Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated. However, it presents unique challenges for accurate planning and delivery especially in the lungs and upper abdomen where respiratory motion can be significantly confounding accurate targeting and avoidance of normal tissues. In this paper, we review the current literature on SBRT for lung and upper abdominal tumors with particular emphasis on addressing respiratory motion and its affects. We provide recommendations on strategies to manage motion for different, patient-specific situations. Some of the recommendations will potentially be adopted to guide clinical trial protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218 · cited 5×
“101 has provided recommendations for performing SBRT treatments including lung and upper abdominal tumors.(131) This present work provides additional recommendations for performing SBRT treatments for lung and upper abdominal tumors with potential adoption in clinical trial protocols for radiotherapy guidance.”
Influentialvan Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531 · cited 1×
“Margins added to the ITV to create the PTV must be designed with an understanding of the random and systematic setup uncertainties associated with patient setup.(127) Imaging frequency has an impact on margins.”
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379 · cited 6×
“Fluoroscopy is limited in that it cannot provide cross-sectional anatomical information, and it depends on high contrast for visualization such as implanted fiducials or soft tissue in lungs.(13) It is relatively quick, and in conjunction with IGRT localization, it may be used to confirm tumor or organ motion at the t…”
InfluentialThe use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 995 · cited 4×
“Breath-hold approaches include the ABC device where the lung volume is controlled and patients with tumors in the thorax or abdomen are treated with breath-hold near end inspiration.(81) ABC enables margin reduction and normal tissue sparing; however, the applicability to the general lung cancer population must be con…”
InfluentialOnishi, H., Shirato, H., Nagata, Y., Hiraoka, M., Fujino, M., 五味, 光., Niibe, Y., Karasawa, K., Hayakawa, K., Takai, Y., et al. (2007) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318074de34 · Cited by 989
Chetty, I. J., Curran, B. H., Cygler, J., DeMarco, J. J., Ezzell, G. A., Faddegon, B., Kawrakow, I., Keall, P., Liu, H. W., Ma, C., et al. (2007) · Medical Physics · doi:10.1118/1.2795842 · Cited by 849 · cited 1×
“This results in reduced central axis dose to the tumor and smearing of the edges of the dose profile.(143) When coupled with tumor motion (which tends to smear out dose distributions) the reduction in the tumor dose and in the coverage of the extent of the tumor can be significant.”
Self-citationBaumann, P., Nyman, J., Hoyer, M., Wennberg, B., Gagliardi, G., Lax, I., Drugge, N., Ekberg, L., Friesland, S., Johansson, K.-A., et al. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.21.5681 · Cited by 836
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 699
Hanley, J., Debois, M. M., Mah, D. W., Mageras, G. S., Raben, A., Rosenzweig, K. E., Mychalczak, B. R., Schwartz, L. H., Gloeggler, P. J., Lutz, W. R., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00154-6 · Cited by 671
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
4-dimensional computed tomography imaging and treatment planning
KEALL, P. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.006 · Cited by 484 · cited 1×
“Irregular respiration makes the acquisition of high-quality 4D CT images very challenging.(45) The method of binning the CT images based on the respiratory signal can affect the quality of the 4D CT images.”
Shirato, H., Shimizu, S., Kitamura, K., Nishioka, T., Kagei, K., Hashimoto, S., Aoyama, H., Kunieda, T., Shinohara, N., Dosaka-Akita, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00625-8 · Cited by 464
Purdie, T. G., Bissonnette, J., Franks, K., Bezjak, A., Payne, D. G., Sie, F., Sharpe, M. B., & Jaffray, D. A. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.022 · Cited by 371
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S. (2012) · Medical Physics · doi:10.1118/1.3690466 · Cited by 359 · cited 2×
“The in-room CT image can be aligned with the reference CT (planning CT) based on soft tissue and bony contrast.(28,168) CT-on-rails has the advantage of more consistent and accurate registration with the planning CT as compared with CBCT,(168) and it allows image guided adaptive radiotherapy by modifying the treatment…”
Issues in respiratory motion compensation during external-beam radiotherapy
Ozhasoglu, C., & Murphy, M. J. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)02789-4 · Cited by 356 · cited 4×
“The Synchrony Respiratory Tracking System (Accuray Oncology, Sunnyvale, CA, USA) correlates external markers with orthogonal stereoscopic images of fiducials implanted in or near the target volume to create a model of the target motion.(63,85) The model is then used to move the CyberKnife robotic linear accelerator to…”
InfluentialFour‐dimensional (4D) PET/CT imaging of the thorax
Nehmeh, S. A., Erdi, Y. E., Pan, T., Pevsner, A., Rosenzweig, K. E., Yorke, E., Mageras, G. S., Schoder, H., Vernon, P., Squire, O., et al. (2004) · Medical Physics · doi:10.1118/1.1809778 · Cited by 349
Image-guided radiotherapy: rationale, benefits, and limitations
Dawson, L. A., & Sharpe, M. B. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70904-4 · Cited by 341 · cited 1×
“The model is then used to move the CyberKnife robotic linear accelerator to track the target, and periodically additional x-ray images are acquired to verify and/or update the target motion model.(85,106)”
Correlation of lung tumor motion with external surrogate indicators of respiration
Hoisak, J. D. P., Sixel, K. E., Tirona, R., Cheung, P. C. F., & Pignol, J.-P. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.07.681 · Cited by 318 · cited 1×
“77 in one case).(114) None of these studies included coaching.”
