The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI
Open accessAbstract
We introduce a novel method of prospectively compensating for subject motion in neuroanatomical imaging. Short three‐dimensional echo‐planar imaging volumetric navigators are embedded in a long three‐dimensional sequence, and the resulting image volumes are registered to provide an estimate of the subject's location in the scanner at a cost of less than 500 ms, ∼ 1% change in contrast, and ∼3% change in intensity. This time fits well into the existing gaps in sequences routinely used for neuroimaging, thus giving a motion‐corrected sequence with no extra time required. We also demonstrate motion‐driven selective reacquisition of k‐space to further compensate for subject motion. We perform multiple validation experiments to evaluate accuracy, navigator impact on tissue intensity/contrast, and the improvement in final output. The complete system operates without adding additional hardware to the scanner and requires no external calibration, making it suitable for high‐throughput environments. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Self-citationHan, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Self-citationGeneralized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776
Cited by
Within-subject template estimation for unbiased longitudinal image analysis
Reuter, M., Schmansky, N. J., Rosas, H. D., & Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.084 · Cited by 2,356
Self-citationSpurious group differences due to head motion in a diffusion MRI study
Yendiki, A., Koldewyn, K., Kakunoori, S., Kanwisher, N., & Fischl, B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.027 · Cited by 508
Self-citationHead motion during MRI acquisition reduces gray matter volume and thickness estimates
Reuter, M., Tisdall, M. D., Qureshi, A., Buckner, R. L., van der Kouwe, A. J. W., & Fischl, B. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.006 · Cited by 457
Self-citationJoshi, S. H., Espinoza, R. T., Pirnia, T., Shi, J., Wang, Y., Ayers, B., Leaver, A., Woods, R. P., & Narr, K. L. (2016) · Biological Psychiatry · doi:10.1016/j.biopsych.2015.02.029 · Cited by 320
Neuroanatomical Correlates of the Income-Achievement Gap
Mackey, A. P., Finn, A. S., Leonard, J. A., Jacoby-Senghor, D. S., West, M. R., Gabrieli, C. F. O., & Gabrieli, J. D. E. (2015) · Psychological Science · doi:10.1177/0956797615572233 · Cited by 176
Metadata
- Authors
- Tisdall, M. D., Hess, A. T., Reuter, M., Meintjes, E. M., Fischl, B., & van der Kouwe, A. J. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-12-28
- Volume
- 68
- Issue
- 2
- Pages
- 389-399
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1989364786
- Cited by
- 443
- References
- 4
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI. https://app.cochat.ai/papers/10.1002/mrm.23228
- The paper
- Tisdall, M. D., Hess, A. T., Reuter, M., Meintjes, E. M., Fischl, B., & van der Kouwe, A. J. W. (2012). Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.23228
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.