The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Evaluation of segmentation methods on head and neck CT: Auto‐segmentation challenge 2015
Open accessAbstract
Purpose: Automated delineation of structures and organs is a key step in medical imaging. However, due to the large number and diversity of structures and the large variety of segmentation algorithms, a consensus is lacking as to which automated segmentation method works best for certain applications. Segmentation challenges are a good approach for unbiased evaluation and comparison of segmentation algorithms. Methods: In this work, we describe and present the results of the Head and Neck Auto‐Segmentation Challenge 2015, a satellite event at the Medical Image Computing and Computer Assisted Interventions (MICCAI) 2015 conference. Six teams participated in a challenge to segment nine structures in the head and neck region of CT images: brainstem, mandible, chiasm, bilateral optic nerves, bilateral parotid glands, and bilateral submandibular glands. Results: This paper presents the quantitative results of this challenge using multiple established error metrics and a well‐defined ranking system. The strengths and weaknesses of the different auto‐segmentation approaches are analyzed and discussed. Conclusions: The Head and Neck Auto‐Segmentation Challenge 2015 was a good opportunity to assess the current state‐of‐the‐art in segmentation of organs at risk for radiotherapy treatment. Participating teams had the possibility to compare their approaches to other methods under unbiased and standardized circumstances. The results demonstrate a clear tendency toward more general purpose and fewer structure‐specific segmentation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cootes, T. F., Edwards, G. J., & Taylor, C. J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.927467 · Cited by 5,409
Cited by
Zhu, W., Huang, Y., Zeng, L., Chen, X., Liu, Y., Qian, Z., Du, N., Fan, W., & Xie, X. (2019) · Medical Physics · doi:10.1002/mp.13300 · Cited by 510
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Nikolov, S., Blackwell, S., Zverovitch, A., Mendes, R., Livne, M., De Fauw, J., Patel, Y., Meyer, C., Askham, H., Romera-Paredes, B., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/26151 · Cited by 366
Med3D: Transfer Learning for 3D Medical Image Analysis
Chen, S., Ma, K., & Zheng, Y. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.00625 · Cited by 317
Seo, H., Badiei Khuzani, M., Vasudevan, V., Huang, C., Ren, H., Xiao, R., Jia, X., & Xing, L. (2020) · Medical Physics · doi:10.1002/mp.13649 · Cited by 300
Metadata
- Authors
- Raudaschl, P. F., Zaffino, P., Sharp, G. C., Spadea, M. F., Chen, A., Dawant, B. M., Albrecht, T., Gass, T., Langguth, C., Lüthi, M., Jung, F., Knapp, O., Wesarg, S., Mannion‐Haworth, R., Bowes, M., Ashman, A., Guillard, G., Brett, A., Vincent, G., Orbes‐Arteaga, M., Cárdenas‐Peña, D., Castellanos‐Dominguez, G., Aghdasi, N., Li, Y., Berens, A., Moe, K., Hannaford, B., Schubert, R., & Fritscher, K. D.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2017-04-21
- Volume
- 44
- Issue
- 5
- Pages
- 2020-2036
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2593013519
- Cited by
- 259
- References
- 1
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.