Limitations and requirements of diffusion tensor fiber tracking: an assessment using simulations
Open accessAbstract
Diffusion tensor fiber tracking potentially can give information about in vivo brain connectivity. However, this technique is difficult to validate due to the lack of a gold standard. Fiber tracking reliability will depend on the quality of the data and on the robustness of the algorithms used. Information about the effects of various anatomical and image acquisition parameters on fiber tracking reliability may be used in the design of imaging sequences and of tracking algorithms. In this study, tracking was performed on two different simulated models to study the effects on tracking quality of SNR, anisotropy, curvature, fiber cross‐section, background anisotropy, step size, and interpolation. Tracking was also performed on volunteer data to assess the relevance of the simulations to real data. Our results show that, in general, tracking with high SNR and high anisotropy using interpolation and a low step size gives the most reliable results. Partial volume effects are shown to have a detrimental effect when the background is anisotropic and when tracking narrow fibers. The results derived from real data show similar trends and thus support the findings of the simulations. These simulations may therefore help to determine which structures can be tracked for a given image quality. Magn Reson Med 47:701–708, 2002. © 2002 Wiley‐Liss, Inc.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
First-order streamline tractography in curved bundles tends to underestimate curvature, producing erroneous trajectories.
“Possibly the earliest bias established for dMRI tractography was the fact that if the streamline algorithm simply takes a step of finite size in the direction of the local fiber orientation at the current vertex (a so-called “first-order” method), streamlines in curved bundles will tend to under-estimate the curvature, resulting in erroneous trajectories (Tournier et al., 2002).”
From Quantitative mapping of the brain’s structural connectivity using diffusion MRI tractography: A review (2022) · cites this paper as Tournier et al., 2002
The Tracking Algorithm section describes finite steps taken in the local major-eigenvector direction. Model A reports that larger steps increase endpoint offset and that tracks can depart systematically from an ideal curved path, especially without interpolation. The copy does not establish the claimed direction of the bias—that these tracks tend to underestimate curvature. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- Basser PJ, Mattiello J, LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys J 1994;66:259 -267.
- Lin C-P, Tseng W-YI, Chen J-H. Validation of diffusion tensor magnetic resonance axonal fiber imaging. In: Proceedings of the 17th Annual Meeting of ESMRMB, Paris, France, 2000. p. 106.
- Holmes AA, Scollan DF, Winslow RL. Direct histological validation of diffusion tensor MRI in formaldehyde-fixed myocardium. Magn Reson Med 2000;44:157-161.
- Xue R, van Zijl PCM, Crain BJ, Solaiyappan M, Mori S. In vivo three- dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging. Magn Reson Med 1999;42:1123-1127.
- Mori S, Crain BJ, Chacko VP, van Zijl PCM. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann Neurol 1999;45:265-269.
- Conturo TE, Lori NF, Cull TS, Akbudak E, Snyder AZ, Shimony JS, McKinstry RC, Burton H, Raichle ME. Tracking neuronal fiber path- ways in the living human brain. Proc Natl Acad Sci USA 1999;96: 10422-10427.
- Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography using DT-MRI data. Magn Reson Med 2000;44:625-632.
- Lori NF, Akbudak E, Snyder AZ, Shimony JS, Conturo TE. Diffusion tensor tracking of human neuronal fiber bundles: simulation of effects of noise, voxel size and data interpolation. In: Proceedings of the 8th Annual Meeting of ISMRM, Denver, 2000. p 775.
- Basser PJ, Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B 1996;111:209 -219.
- Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 1995;34:910 -914.
- Henkelman RM. Measurement of signal intensity in the presence of noise in MR images [published erratum in Med Phys 1986;13:544]. Med Phys 1985;12:232-233.
- Basser PJ. Inferring microstructural features and the physiological state of tissues from diffusion-weighted images. NMR Biomed 1995;8:333- 344.
- Calamante F, Porter DA, Gadian DG, Connelly A. Correction for eddy current induced B 0 shifts in diffusion-weighted echo-planar imaging. Magn Reson Med 1999;41:95-102.