Underberg, R. W. M., Lagerwaard, F. J., Slotman, B. J., Cuijpers, J. P., & Senan, S. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.05.045 · Cited by 315
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Squire, O. D., Braban, L. E., Ford, E., Sidhu, K., Mageras, G. S., Larson, S. M., et al. (2002) · Medical Physics · doi:10.1118/1.1448824 · Cited by 297
Videtic, G. M., Paulus, R., Singh, A. K., Chang, J. Y., Parker, W., Olivier, K. R., Timmerman, R. D., Komaki, R. R., Urbanic, J. J., Stephans, K. L., et al. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.11.051 · Cited by 294
Breathing pattern in humans: diversity and individuality
Benchetrit, G. (2000) · Respiration Physiology · doi:10.1016/s0034-5687(00)00154-7 · Cited by 288
Yamamoto, T., Langner, U., Loo, B. W., Shen, J., & Keall, P. J. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.06.1937 · Cited by 280 · cited 1×
“Respiratory motion, if not taken into consideration, leads to artifacts and uncertainties in imaging and consequently affects the whole treatment process diminishing the accuracy of radiation therapy during imaging, planning, and treatment delivery.(10) Subsequently, these effects on planning and diagnostic images lea…”
George, R., Chung, T. D., Vedam, S. S., Ramakrishnan, V., Mohan, R., Weiss, E., & Keall, P. J. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.02.035 · Cited by 243 · cited 5×
“Phase-based gating is easier to coach, but the most recent studies suggest that amplitude-based gating has less residual motion.(66,89,96) As was already noted in an imaging study, Abdelnour et al.”
InfluentialGrills, I. S., Hugo, G., Kestin, L. L., Galerani, A. P., Chao, K. K., Wloch, J., & Yan, D. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.07.2352 · Cited by 237 · cited 1×
“Daily IGRT-based setup has been shown to significantly reduce residual uncertainties and consequently planning margins.(129,130)”
Quantitation of respiratory motion during 4D‐PET/CT acquisition
Nehmeh, S. A., Erdi, Y. E., Pan, T., Yorke, E., Mageras, G. S., Rosenzweig, K. E., Schoder, H., Mostafavi, H., Squire, O., Pevsner, A., et al. (2004) · Medical Physics · doi:10.1118/1.1739671 · Cited by 232
Langbecker, D., & Janda, M. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00001 · Cited by 228
Senan, S., De Ruysscher, D., Giraud, P., Mirimanoff, R., & Budach, V. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2003.09.007 · Cited by 222
Internal‐external correlation investigations of respiratory induced motion of lung tumors
Ionascu, D., Jiang, S. B., Nishioka, S., Shirato, H., & Berbeco, R. I. (2007) · Medical Physics · doi:10.1118/1.2779941 · Cited by 209 · cited 1×
“abdomen of each patient could localize the internal targets to within 5 mm.(112) Likewise, Koch et al.”
Guest Editor's Introduction to QUANTEC: A Users Guide
Marks, L. B., Haken, R. K. T., & Martel, M. K. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.08.075 · Cited by 208
Abdominal organ motion measured using 4D CT
Brandner, E. D., Wu, A., Chen, H., Heron, D., Kalnicki, S., Komanduri, K., Gerszten, K., Burton, S., Ahmed, I., & Shou, Z. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.12.042 · Cited by 184 · cited 1×
“However, organs in the upper abdomen such as the liver, kidneys, and spleen move significantly as a result of respiration—typically more than 10 mm.(23,24)”
Self-citationImage-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy
Stemkens, B., Tijssen, R. H. N., de Senneville, B. D., Lagendijk, J. J. W., & van den Berg, C. A. T. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/14/5335 · Cited by 151
Phase and amplitude binning for 4D-CT imaging
Abdelnour, A. F., Nehmeh, S. A., Pan, T., Humm, J. L., Vernon, P., Schöder, H. M., Rosenzweig, K., Mageras, G. S., Yorke, E. D., Larson, S. M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/012 · Cited by 150 · cited 3×
“found that amplitude-based binning was more consistent and accurate than phase-based binning.(46) In a study of 24 patients, George et al.”
InfluentialGe, J., Santanam, L., Noel, C. E., & Parikh, P. J. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2012.09.014 · Cited by 136
Ezhil, M., Vedam, S. S., Balter, P. A., Choi, B., Mirković, D., Starkschall, G., & Chang, J. Y. (2009) · Radiation Oncology · doi:10.1186/1748-717x-4-4 · Cited by 104 · cited 5×
“Automatic tools have been developed to improve efficiency in the contouring of GTVs on multiple datasets to form an IGTV and the ITV.”
