The DOI matches its Crossref record.
Complications from silicon‐polymer intubulation of nerves
Abstract
Three cases are reported to illustrate the potential danger of silicon—polymer intubulation of nerve for either nerve repair or following neurolysis. Since silicon‐polymer intubulation of nerve is now a proven model for producing chronic nerve compression, its use clinically may be contraindicated where neural regeneration is the desired goal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Monkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359
Materials for Peripheral Nerve Regeneration
Ciardelli, G., & Chiono, V. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200500151 · Cited by 255
Metadata
- Authors
- Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S.
- Venue
- Microsurgery
- Publisher
- Wiley
- Published
- 1989-01
- Volume
- 10
- Issue
- 2
- Pages
- 130-133
- ISSN
- 0738-1085 (ISSN-L)
- 1098-2752
- OpenAlex
- W2038997019
- Cited by
- 298
- References
- 0
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications from silicon‐polymer intubulation of nerves. https://app.cochat.ai/papers/10.1002/micr.1920100213
- The paper
- Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S. (1989). Complications from silicon‐polymer intubulation of nerves. Microsurgery. https://doi.org/10.1002/micr.1920100213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.