Purpose: To investigate two deep learning‐based modeling schemes for predicting short‐term risk of developing breast cancer using prior normal screening digital mammograms in a case‐control setting. Methods: We conducted a retrospective Institutional Review Board‐approved study on a case‐control cohort of 226 patients (including 113 women diagnosed with breast cancer and 113 controls) who underwent general population breast cancer screening. For each patient, a prior normal (i.e., with negative or benign findings) digital mammogram examination [including mediolateral oblique (MLO) view and craniocaudal (CC) view two images] was collected. Thus, a total of 452 normal images (226 MLO view images and 226 CC view images) of this case‐control cohort were analyzed to predict the outcome, i.e., developing breast cancer (cancer cases) or remaining breast cancer‐free (controls) within the follow‐up period. We implemented an end‐to‐end deep learning model and a GoogLeNet‐LDA model and compared their effects in several experimental settings using two mammographic view images and inputting two different subregions of the images to the models. The proposed models were also compared to logistic regression modeling of mammographic breast density. Area under the receiver operating characteristic curve (AUC) was used as the model performance metric. Results: The highest AUC was 0.73 [95% Confidence Interval (CI): 0.68–0.78; GoogLeNet‐LDA model on CC view] when using the whole‐breast and was 0.72 (95% CI: 0.67–0.76; GoogLeNet‐LDA model on MLO + CC view) when using the dense tissue, respectively, as the model input. The GoogleNet‐LDA model significantly (all P < 0.05) outperformed the end‐to‐end GoogLeNet model in all experiments. CC view was consistently more predictive than MLO view in both deep learning models, regardless of the input subregions. Both models exhibited superior performance than the percent breast density (AUC = 0.54; 95% CI: 0.49–0.59). Conclusions: The proposed deep learning modeling approach can predict short‐term breast cancer risk using normal screening mammogram images. Larger studies are needed to further reveal the promise of deep learning in enhancing imaging‐based breast cancer risk assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13886

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 128

Metadata

Authors
Arefan, D., Mohamed, A. A., Berg, W. A., Zuley, M. L., Sumkin, J. H., & Wu, S.
Venue
Medical Physics
Publisher
Wiley
Published
2019-11-19
Volume
47
Issue
1
Pages
110-118
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2986544402
Cited by
128
References
12
FWCI
5.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.