- Poupon C, Clarck CA, Frouin V, Regis J, Bloch I, Le Bihan D, Mangin J-F. Regularization of diffusion-based direction maps for the tracking of brain white matter fascicles. NeuroImage 2000;12:184 -195.
Cited by
Sorted by citations
MRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370 · see citing works
“Systematic ‘‘overshoot’’ errors have been shown to occur when tracking curved structures, particularly when large step sizes are used (Tournier et al., 2002).”
BackgroundSelf-citationDiffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers
Wedeen, V. J., Wang, R., Schmahmann, J. D., Benner, T., Tseng, W. I., Dai, G., Pandya, D. Ν., Hagmann, P., D'Arceuil, H. E., & de Crespigny, A. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.036 · Cited by 941 · see citing works
“MRI tractography as initiated within the framework of diffusion tensor imaging (DTI) (Conturo et al., 1999; Mori et al., 1999; Wedeen et al., 1995), falls short of this goal (Basser et al., 2000; Lazar and Alexander, 2003; Tournier et al., 2002).”
BackgroundDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921 · see citing works
“Noise in the DW measurements will inevitably introduce uncertainty in the estimated fiber orientations, which may in turn introduce errors in the delineated pathway (153,154,157,172).”
Self-citationDiffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 574 · see citing works
Beyond the arcuate fasciculus: consensus and controversy in the connectional anatomy of language
Dick, A. S., & Tremblay, P. (2012) · Brain · doi:10.1093/brain/aws222 · Cited by 470 · see citing works
“Despite the major advances in understanding fibre pathways in the human brain, DTI tractography suffers from several serious shortcomings that are often minimized (Tournier et al., 2002; Assaf and Pasternak, 2008).”
BackgroundTheoretical analysis of the effects of noise on diffusion tensor imaging
Anderson, A. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1315 · Cited by 278 · see citing works
“[18] and [24]), and hence the eigenvalue bias by the factor 1/N (see Appendix D).”
BackgroundZhang, F., Daducci, A., He, Y., Schiavi, S., Seguin, C., Smith, R. E., Yeh, C.-H., Zhao, T., & O’Donnell, L. J. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118870 · Cited by 302 · see citing works
“sulting in erroneous trajectories [455].”
Functional anatomy of interhemispheric cortical connections in the human brain
Zarei, M., Johansen-Berg, H., Smith, S. M., Ciccarelli, O., Thompson, A. J., & Matthews, P. M. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00615.x · Cited by 230 · see citing works
“Limitations of the DTI and tractography used here were discussed previously (Tournier et al. 2002).”
MethodBootstrap white matter tractography (BOOT-TRAC)
Lazar, M., & Alexander, A. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.08.050 · Cited by 208 · see citing works
In vivo MR tractography using diffusion imaging
Bammer, R., Acar, B., & Moseley, M. E. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00311-x · Cited by 233 · see citing works
An error analysis of white matter tractography methods: synthetic diffusion tensor field simulations
Lazar, M., & Alexander, A. L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00277-5 · Cited by 169 · see citing works
Campbell, J. S. W., Siddiqi, K., Rymar, V. V., Sadikot, A. F., & Pike, G. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.014 · Cited by 177 · see citing works
“While simulated data can provide a gold standard to which tracking results can be compared (Lazar and Alexander, 2003; Lori et al., 2002; Tournier et al., 2002), it is of additional value to evaluate the results of tracking on real MRI data in the presence of normal imaging artifacts, noise characteristics, and voxel…”
BackgroundMethodFiberfox: Facilitating the creation of realistic white matter software phantoms
Neher, P., Laun, F. B., Stieltjes, B., & Maier-Hein, K. H. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25045 · Cited by 112 · see citing works
Mapping brain anatomical connectivity using white matter tractography
Lazar, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1579 · Cited by 128 · see citing works
“Abbreviations used: DKI, diffusional kurtosis imaging; DKI-ODF, diffusional kurtosis imaging ODF; DSI, diffusion spectrum imaging; DT, diffusion tensor; DTI, diffusion tensor imaging; FACT, fiber assignment by continuous tracking; FOD, fiber orientation distribution; HARDI, high angular resolution diffusion imaging; i…”
BackgroundInfluentialFrey, D., Strack, V., Wiener, E., Jussen, D., Vajkoczy, P., & Picht, T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.059 · Cited by 139 · see citing works
“Influence of volume effects, i.e. tumors, and background noise on fiber track reconstruction remains a challenge as well (Tournier et al., 2002; Lazar et al., 2003; Lazar and Alexander, 2005).”
