The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Monkey median nerve repaired by nerve graft or collagen nerve guide tube
Open accessAbstract
Nerve regeneration was followed in 15 median and 1 ulnar nerve of eight Macaca fascicularis monkeys by serial electrophysiological assessments over a period of three and a half years. Nerve gaps of 5 mm at the wrist were bridged by collagen-based nerve guides, nerve autografts, or direct suture repairs. Thenar muscle reinnervation occurred between 50 and 70 d for all groups, indicating axonal elongation rates of approximately 1 mm/d. The recovery rates of the compound muscle action potential (CMAP) and the compound sensory action potential (CSAP) amplitudes were significantly slower after direct suture repair compared to the other two procedures, although the final levels of recovery were all comparable. Similar results were achieved in one median and one ulnar nerve following nerve guide repair of a 15 mm nerve gap. The functional reinnervation of Pacinian corpuscles was detected in all cases following either nerve graft or nerve guide repair, with similar amplitudes and latencies of the tactile evoked CSAP for both types of repair. Histological analysis demonstrated a significant increase in the number of myelinated axons in the median nerve distal to the nerve lesions following both nerve graft and nerve guide repairs compared to proximal and normal controls, with significant reductions of fiber diameter and corresponding increases in g-ratio. The return of a bimodal frequency distribution of myelinated axon fiber diameter was confirmed by three-dimensional surface plots which illustrate the frequency distribution of the relationship between fiber diameter and g-ratio. These combined results demonstrate that nerve regeneration after repair of a 5 mm nerve gap with a collagen nerve guide in the nonhuman primate is similar to that after graft repair, and the final level of physiological recovery for both repair procedures is comparable to direct suture repair of the median nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evoked action potentials and conduction velocity in human sensory nerves
Buchthal, F., & Rosenfalck, A. (1966) · Brain Research · doi:10.1016/0006-8993(66)90056-4 · Cited by 756
Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Mackinnon, S. E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199003000-00015 · Cited by 535
Wound Healing: Biochemical and Clinical Aspects
Clay, R. P. (1993) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60711-3 · Cited by 534
Control of axonal caliber by neurofilament transport.
Hoffman, P. N., Griffin, J. W., & Price, D. L. (1984) · The Journal of cell biology · doi:10.1083/jcb.99.2.705 · Cited by 440
Recovery of fibre numbers and diameters in the regeneration of peripheral nerves
Gutmann, E., & Sanders, F. K. (1943) · The Journal of Physiology · doi:10.1113/jphysiol.1943.sp004002 · Cited by 397
Archibald, S. J., Krarup, C., Shefner, J., Li, S., & Madison, R. D. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903060410 · Cited by 374
Self-citationComposition of Peripheral Nerves
(1969) · Postgraduate Medical Journal · doi:10.1136/pgmj.45.525.459-a · Cited by 322
Nerve regeneration through artificial tubular implants
Fields, R. D., Le Beau, J. M., Longo, F. M., & Ellisman, M. H. (1989) · Progress in Neurobiology · doi:10.1016/0301-0082(89)90036-1 · Cited by 308
Complications from silicon‐polymer intubulation of nerves
Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S. (1989) · Microsurgery · doi:10.1002/micr.1920100213 · Cited by 298
An Alternative to the Classical Nerve Graft for the Management of the Short Nerve Gap
Dellon, A. L., & Mackinnon, S. E. (1988) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198811000-00020 · Cited by 292
Cited by
Current and Novel Polymeric Biomaterials for Neural Tissue Engineering
Boni, R., Ali, A., Shavandi, A., & Clarkson, A. N. (2018) · Journal of Biomedical Science · doi:10.1186/s12929-018-0491-8 · Cited by 439
Collagen—emerging collagen based therapies hit the patient
Abou Neel, E. A., Bozec, L., Knowles, J. C., Syed, O., Mudera, V., Day, R., & Hyun, J. K. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.010 · Cited by 296
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48
“Similar to previous studies (Jenq and Coggeshall, 1985; MacKinnon et al., 1991; Archibald et al., 1995), fiber counts within the conduits were significantly more numerous compared to controls.”
Result
Metadata
- Authors
- Archibald, S., Shefner, J., Krarup, C., & Madison, R.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1995-05-01
- Volume
- 15
- Issue
- 5
- Pages
- 4109-4123
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2154309821
- Cited by
- 359
- References
- 33
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monkey median nerve repaired by nerve graft or collagen nerve guide tube. https://app.cochat.ai/papers/10.1523/jneurosci.15-05-04109.1995
- The paper
- Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995). Monkey median nerve repaired by nerve graft or collagen nerve guide tube. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.15-05-04109.1995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.