Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Background: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro‐ and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. Aims: To respond to these needs, we developed G4‐Med, a benchmarking and regression testing system of Geant4 for medical physics. Materials and Methods: G4‐Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4‐Med are executed on the CERN computing infrastructure via the use of the geant‐val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. Results: This paper describes the tests included in G4‐Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. Discussion: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. Conclusion: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Self-citationGeant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Self-citationAllison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
Self-citationTOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationPerry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., & von Karsa, L. (2008) · Annals of Oncology · doi:10.1093/annonc/mdm481 · Cited by 1,020
Baró, J., Sempau, J., Fernández-Varea, J. M., & Salvat, F. (1995) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(95)00349-5 · Cited by 799
Jan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Self-citationINCERTI, S., BALDACCHINO, G., BERNAL, M., CAPRA, R., CHAMPION, C., FRANCIS, Z., GUÈYE, P., MANTERO, A., MASCIALINO, B., MORETTO, P., et al. (2010) · International Journal of Modeling, Simulation, and Scientific Computing · doi:10.1142/s1793962310000122 · Cited by 538
Self-citationBernal, M. A., Bordage, M. C., Brown, J. M. C., Davídková, M., Delage, E., El Bitar, Z., Enger, S. A., Francis, Z., Guatelli, S., Ivanchenko, V. N., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.10.087 · Cited by 536
Self-citationComparison of GEANT4 very low energy cross section models with experimental data in water
Incerti, S., Ivanchenko, A., Karamitros, M., Mantero, A., Moretto, P., Tran, H. N., Mascialino, B., Champion, C., Ivanchenko, V. N., Bernal, M. A., et al. (2010) · Medical Physics · doi:10.1118/1.3476457 · Cited by 514
Self-citationBoudard, A., Cugnon, J., David, J.-C., Leray, S., & Mancusi, D. (2013) · Physical Review C · doi:10.1103/physrevc.87.014606 · Cited by 514
Incerti, S., Kyriakou, I., Bernal, M. A., Bordage, M. C., Francis, Z., Guatelli, S., Ivanchenko, V., Karamitros, M., Lampe, N., Lee, S. B., et al. (2018) · Medical Physics · doi:10.1002/mp.13048 · Cited by 439
Self-citationElsässer, T., Weyrather, W. K., Friedrich, T., Durante, M., Iancu, G., Krämer, M., Kragl, G., Brons, S., Winter, M., Weber, K.-J., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.014 · Cited by 351
The Binary Cascade: Nucleon nuclear reactions
Folger, G., Ivanchenko, V. N., & Wellisch, J. P. (2004) · The European Physical Journal A · doi:10.1140/epja/i2003-10219-7 · Cited by 272
Self-citationThe experimental nuclear reaction data (EXFOR): Extended computer database and Web retrieval system
Zerkin, V. V., & Pritychenko, B. (2018) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2018.01.045 · Cited by 269
Tommasino, F., & Durante, M. (2015) · Cancers · doi:10.3390/cancers7010353 · Cited by 252
Paganetti, H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/5/305 · Cited by 237
Chaudhary, P., Marshall, T. I., Perozziello, F. M., Manti, L., Currell, F. J., Hanton, F., McMahon, S. J., Kavanagh, J. N., Cirrone, G. A. P., Romano, F., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.010 · Cited by 229
Self-citationFriedrich, T., Scholz, U., Elsässer, T., Durante, M., & Scholz, M. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2011.611213 · Cited by 205
Comparison of Geant4 electromagnetic physics models against the NIST reference data
Amako, K., Guatelli, S., Ivanchenko, V. N., Maire, M., Mascialino, B., Murakami, K., Nieminen, P., Pandola, L., Parlati, S., Pia, M. G., et al. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.852691 · Cited by 191
Self-citationGeometry and physics of the Geant4 toolkit for high and medium energy applications
Apostolakis, J., Asai, M., Bogdanov, A., Burkhardt, H., Cosmo, G., Elles, S., Folger, G., Grichine, V., Gumplinger, P., Heikkinen, A. M., et al. (2009) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2009.04.026 · Cited by 175
Self-citationExtension of the Liège intranuclear-cascade model to reactions induced by light nuclei
Mancusi, D., Boudard, A., Cugnon, J., David, J.-C., Kaitaniemi, P., & Leray, S. (2014) · Physical Review C · doi:10.1103/physrevc.90.054602 · Cited by 169
Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
Böhlen, T. T., Cerutti, F., Dosanjh, M., Ferrari, A., Gudowska, I., Mairani, A., & Quesada, J. M. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/19/014 · Cited by 162