InfluentialHeerkens, H. D., van Vulpen, M., van den Berg, C. A. T., Tijssen, R. H. N., Crijns, S. P. M., Molenaar, I. Q., van Santvoort, H. C., Reerink, O., & Meijer, G. J. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.03.002 · Cited by 85 · cited 2×
“It was found that gated deliveries for radiotherapy of pancreatic cancer is best performed around the end-exhale position and that motion patterns and motion amplitude differ substantially between individual patients.(49) Cine MRI images have been used to detect larger differences in hepatic intrafraction tumor motion…”
Stereotactic body radiation therapy for liver metastases.
Scorsetti, M., Clerici, E., & Comito, T. (2014) · PubMed Central · doi:10.3978/j.issn.2078-6891.2014.039 · Cited by 84
Inter-fraction variations in respiratory motion models
McClelland, J. R., Hughes, S. R., Marc Modat, A., Qureshi, A., Ahmad, S., Landau, D., Sebastien Ourselin, A., & Hawkes, D. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/015 · Cited by 83
Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
Shirato, H., Shimizu, S., Kitamura, K., & Onimaru, R. (2007) · International Journal of Clinical Oncology · doi:10.1007/s10147-006-0633-y · Cited by 70 · cited 1×
“When gating is used for treatment, margins can generally be reduced and some groups have thus defined the PTV as CTV + 5 mm.(120,136,137) A margin expansion of a few millimeters is necessary to account for residual tumor motion and setup uncertainty.”
Do Maximum Intensity Projection Images Truly Capture Tumor Motion?
Park, K., Huang, L., Gagne, H., & Papiez, L. S. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.10.008 · Cited by 69 · cited 1×
“found MIP images to be accurate to within 2–3 mm of the real target motion span for regular (constant amplitude and period) target motions but could under-represent the motion span by more than 10 mm for irregular motion.(62) Tian et al.”
Higgins, J., Bezjak, A., Hope, A. J., Panzarella, T., Li, W. W., Cho, J. B. C., Craig, T., Brade, A. M., Sun, A. Y., & Bissonnette, J. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.04.006 · Cited by 64 · cited 1×
“They derived setup margins of 3–4 mm if daily CBCT was used versus 5–9 mm if CBCT was done less often than every fraction.(166)”
Advances in 4D radiation therapy for managing respiration: Part I – 4D imaging
Hugo, G. D., & Roşu, M. O. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.06.009 · Cited by 62 · cited 1×
“Respiration is quasi periodic with a relatively predictable pattern for each patient.(11) Respiratory motion is patient specific,(12) and respiratory characteristics may vary in period, amplitude, and regularity.”
Glide‐Hurst, C. K., & Chetty, I. J. (2014) · PubMed · doi:10.3978/j.issn.2072-1439.2013.11.10 · Cited by 52 · cited 13×
“, implanted fiducials can be used to track tumor and/ or critical structure motion; however, such invasive procedures have inherent risks and cannot always be used.(85) A technique that improves breathing reproducibility would improve the monitoring and evaluation of respiration.”
InfluentialSelf-citationPaganelli, C., Seregni, M., Fattori, G., Summers, P. E., Bellomi, M., Baroni, G., & Riboldi, M. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.12.013 · Cited by 50
Rietzel, E., Liu, A. K., Chen, G. T. Y., & Choi, N. C. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.03.030 · Cited by 47 · cited 1×
“Studies have shown the MIP to be an effective tool for automatic contouring of targets on multiple phases of the 4D-CT but caution that the MIP should be validated against the ITV formed by contours on each of the respiratory-correlated CT datasets.(152) Other studies point out that the MIP cannot be used for tumors l…”
Evolution of motion uncertainty in rectal cancer: implications for adaptive radiotherapy
Kleijnen, J.-P., van Asselen, B., Burbach, J. P. M., Intven, M., Philippens, M. E. P., Reerink, O., Lagendijk, J. J. W., & Raaymakers, B. W. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/1 · Cited by 41
Kidney motion during free breathing and breath hold for MR-guided radiotherapy
Stam, M. K., van Vulpen, M., Barendrecht, M. M., et al. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/7/2235 · Cited by 30 · cited 1×
“Furthermore, most people generally spend more time near end expiration than near any other phase.(13,67,69) Therefore, the end expiration phase or CT50 is often used for contouring, planning, and evaluation.”
Yang, Y. X., Teo, S.-K., Reeth, É. V., Tan, C. H., Tham, I. W. K., & Poh, C. L. (2015) · Medical Physics · doi:10.1118/1.4923167 · Cited by 25
Cited by
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
“aspect of treatment protocols at many centres [43].”
Background
Metadata
- Authors
- Brandner, E. D., Chetty, I. J., Giaddui, T. G., Xiao, Y., & Huq, M. S.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2017-04-20
- Volume
- 44
- Issue
- 6
- Pages
- 2595-2612
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2600896084
- Cited by
- 194
- References
- 49
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.