The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Knowledge‐based planning for intensity‐modulated radiation therapy: A review of data‐driven approaches
Open accessAbstract
Purpose: Intensity‐Modulated Radiation Therapy (IMRT), including its variations (including IMRT, Volumetric Arc Therapy (VMAT), and Tomotherapy), is a widely used and critically important technology for cancer treatment. It is a knowledge‐intensive technology due not only to its own technical complexity, but also to the inherently conflicting nature of maximizing tumor control while minimizing normal organ damage. As IMRT experience and especially the carefully designed clinical plan data are accumulated during the past two decades, a new set of methods commonly termed knowledge‐based planning (KBP) have been developed that aim to improve the quality and efficiency of IMRT planning by learning from the database of past clinical plans. Some of this development has led to commercial products recently that allowed the investigation of KBP in numerous clinical applications. In this literature review, we will attempt to present a summary of published methods of knowledge‐based approaches in IMRT and recent clinical validation results. Methods: In March 2018, a literature search was conducted in the NIH Medline database using the PubMed interface to identify publications that describe methods and validations related to KBP in IMRT including variations such as VMAT and Tomotherapy. The search criteria were designed to have a broad scope to capture relevant results with high sensitivity. The authors filtered down the search results according to a predefined selection criteria by reviewing the titles and abstracts first and then by reviewing the full text. A few papers were added to the list based on the references of the reviewed papers. The final set of papers was reviewed and summarized here. Results: The initial search yielded a total of 740 articles. A careful review of the titles, abstracts, and eventually the full text and then adding relevant articles from reviewing the references resulted in a final list of 73 articles published between 2011 and early 2018. These articles described methods for developing knowledge models for predicting such parameters as dosimetric and dose‐volume points, voxel‐level doses, and objective function weights that improve or automate IMRT planning for various cancer sites, addressing different clinical and quality assurance needs, and using a variety of machine learning approaches. A number of articles reported carefully designed clinical studies that assessed the performance of KBP models in realistic clinical applications. Overwhelming majority of the studies demonstrated the benefits of KBP in achieving comparable and often improved quality of IMRT planning while reducing planning time and plan quality variation. Conclusions: The number of KBP‐related studies has been steadily increasing since 2011 indicating a growing interest in applying this approach to clinical applications. Validation studies have generally shown KBP to produce plans with quality comparable to expert planners while reducing the time and efforts to generate plans. However, current studies are mostly retrospective and leverage relatively small datasets. Larger datasets collected through multi‐institutional collaboration will enable the development of more advanced models to further improve the performance of KBP in complex clinical cases. Prospective studies will be an important next step toward widespread adoption of this exciting technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.006 · Cited by 10,578
Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning
Appenzoller, L. M., Michalski, J. M., Thorstad, W. L., Mutic, S., & Moore, K. L. (2012) · Medical Physics · doi:10.1118/1.4761864 · Cited by 382
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J. (2011) · Medical Physics · doi:10.1118/1.3539749 · Cited by 324
Self-citationYuan, L., Ge, Y., Lee, W. R., Yin, F. F., Kirkpatrick, J. P., & Wu, Q. J. (2012) · Medical Physics · doi:10.1118/1.4757927 · Cited by 285
Self-citationEvaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer
Tol, J. P., Delaney, A. R., Dahele, M., Slotman, B. J., & Verbakel, W. F. A. R. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.11.014 · Cited by 279
Wu, B., Ricchetti, F., Sanguineti, G., Kazhdan, M., Simari, P., Jacques, R., Taylor, R., & McNutt, T. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.026 · Cited by 260
Shiraishi, S., & Moore, K. L. (2015) · Medical Physics · doi:10.1118/1.4938583 · Cited by 237
Good, D., Lo, J., Lee, W. R., Wu, Q. J., Yin, F.-F., & Das, S. K. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.03.015 · Cited by 235
Self-citationA mathematical framework for virtual IMRT QA using machine learning
Valdes, G., Scheuermann, R., Hung, C. Y., Olszanski, A., Bellerive, M., & Solberg, T. D. (2016) · Medical Physics · doi:10.1118/1.4953835 · Cited by 193
Knowledge-based IMRT treatment planning for prostate cancer
Chanyavanich, V., Das, S. K., Lee, W. R., & Lo, J. Y. (2011) · Medical Physics · doi:10.1118/1.3574874 · Cited by 190
McIntosh, C., Welch, M., McNiven, A., Jaffray, D. A., & Purdie, T. G. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa71f8 · Cited by 190
IMRT QA using machine learning: A multi‐institutional validation