Self-citationGeant4 low energy electromagnetic physics
Chauvie, S., Guatelli, S., Ivanchenko, V., Longo, F., MANTERO, A., MASCIALINO, B., Nieminen, P. J., Pandola, L., Parlati, S., Peralta, L., et al. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1462612 · Cited by 159
Self-citationArce, P., Ignacio Lagares, J., Harkness, L., Pérez-Astudillo, D., Cañadas, M., Rato, P., de Prado, M., Abreu, Y., de Lorenzo, G., Kolstein, M., et al. (2014) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2013.09.036 · Cited by 159
Self-citationValidation of the Geant4 electromagnetic photon cross-sections for elements and compounds
Cirrone, G. A. P., Cuttone, G., Rosa, F. D., Pandola, L., ROMANO, F., & Zhang, Q. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.02.112 · Cited by 140
Self-citationGeant4 models for simulation of multiple scattering
Ivanchenko, V., Kadri, O., Maire, M., & Urbán, L. (2010) · Journal of Physics Conference Series · doi:10.1088/1742-6596/219/3/032045 · Cited by 136
Self-citationCortés-Giraldo, M. A., & Cárabe, A. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/7/2645 · Cited by 128
Self-citationWright, D. H., & Kelsey, M. H. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.09.058 · Cited by 124
Self-citationICRU report 85: fundamental quantities and units for ionizing radiation
Thomas, D. J. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncs077 · Cited by 117
Electron‐specimen interactions in low‐voltage scanning electron microscopy
Böngeler, R., Golla‐Schindler, U., Kässens, M., Reimer, L., Schindler, B., Senkel, R., & Spranck, M. (1993) · Scanning · doi:10.1002/sca.4950150102 · Cited by 102
Microdosimetry of electrons in liquid water using the low-energy models of Geant4
Kyriakou, I., Emfietzoglou, D., Ivanchenko, V., Bordage, M., Guatelli, S., Lazarakis, P., Tran, H. N., & Incerti, S. (2017) · Journal of Applied Physics · doi:10.1063/1.4992076 · Cited by 99
Self-citationThe International Commission on Radiation Units and Measurements
Seltzer, S. M., Bartlett, D. T., Burns, D. T., Dietze, G., Menzel, H.-G., Paretzke, H. G., & Wambersie, A. (2011) · Journal of the ICRU · doi:10.1093/jicru/ndr011 · Cited by 98
Validation of recent Geant4 physics models for application in carbon ion therapy
Lechner, A., Ivanchenko, V., & Knobloch, J. (2010) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.04.008 · Cited by 87
Self-citationBenchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies
Faddegon, B., Asai, M., Perl, J., Ross, C. K., Sempau, J., Tinslay, J., & Salvat, F. (2008) · Medical Physics · doi:10.1118/1.2975150 · Cited by 83
Self-citationLindborg, L., Hultqvist, M., Tedgren, Å. C., & Nikjoo, H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/10/3089 · Cited by 80
Calculation of photon energy deposition kernels and electron dose point kernels in water
Mainegra‐Hing, E., Rogers, D. W. O., & Kawrakow, I. (2005) · Medical Physics · doi:10.1118/1.1861412 · Cited by 80
Lazarakis, P., Incerti, S., Ivanchenko, V., Kyriakou, I., Emfietzoglou, D., Corde, S., Rosenfeld, A. B., Lerch, M., Tehei, M., & Guatelli, S. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aaa6aa · Cited by 79
Self-citationErrata and Addenda for ICRU Report 73, Stopping of ions heavier than helium
Sigmund, P., Schinner, A., & Paul, H. (2009) · University of Southern Denmark Research Portal (University of Southern Denmark) · Cited by 75
Kyriakou, I., Ivanchenko, V., Sakata, D., Bordage, M., Guatelli, S., Incerti, S., & Emfietzoglou, D. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.01.001 · Cited by 71
Self-citationAn implementation of discrete electron transport models for gold in the Geant4 simulation toolkit
Sakata, D., Incerti, S., Bordage, M., Lampe, N., Okada, S., Emfietzoglou, D., Kyriakou, I., Murakami, K., Sasaki, T., Tran, H. N., et al. (2016) · Journal of Applied Physics · doi:10.1063/1.4972191 · Cited by 66
Self-citationNAPOLI, M. D., Agodi, C., Battistoni, G., Blancato, A. A., Cirrone, G. A. P., Cuttone, G., Giacoppo, F., Morone, M. C., Nicolosi, D., Pandola, L., et al. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7651 · Cited by 63
Self-citationToshito, T., Kodama, K., Sihver, L., Yusa, K., Ozaki, M., Amako, K., Kameoka, S., Murakami, K., Sasaki, T., Aoki, S., et al. (2007) · Physical Review C · doi:10.1103/physrevc.75.054606 · Cited by 57
Self-citationValidation of Geant4 fragmentation for Heavy Ion Therapy
Bolst, D., Cirrone, G. A. P., Cuttone, G., Folger, G., Incerti, S., Ivanchenko, V., Koi, T., Mancusi, D., Pandola, L., ROMANO, F., et al. (2017) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.06.046 · Cited by 53
