CoChat

Development of deep neural network for individualized hepatobiliary toxicity prediction after liver SBRT

Open access
Ibragimov, Bulat, Toesca, Diego, Chang, Daniel, Yuan, Yixuan, Koong, Albert, Xing, Lei · 2018 · Medical Physics
Cited by 125

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Accurate prediction of radiation toxicity of healthy organs‐at‐risks (OAR s) critically determines the radiation therapy (RT) success. The existing dose–volume histogram‐based metric may grossly under/overestimate the therapeutic toxicity after 27% in liver RT and 50% in head‐and‐neck RT. We propose the novel paradigm for toxicity prediction by leveraging the enormous potential of deep learning and go beyond the existing dose/volume histograms. Experimental Design: We employed a database of 125 liver stereotactic body RT (SBRT) cases with follow‐up data to train deep learning‐based toxicity predictor. Convolutional neural networks (CNN s) were applied to discover the consistent patterns in 3D dose plans associated with toxicities. To enhance the predicting power, we first pretrain the CNN s with transfer learning from 3D CT images of 2644 human organs. CNN s were then trained on liver SBRT cases. Furthermore, nondosimetric pretreatment features, such as patients’ demographics, underlying liver diseases, liver‐directed therapies, were inputted into the fully connected neural network for more comprehensive prediction. The saliency maps of CNN s were used to estimate the toxicity risks associated with irradiation of anatomical regions of specific OAR s. In addition, we applied machine learning solutions to map numerical pretreatment features with hepatobiliary toxicity manifestation. Results: Among 125 liver SBRT patients, 58 were treated for liver metastases, 36 for hepatocellular carcinoma, 27 for cholangiocarcinoma, and 4 for other histologies. We observed that CNN we able to achieve accurate hepatobiliary toxicity prediction with the AUC of 0.79, whereas combining CNN for 3D dose plan analysis and fully connected neural networks for numerical feature analysis resulted in AUC of 0.85. Deep learning produces almost two times fewer false‐positive toxicity predictions in comparison to DVH‐based predictions, when the number of false negatives, i.e., missed toxicities, was minimized. The CNN saliency maps automatically estimated the toxicity risks for portal vein (PV) regions. We discovered that irradiation of the proximal portal vein is associated with two times higher toxicity risks (risk score: 0.66) that irradiation of the left portal vein (risk score: 0.31). Conclusions: The framework offers clinically accurate tools for hepatobiliary toxicity prediction and automatic identification of anatomical regions that are critical to spare during SBRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13122

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Ibragimov, B., Toesca, D., Chang, D., Yuan, Y., Koong, A., & Xing, L.
Venue
Medical Physics
Publisher
Wiley
Published
2018-09-10
Volume
45
Issue
10
Pages
4763-4774
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2885185546
Cited by
125
References
6
FWCI
12.49
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.