Spherical navigator echoes for full 3D rigid body motion measurement in MRI
Open accessAbstract
We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k‐space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k‐space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least‐squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k‐space sampling strategies on such a shell. Data collected with a computer‐controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time‐intensive sampling method. This number of samples can be captured in an approximately 27‐ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes. Magn Reson Med 47:32–41, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Tisdall, M. D., Hess, A. T., Reuter, M., Meintjes, E. M., Fischl, B., & van der Kouwe, A. J. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23228 · Cited by 443
Prospective motion correction in brain imaging: A review
Maclaren, J., Herbst, M., Speck, O., & Zaitsev, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24314 · Cited by 401
Zaitsev, M., Dold, C., Sakas, G., Hennig, J., & Speck, O. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.039 · Cited by 391
PROMO: Real‐time prospective motion correction in MRI using image‐based tracking
White, N., Roddey, C., Shankaranarayanan, A., Han, E., Rettmann, D., Santos, J., Kuperman, J., & Dale, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22176 · Cited by 376
A study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281
Alexander-Bloch, A., Clasen, L., Stockman, M., Ronan, L., Lalonde, F., Giedd, J., & Raznahan, A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23180 · Cited by 178
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
Alliance for aging research AD biomarkers work group: structural MRI
Jack, C. R. (2011) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2011.09.011 · Cited by 64
Self-citationCUDA accelerated method for motion correction in MR PROPELLER imaging
Feng, C., Yang, J., Zhao, D., & Liu, J. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.04.013 · Cited by 8
Metadata
- Authors
- Welch, E. B., Manduca, A., Grimm, R. C., Ward, H. A., & Jack Jr., C. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-12-20
- Volume
- 47
- Issue
- 1
- Pages
- 32-41
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2160928837
- Cited by
- 212
- References
- 0
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.