Valdes, G., Chan, M. F., Lim, S. B., Scheuermann, R., Deasy, J. O., & Solberg, T. D. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12161 · Cited by 164
Chang, A. T. Y., Hung, A. W. M., Cheung, F. W. K., Lee, M. C. H., Chan, O. S. H., Philips, H., Cheng, Y.-T., & Ng, W. T. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.02.017 · Cited by 153
Valdés, G., Simone, C. B., Chen, J., Lin, A., Yom, S. S., Pattison, A. J., Carpenter, C. M., & Solberg, T. D. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.10.014 · Cited by 111
Zarepisheh, M., Long, T., Li, N., Tian, Z., Romeijn, H. E., Jia, X., & Jiang, S. B. (2014) · Medical Physics · doi:10.1118/1.4875700 · Cited by 108
A methodology for automatic intensity-modulated radiation treatment planning for lung cancer
Zhang, X., Li, X., Quan, E., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/13/009 · Cited by 105
Knowledge‐based automated planning for oropharyngeal cancer
Babier, A., Boutilier, J. J., McNiven, A., & Chan, T. C. Y. (2018) · Medical Physics · doi:10.1002/mp.12930 · Cited by 97
Yang, Y., Ford, E. C., Wu, B., Pinkawa, M., van Triest, B., Campbell, P. H., Song, D. Y., & McNutt, T. (2012) · Medical Physics · doi:10.1118/1.4769424 · Cited by 96
McIntosh, C., & Purdie, T. G. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2505188 · Cited by 95
Wu, B., McNutt, T., ZAHURAK, M. L., Simari, P. D., Pang, D., Taylor, R. H., & Sanguineti, G. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2012.06.047 · Cited by 94
McIntosh, C., & Purdie, T. G. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/2/415 · Cited by 79
Schubert, C., Waletzko, O., Weiß, C., Völzke, D., Toperim, S., Röser, A., Puccini, S., Piroth, M. D., Mehrens, C., Kueter, J.-D., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178034 · Cited by 79
Fogliata, A., Nicolini, G., Bourgier, C., Clivio, A., Rose, F. D., Fenoglietto, P., Lobefalo, F., Mancosu, P., Tomatis, S., Vanetti, E., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0145137 · Cited by 75
Neural network dose models for knowledge‐based planning in pancreatic SBRT
Campbell, W. G., Miften, M., Olsen, L., Stumpf, P., Schefter, T. E., Goodman, K. A., & Jones, B. L. (2017) · Medical Physics · doi:10.1002/mp.12621 · Cited by 74
Wang, J., Hu, W., Yang, Z., Chen, X., Wu, Z., Yu, X., Guo, X., Lu, S., Li, K., & Yu, G. (2017) · Radiation Oncology · doi:10.1186/s13014-017-0822-z · Cited by 72
Models for predicting objective function weights in prostate cancer IMRT
Boutilier, J. J., Lee, T., Craig, T., Sharpe, M. B., & Chan, T. C. Y. (2015) · Medical Physics · doi:10.1118/1.4914140 · Cited by 69
Sample size requirements for knowledge‐based treatment planning
Boutilier, J. J., Craig, T., Sharpe, M. B., & Chan, T. C. Y. (2016) · Medical Physics · doi:10.1118/1.4941363 · Cited by 63
Knowledge-light adaptation approaches in case-based reasoning for radiotherapy treatment planning
Petrović, S., Khussainova, G., & Jagannathan, R. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.01.006 · Cited by 49
An analysis of knowledge-based planning for stereotactic body radiation therapy of the spine
Foy, J. J., Marsh, R., Haken, R. K. T., Younge, K. C., Schipper, M. J., Sun, Y., Owen, D., & Matuszak, M. M. (2017) · Practical Radiation Oncology · doi:10.1016/j.prro.2017.02.007 · Cited by 46
Fan, J., Wang, J., Zhang, Z., & Hu, W. (2017) · Medical Physics · doi:10.1002/mp.12232 · Cited by 40
An Ensemble Approach to Knowledge-Based Intensity-Modulated Radiation Therapy Planning
Zhang, J., Wu, Q., Xie, T., Sheng, Y., Yin, F.-F., & Ge, Y. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00057 · Cited by 37
Self-citationOutlier identification in radiation therapy knowledge‐based planning: A study of pelvic cases
Sheng, Y., Ge, Y., Yuan, L., Li, T., Yin, F.-F., & Wu, Q. J. (2017) · Medical Physics · doi:10.1002/mp.12556 · Cited by 32
Self-citationBrown, W. E., Sung, K., Aleman, D. M., Moreno‐Centeno, E., Purdie, T. G., & McIntosh, C. (2018) · Medical Physics · doi:10.1002/mp.12757 · Cited by 17
Deshpande, R., DeMarco, J. J., Sayre, J. W., & Liu, B. J. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1403-6 · Cited by 14
Cooper, B. T., Li, X., Shin, S. M., Modrek, A. S., Hsu, H. C., DeWyngaert, J. K., Jozsef, G., Lymberis, S. C., Goldberg, J. D., & Formenti, S. C. (2016) · Advances in Radiation Oncology · doi:10.1016/j.adro.2016.08.001 · Cited by 13
Kuo, L., Yorke, E. D., Dumane, V. A., Foster, A., Zhang, Z., Mechalakos, J., Wu, A. J.-C., Rosenzweig, K. E., & Rimner, A. (2016) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v17i3.6199 · Cited by 8
Cited by
Application of Radiosensitizers in Cancer Radiotherapy
Gong, L., Zhang, Y., Liu, C., Zhang, M., & Han, S. (2021) · International Journal of Nanomedicine · doi:10.2147/ijn.s290438 · Cited by 479
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Barragán-Montero, A. M., Thomas, M., Defraene, G., Michiels, S., Haustermans, K., Lee, J. A., & Sterpin, E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.026 · Cited by 69
Artificial intelligence in radiotherapy
Li, G., Wu, X., & Ma, X. (2022) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2022.08.005 · Cited by 46
Metadata
- Authors
- Ge, Y., & Wu, Q. J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2019-04-24
- Volume
- 46
- Issue
- 6
- Pages
- 2760-2775
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2939627886
- Cited by
- 259
- References
- 38
- FWCI
- 23.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.