Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor

Elble, R. J., Randall, J. E.·1976·Journal of Neurophysiology

Abstract

Tremor of the extended third digit and bipolar surface and needle electromyograms of the extensor digitorum were recorded from six healthy volunteers for the purpose of elucidating the motor-unit activity responsible for the 8- to 12-Hz component of physiological finger tremor. Tremor was measured with a force transducer during steady voluntary contractions of approximately 200-250 g. The surface EMGs were full-wave rectified and low-pass filtered (-3 dB at 21 Hz), producing the envelope of the surface EMG (the demodulated EMG). Spectral analyses of simultaneous tremor and demodulated EMG records were performed. In four of six subjects, a pronounced 8- to 12-Hz amplitude modulation in the surface EMG was present, and coherency analysis demonstrated that this modulation was strongly correlated with the well-known 8- to 12-Hz tremor. In two subjects this amplitude modulation and tremor were barely detectable, despite the sensitive recording and analysis techniques used in this study. Spectral analysis was performed on 43 motor-unit spike trains. Twenty-two spike trains, having mean firing frequencies in the range of 10-22 spikes/s, produced statistically significant spectral peaks at 8-12 Hz, in addition to the expected spectral peaks at the mean firing frequencies. Of the 22 8- to 12-Hz-producing motor units, 12 had mean firing frequencies in the range of 17-22 spikes/s and exhibited the greatest 8- to 12-Hz activities of all motor units recorded. These motor units displayed transient sequences of double discharges in which interspike intervals (ISIS) of approximately 8-30 ms alternated with ISIS of 60-90 ms, thus producing an 8- to 12-Hz spectral peak. Adjacent ISIS of these motor units were correlated in the range of -0.5 to -0.9. Coherency analyses demonstrated that the 8- to 12-Hz activities of these motor units were correlated with the 8- to 12-Hz finger tremor and surface EMG modulation. The remaining 10 8- to 12-Hz-producing motor units had mean firing frequencies in the range of 10-17 spike/s. Although these motor units did not display the intense double-discharge firing pattern of the more rapidly firing motor units, a tendency toward action potential grouping was present and resulted in 8- to 12-Hz spectral activities which were correlated with the tremor and surface EMG modulation. .. ..

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1976.39.2.370

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 300

Metadata

Authors
Elble, R. J., & Randall, J. E.
Venue
Journal of Neurophysiology
Published
1976-03-01
Volume
39
Issue
2
Pages
370-383
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2153815554
Cited by
300
References
0
FWCI
5.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor. https://app.cochat.ai/papers/10.1152/jn.1976.39.2.370
The paper
Elble, R. J., & Randall, J. E. (1976). Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor. Journal of Neurophysiology. https://doi.org/10.1152/jn.1976.39.2.370

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.