CoChat

A deep learning method for prediction of three‐dimensional dose distribution of helical tomotherapy

Liu, Zhiqiang, Fan, Jiawei, Li, Minghui, Yan, Hui, Hu, Zhihui, Huang, Peng, Tian, Yuan, Miao, Junjie, Dai, Jianrong · 2019 · Medical Physics
Cited by 123

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Purpose: To develop a deep learning method for prediction of three‐dimensional (3D) voxel‐by‐voxel dose distributions of helical tomotherapy (HT). Methods: Using previously treated HT plans as training data, a deep learning model named U‐ResNet‐D was trained to predict a 3D dose distribution. First, the contoured structures and dose volumes were converted from plan database to 3D matrix with a program based on a developed visualization toolkit (VTK), then transferred to U‐ResNet‐D for correlating anatomical features and dose distributions at voxel‐level. One hundred and ninety nasopharyngeal cancer (NPC) patients treated by HT with multiple planning target volumes (PTVs) in different prescription patterns were studied. The model was typically trained from scratch with weights randomly initialized rather than using transfer‐learning method, and used to predict new patient's 3D dose distributions. The predictive accuracy was evaluated with three methods: (a) The dose difference at the position r, δ(r, r) = Dc(r) − Dp(r), was calculated for each voxel. The mean (μδ(r,r)) and standard deviation (σδ(r,r)) of δ(r, r) were calculated to assess the prediction bias and precision; (b) The mean absolute differences of dosimetric indexes (DIs) including maximum and mean dose, homogeneity index, conformity index, and dose spillage for PTVs and organ at risks (OARs) were calculated and statistically analyzed with the paired‐samples t test; (c) Dice similarity coefficients (DSC) between predicted and clinical isodose volumes were calculated. Results: The U‐ResNet‐D model predicted 3D dose distribution accurately. For twenty tested patients, the prediction bias ranged from −2.0% to 2.3% and prediction error varied from 1.5% to 4.5% (relative to prescription) for 3D dose differences. The mean absolute dose differences for PTVs and OARs are within 2.0% and 4.2%, and nearly all the DIs for PTVs and OARs had no significant differences. The averaged DSC ranged from 0.95 to 1 for different isodose volumes. Conclusions: The study developed a new deep learning method for 3D voxel‐by‐voxel dose prediction, and shown to be able to produce accurately dose predictions for nasopharyngeal patients treated by HT. The predicted 3D dose map can be useful for improving radiotherapy planning design, ensuring plan quality and consistency, making clinical technique comparison, and guiding automatic treatment planning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13490

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Liu, Z., Fan, J., Li, M., Yan, H., Hu, Z., Huang, P., Tian, Y., Miao, J., & Dai, J.
Venue
Medical Physics
Publisher
Wiley
Published
2019-03-30
Volume
46
Issue
5
Pages
1972-1983
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2921903201
Cited by
123
References
9
FWCI
11.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.