CoChat

A computer‐aided diagnostic system for detecting diabetic retinopathy in optical coherence tomography images

ElTanboly, Ahmed, Ismail, Marwa, Shalaby, Ahmed, Switala, Andy, El‐Baz, Ayman, Schaal, Shlomit, Gimel’farb, Georgy, El‐Azab, Magdi · 2017 · Medical Physics
Cited by 117

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: Detection (diagnosis) of diabetic retinopathy (DR) in optical coherence tomography (OCT) images for patients with type 2 diabetes, but almost clinically normal retina appearances. Methods: The proposed computer‐aided diagnostic (CAD) system detects the DR in three steps: (a) localizing and segmenting 12 distinct retinal layers on the OCT image; (b) deriving features of the segmented layers, and (c) learning most discriminative features and classifying each subject as normal or diabetic. To localise and segment the retinal layers, signals (intensities) of the OCT image are described with a joint Markov‐Gibbs random field (MGRF) model of intensities and shape descriptors. Each segmented layer is characterized with cumulative probability distribution functions (CDF) of its locally extracted features, such as reflectivity, curvature, and thickness. A multistage deep fusion classification network (DFCN) with a stack of non‐negativity‐constrained autoencoders (NCAE) is trained to select the most discriminative retinal layers’ features and use their CDF s for detecting the DR. A training atlas was built using the OCT scans for 12 normal subjects and their maps of layers hand‐drawn by retina experts. Results: Preliminary experiments on 52 clinical OCT scans (26 normal and 26 with early‐stage DR, balanced between 40–79 yr old males and females; 40 training and 12 test subjects) gave the DR detection accuracy, sensitivity, and specificity of 92%; 83%, and 100%, respectively. The 100% accuracy, sensitivity, and specificity have been obtained in the leave‐one‐out cross‐validation test for all the 52 subjects. Conclusion: Both the quantitative and visual assessments confirmed the high accuracy of the proposed computer‐assisted diagnostic system for early DR detection using the OCT retinal images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.12071

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
ElTanboly, A., Ismail, M., Shalaby, A., Switala, A., El‐Baz, A., Schaal, S., Gimel’farb, G., & El‐Azab, M.
Venue
Medical Physics
Publisher
Wiley
Published
2017-03
Volume
44
Issue
3
Pages
914-923
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2564861555
Cited by
117
References
2
FWCI
8.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.