BackgroundClose, T., Tournier, J., Calamante, F., Johnston, L. A., Mareels, I., & Connelly, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.077 · Cited by 82 · see citing works
“While error propagation in streamlines tracking of a coherent fibre bundle has been extensively studied (Lori et al., 2002; Tournier et al., 2002; Lazar and Alexander, 2003), it is still not clear what effects different confounding factors will have on a given tracking algorithm when combined in…”
BackgroundMethodInfluentialSelf-citationStämpfli, P., Reischauer, C., Jaermann, T., Valavanis, A., Kollias, S., & Boesiger, P. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.025 · Cited by 95 · see citing works
“Furthermore, the tensors (and consequently the reconstructed fiber trajectories) can be compromised by partial volume effects or noise (Lazar and Alexander, 2003, 2005; Tournier et al., 2002).”
BackgroundResolving fiber crossing using advanced fast marching tractography based on diffusion tensor imaging
Stämpfli, P., Jaermann, T., Crelier, G. R., Kollias, S., Valavanis, A., & Boesiger, P. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.027 · Cited by 98 · see citing works
Validation of High-Resolution Tractography Against<i>In Vivo</i>Tracing in the Macaque Visual Cortex
Azadbakht, H., Parkes, L. M., Haroon, H. A., Augath, M., Logothetis, N. K., de Crespigny, A., D'Arceuil, H. E., & Parker, G. J. M. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhu326 · Cited by 103 · see citing works
“One approach to validation is to use computer-generated software phantoms (Gossl et al. 2002; Tournier et al. 2002; Lazar and Alexander 2003; Alexander 2005; Leemans et al. 2005; Watanabe et al. 2006; Descoteaux et al. 2007; Iturria-Medina et al. 2007; Sakaie and Lowe 2007) or physical phantoms…”
Kleiser, R., Stämpfli, P., Valavanis, A., Boesiger, P., & Kollias, S. (2009) · Neuroradiology · doi:10.1007/s00234-009-0539-2 · Cited by 116 · see citing works
“Consequently, simple tracking algorithms, which incorporate only the main diffusion direction for determining the propagation pathway (or track), are not adequate in such anatomically complex areas, and the reconstructed trajectories are often compromised by the wrong directional information [4, 17, 18, 21, 22, 42 , 4…”
BackgroundMathematical Methods for Diffusion MRI Processing
Lenglet, C., Campbell, J., Descoteaux, M., Haro, G., Savadjiev, P., Wassermann, D., Anwander, A., Deriche, R., Pike, G., Sapiro, G., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.054 · Cited by 100 · see citing works
“There has been considerable work on synthetic phantoms, e.g., (Lazar and Alexander, 2003; Tournier et al., 2002; Perrin et al., 2005; Close et al., 2008).”
White matter fiber tract segmentation in DT-MRI using geometric flows
Jonasson, L., Bresson, X., Hagmann, P., Cuisenaire, O., Meuli, R. A., & Thiran, J. (2004) · Medical Image Analysis · doi:10.1016/j.media.2004.07.004 · Cited by 82 · see citing works
“We have used a SNR of 8, 16 and 32 on the MR amplitude images as in (Tournier et al., 2002).”
BackgroundMethodQ-ball of inferior fronto-occipital fasciculus and beyond.
Caverzasi, E., Papinutto, N., Amirbekian, B., Berger, M. S., & Henry, R. G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0100274 · Cited by 97 · see citing works
“These shortcomings arise mainly because of partial volume effects [19] in voxels prone to tissues boundaries and regions where there are crossing or kissing fibers [20,21].”
