Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI

Menon, Ravi S.·2002·Magnetic Resonance in Medicine

Abstract

Large‐vessel BOLD contamination is a serious impediment to localization of neural activity in high‐resolution fMRI studies. A new method is presented which estimates and removes the fraction of BOLD signal that arises from oriented vessels, such as cerebral and pial veins in a voxel, by measuring their influence on the phase angle of the complex valued fMRI time series. A maximum likelihood estimator based on a linear least‐squares fit of the BOLD signal phase to the BOLD signal magnitude in a voxel is shown to efficiently suppress the BOLD effect from these larger veins, whose activation is not well colocalized with the neural response. In high‐resolution in vivo fMRI data at 4 T, it is estimated that the method is sensitive to the phase changes in the cerebral, larger intracortical, and pial veins. The technique requires no special pulse sequence modifications or acquisition strategies, and is computationally fast and intrinsically robust. Magn Reson Med 47:1–9, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10041

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 214

Metadata

Authors
Menon, R. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-12-20
Volume
47
Issue
1
Pages
1-9
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2025836502
Cited by
214
References
1
FWCI
3.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.