Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated. However, it presents unique challenges for accurate planning and delivery especially in the lungs and upper abdomen where respiratory motion can be significantly confounding accurate targeting and avoidance of normal tissues. In this paper, we review the current literature on SBRT for lung and upper abdominal tumors with particular emphasis on addressing respiratory motion and its affects. We provide recommendations on strategies to manage motion for different, patient-specific situations. Some of the recommendations will potentially be adopted to guide clinical trial protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218 · cited 5×
“101 has provided recommendations for performing SBRT treatments including lung and upper abdominal tumors.(131) This present work provides additional recommendations for performing SBRT treatments for lung and upper abdominal tumors with potential adoption in clinical trial protocols for radiotherapy guidance.”
Influentialvan Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531 · cited 1×
“Margins added to the ITV to create the PTV must be designed with an understanding of the random and systematic setup uncertainties associated with patient setup.(127) Imaging frequency has an impact on margins.”
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379 · cited 6×
“Fluoroscopy is limited in that it cannot provide cross-sectional anatomical information, and it depends on high contrast for visualization such as implanted fiducials or soft tissue in lungs.(13) It is relatively quick, and in conjunction with IGRT localization, it may be used to confirm tumor or organ motion at the t…”
InfluentialThe use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 995 · cited 4×
“Breath-hold approaches include the ABC device where the lung volume is controlled and patients with tumors in the thorax or abdomen are treated with breath-hold near end inspiration.(81) ABC enables margin reduction and normal tissue sparing; however, the applicability to the general lung cancer population must be con…”
InfluentialOnishi, H., Shirato, H., Nagata, Y., Hiraoka, M., Fujino, M., 五味, 光., Niibe, Y., Karasawa, K., Hayakawa, K., Takai, Y., et al. (2007) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318074de34 · Cited by 989
Chetty, I. J., Curran, B. H., Cygler, J., DeMarco, J. J., Ezzell, G. A., Faddegon, B., Kawrakow, I., Keall, P., Liu, H. W., Ma, C., et al. (2007) · Medical Physics · doi:10.1118/1.2795842 · Cited by 849 · cited 1×
“This results in reduced central axis dose to the tumor and smearing of the edges of the dose profile.(143) When coupled with tumor motion (which tends to smear out dose distributions) the reduction in the tumor dose and in the coverage of the extent of the tumor can be significant.”
Self-citationBaumann, P., Nyman, J., Hoyer, M., Wennberg, B., Gagliardi, G., Lax, I., Drugge, N., Ekberg, L., Friesland, S., Johansson, K.-A., et al. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.21.5681 · Cited by 836
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 699
Hanley, J., Debois, M. M., Mah, D. W., Mageras, G. S., Raben, A., Rosenzweig, K. E., Mychalczak, B. R., Schwartz, L. H., Gloeggler, P. J., Lutz, W. R., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00154-6 · Cited by 671
Cited by
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
“aspect of treatment protocols at many centres [43].”
Background
Metadata
- Authors
- Brandner, E. D., Chetty, I. J., Giaddui, T. G., Xiao, Y., & Huq, M. S.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2017-04-20
- Volume
- 44
- Issue
- 6
- Pages
- 2595-2612
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2600896084
- Cited by
- 194
- References
- 49
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. https://app.cochat.ai/papers/10.1002/mp.12227
- The paper
- Brandner, E. D., Chetty, I. J., Giaddui, T. G., Xiao, Y., & Huq, M. S. (2017). Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. Medical Physics. https://doi.org/10.1002/mp.12227
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.