technical Performance: Prolonged Effects of Alcohol—Reply
Gallagher, A. G. (2011) · Archives of Surgery · doi:10.1001/archsurg.2011.1028
Stancu, R.-F., Marques, M. J. M., Henry, R., Seneci, C., Sanderson, T., da Cruz, L., Bergeles, C., Hughes, M. R., & Podoleanu, A. G. (2023) · British and Irish Conference on Optics and Photonics (BICOP) · doi:10.1364/bicop.2023.ps.14
125 Micrometer Fiber Optic Sensors for Tissue Proximity Detection and B-Scan Acquisition
Stancu, R. F., Marques, M. J. M., Henry, R., Seneci, C., da Cruz, L., Bergeles, C., Hughes, M. R., & Podoleanu, A. G. (2024) · British and Irish Conference on Optics and Photonics (BICOP) · doi:10.1364/bicop.2024.th3b.1
Principles for successful outcomes in microsurgical guided bone regeneration
Llamosa-Cáñez, L. (2026) · Clinical Advances in Periodontics · doi:10.1002/cap.70061
Precision in action: Transitioning from novices to experts in microsurgery for practitioners
Sutthiboonyapan, P., & Sirinirund, B. (2026) · Clinical Advances in Periodontics · doi:10.1002/cap.70010
Metadata
- Authors
- Harwell, R. C., & Ferguson, R. L.
- Corresponding author
- Ferguson, R. Lawrence
- Venue
- Microsurgery
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 4
- Issue
- 3
- Pages
- 187-192
- ISSN
- 0738-1085 (ISSN-L)
- 1098-2752
- OpenAlex
- W1991955181
- Semantic Scholar
- 42605275e9aa5356befa74aa26a96aee6de6f623
- Cited by
- 131
- References
- 42
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 5 · 2021: 5 · 2020: 3 · 2019: 7 · 2018: 10 · 2017: 1 · 2016: 4 · 2015: 6 · 2014: 3 · 2013: 4 · 2012: 7
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Microsurgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Social Sciences › Education › Innovations in Medical Education
- Keywords
- physiological tremor, size principle, motoneuron recruitment, biofeedback, tremor control
- MeSH terms
- Biomechanical Phenomena, Electromyography, Fatigue, Hand, Humans, Microsurgery, Motor Neurons, Muscles, Stress, Psychological, Surgical Procedures, Operative, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.