Self-citationBichsel, H., Hiraoka, T., & Omata, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)153[0208:aofid]2.0.co;2 · Cited by 50
A low energy bound atomic electron Compton scattering model for Geant4
Brown, J. M. C., Dimmock, M., Gillam, J. E., & Paganin, D. M. (2014) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2014.07.042 · Cited by 48
Self-citationBACKSCATTERING COEFFICIENTS FOR LOW ENERGY ELECTRONS
Assa, A. M. D., & Gomati, M. M. E. (1998) · Cited by 40
Koi, T. (2010) · Institutional Repositories DataBase (IRDB) · Cited by 36
Measurement of multiple scattering of 13 and electrons by thin foils
Ross, C. K., McEwen, M. R., McDonald, A., Cojocaru, C. D., & Faddegon, B. (2008) · Medical Physics · doi:10.1118/1.2968095 · Cited by 35
Self-citationDesigning a range modulator wheel to spread-out the Bragg peak for a passive proton therapy facility
Jia, S. B., ROMANO, F., Cirrone, G. A. P., Cuttone, G., Hadizadeh, M. H., Mowlavi, A. A., & Raffaele, L. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.10.006 · Cited by 31
Self-citationCirrone, G. A. P., Cuttone, G., Raffaele, L., Salamone, V., Avitabile, T., Privitera, G., Spatola, C., Amico, A. G., Larosa, G., Leanza, R., et al. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00223 · Cited by 30
Self-citationRecent progress of Geant4 electromagnetic physics for calorimeter simulation
Incerti, S., Ivanchenko, V., & Novak, M. (2018) · Journal of Instrumentation · doi:10.1088/1748-0221/13/02/c02054 · Cited by 29
Self-citationAkagi, T., Aso, T., Go, I. W. A. I., Kimura, A., Kameoka, S., Lee, S. B., Maeda, Y., Matsufuji, N., Nishio, T., Omachi, C., et al. (2014) · Progress in Nuclear Science and Technology · doi:10.15669/pnst.4.896 · Cited by 29
Self-citationGeant4 electromagnetic physics: improving simulation performance and accuracy
Ivanchenko, V., Incerti, S., Allison, J., Bagulya, A., Brown, J. M. C., Champion, C., Elles, S., Francis, Z., Grichine, V., Ivanchenko, A., et al. (2014) · Joint International Conference on Supercomputing in Nuclear Applications + Monte Carlo (SNA + MC) · doi:10.1051/snamc/201403101 · Cited by 25
Self-citationA simple model for integral hadron–nucleus and nucleus–nucleus cross-sections
Grichine, V. (2009) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2009.05.020 · Cited by 24
Fedon, C., Caballo, M., & Sechopoulos, I. (2018) · Medical Physics · doi:10.1002/mp.13069 · Cited by 24
Self-citationCirrone, G. A. P., Cuttone, G., Raffaele, L., Salamone, V., Avitabile, T., Privitera, G., Spatola, C., Amico, A. G., Larosa, G., Leanza, R., et al. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00247 · Cited by 21
Self-citationElectron backscattering simulation in Geant4
Dondero, P., MANTERO, A., Ivanchenko, V., Lotti, S., Mineo, T., & Fioretti, V. (2018) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2018.03.037 · Cited by 20
Self-citationFedon, C., Caballo, M., Longo, R., Trianni, A., & Sechopoulos, I. (2018) · Medical Physics · doi:10.1002/mp.12792 · Cited by 19
Self-citationChiral-invariant phase space model
Kossov, M. (2002) · The European Physical Journal A · doi:10.1140/epja/i2001-10211-3 · Cited by 18
Petringa, G., ROMANO, F., Manti, L., Pandola, L., Attili, A., Cammarata, F. P., Cuttone, G., Forte, G. I., Manganaro, L., Pipek, J., et al. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.01.018 · Cited by 17
Self-citationGeant4 hadron elastic diffuse model
Grichine, V. (2010) · Computer Physics Communications · doi:10.1016/j.cpc.2010.01.004 · Cited by 12
Perrot, Y. (2011) · theses.fr (ABES) · doi:10.70675/e83075c0zf0f6z490fz950ezb375fddd861d · Cited by 11
Self-citationPreliminary results in using Deep Learning to emulate BLOB, a nuclear interaction model
Ciardiello, A., Asai, M., Caccia, B., Cirrone, G. A. P., Colonna, M., Dotti, A., Faccini, R., Giagu, S., Messina, A., Napolitani, P., et al. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.04.005 · Cited by 7
Self-citation
Metadata
- Authors
- Arce, P., Bolst, D., Bordage, M. ‐., Brown, J. M. C., Cirrone, P., Cortés‐Giraldo, M. A., Cutajar, D., Cuttone, G., Desorgher, L., Dondero, P., Dotti, A., Faddegon, B., Fedon, C., Guatelli, S., Incerti, S., Ivanchenko, V., Konstantinov, D., Kyriakou, I., Latyshev, G., Le, A., Mancini‐Terracciano, C., Maire, M., Mantero, A., Novak, M., Omachi, C., Pandola, L., Perales, A., Perrot, Y., Petringa, G., Quesada, J. M., Ramos‐Méndez, J., Romano, F., Rosenfeld, A. B., Sarmiento, L. G., Sakata, D., Sasaki, T., Sechopoulos, I., Simpson, E. C., Toshito, T., & Wright, D. H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2020-12-12
- Volume
- 48
- Issue
- 1
- Pages
- 19-56
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W3022257328
- Cited by
- 187
- References
- 64
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.