Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 510

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

AnatomyNet: Deep learning for fast and fully automated whole‐volume segmentation of head and neck anatomy

Open access
Zhu, Wentao, Huang, Yufang, Zeng, Liang, Chen, Xuming, Liu, Yong, Qian, Zhen, Du, Nan, Fan, Wei, Xie, Xiaohui·2019·Medical Physics

Abstract

Purpose: Radiation therapy (RT) is a common treatment option for head and neck (HaN) cancer. An important step involved in RT planning is the delineation of organs‐at‐risks (OARs) based on HaN computed tomography (CT). However, manually delineating OARs is time‐consuming as each slice of CT images needs to be individually examined and a typical CT consists of hundreds of slices. Automating OARs segmentation has the benefit of both reducing the time and improving the quality of RT planning. Existing anatomy autosegmentation algorithms use primarily atlas‐based methods, which require sophisticated atlas creation and cannot adequately account for anatomy variations among patients. In this work, we propose an end‐to‐end, atlas‐free three‐dimensional (3D) convolutional deep learning framework for fast and fully automated whole‐volume HaN anatomy segmentation. Methods: Our deep learning model, called AnatomyNet, segments OARs from head and neck CT images in an end‐to‐end fashion, receiving whole‐volume HaN CT images as input and generating masks of all OARs of interest in one shot. AnatomyNet is built upon the popular 3D U‐net architecture, but extends it in three important ways: (a) a new encoding scheme to allow autosegmentation on whole‐volume CT images instead of local patches or subsets of slices, (b) incorporating 3D squeeze‐and‐excitation residual blocks in encoding layers for better feature representation, and (c) a new loss function combining Dice scores and focal loss to facilitate the training of the neural model. These features are designed to address two main challenges in deep learning‐based HaN segmentation: (a) segmenting small anatomies (i.e., optic chiasm and optic nerves) occupying only a few slices, and (b) training with inconsistent data annotations with missing ground truth for some anatomical structures. Results: We collected 261 HaN CT images to train AnatomyNet and used MICCAI Head and Neck Auto Segmentation Challenge 2015 as a benchmark dataset to evaluate the performance of AnatomyNet. The objective is to segment nine anatomies: brain stem, chiasm, mandible, optic nerve left, optic nerve right, parotid gland left, parotid gland right, submandibular gland left, and submandibular gland right. Compared to previous state‐of‐the‐art results from the MICCAI 2015 competition, AnatomyNet increases Dice similarity coefficient by 3.3% on average. AnatomyNet takes about 0.12 s to fully segment a head and neck CT image of dimension 178 × 302 × 225, significantly faster than previous methods. In addition, the model is able to process whole‐volume CT images and delineate all OARs in one pass, requiring little pre‐ or postprocessing. Conclusion: Deep learning models offer a feasible solution to the problem of delineating OARs from CT images. We demonstrate that our proposed model can improve segmentation accuracy and simplify the autosegmentation pipeline. With this method, it is possible to delineate OARs of a head and neck CT within a fraction of a second.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13300

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

Metadata

Authors
Zhu, W., Huang, Y., Zeng, L., Chen, X., Liu, Y., Qian, Z., Du, N., Fan, W., & Xie, X.
Venue
Medical Physics
Publisher
Wiley
Published
2018-12-17
Volume
46
Issue
2
Pages
576-589
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2900237898
Cited by
510
References
41
FWCI
27.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.