BackgroundA level set method for segmentation of the thalamus and its nuclei in DT-MRI
Jonasson, L., Hagmann, P., Pollo, C., Bresson, X., Wilson, C. R., Meuli, R. A., & Thiran, J. (2006) · Signal Processing · doi:10.1016/j.sigpro.2005.12.017 · Cited by 73 · see citing works
“These tensors were then placed in six regions in a 3D volume and Rician noise was added [30].”
Methodvan der Jagt, P. K. N., Dik, P., Froeling, M., Kwee, T. C., Nievelstein, R. A. J., ten Haken, B., & Leemans, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.001 · Cited by 74 · see citing works
“Fiber tracking reliability also depends on the quality of the data and on the robustness of the algorithms used (Jeurissen et al., 2011; Tournier et al., 2002).”
Mathematical framework for simulating diffusion tensor MR neural fiber bundles
Leemans, A., Sijbers, J., Verhoye, M., der Linden, A. V., & Dyck, D. V. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20418 · Cited by 79 · see citing works
Tracking the mechanisms of deep brain stimulation for neuropsychiatric disorders
Luján, J. L. (2008) · Frontiers in bioscience · doi:10.2741/3124 · Cited by 69 · see citing works
Diffusion-weighted magnetic resonance imaging fibre tracking using a front evolution algorithm
Tournier, J., Calamante, F., Gadian, D. G., & Connelly, A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00236-2 · Cited by 73 · see citing works
Self-citationBiomimetic phantom for the validation of diffusion magnetic resonance imaging
Cristinacce, P. L. H., Zhou, F., Eichhorn, S. J., & Parker, G. J. M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25107 · Cited by 62 · see citing works
Degree of corticospinal tract damage correlates with motor function after stroke
Maraka, S., Jiang, Q., Jafari‐Khouzani, K., Li, L., Malik, S., Hamidian, H., Zhang, T., Lü, M., Hamid Soltanian-zadeh, A., Chopp, M., et al. (2014) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.132 · Cited by 65 · see citing works
Reconstruction of the human visual system based on DTI fiber tracking
Stämpfli, P., Rienmüller, A., Reischauer, C., Valavanis, A., Boesiger, P., & Kollias, S. S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21098 · Cited by 62 · see citing works
Christidi, F., Karavasilis, E., Samiotis, K., Bisdas, S., & Papanikolaou, N. K. (2016) · European Journal of Radiology Open · doi:10.1016/j.ejro.2016.06.002 · Cited by 62 · see citing works
Jones, R. J., Grisot, G., Augustinack, J. C., Magnain, C. V., Boas, D. A., Fischl, B. R., Wang, H., & Yendiki, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116704 · Cited by 56 · see citing works
“As it reconstructs only a single direction of diffusion in each voxel, it is inaccurate in areas where multiple fiber populations are present (Basser et al., 2000; Tournier et al., 2002).”
BackgroundTrack-weighted imaging methods: extracting information from a streamlines tractogram
Calamante, F. (2017) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0608-1 · Cited by 55 · see citing works
Self-citationHansen, B., Flint, J. J., Heon-Lee, C., Fey, M., Vincent, F., King, M. A., Vestergaard‐Poulsen, P., & Blackband, S. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.04.052 · Cited by 45 · see citing works
“…have been made to validate the accuracy of DTT maps using physical phantoms (Lin et al., 2003; Perrin et al., 2005), software phantoms (Lori et al., 2002; Tournier et al., 2002) or biological samples of uniform construction (Van Doorn et al., 1996; Van Donkelaar et al., 1999; Lin et al., 2001).”
BackgroundSelf-citationFibertract segmentation in position orientation space from high angular resolution diffusion MRI
Hagmann, P., Jonasson, L., Deffieux, T., Meuli, R. A., Thiran, J., & Wedeen, V. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.043 · Cited by 44 · see citing works
“Available online on ScienceDirect (www.sciencedirect.com). understood to have some significant limitations (Basser et al., 2000; Lazar and Alexander, 2003; Tournier et al., 2002), chief among them is its inability to image fiber crossings (Mori and van Zijl, 2002; Wiegell et al., 2000).”
BackgroundCristinacce, P. L. H., & Parker, G. J. M. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374709-9.00016-x · Cited by 35 · see citing works
Imaging of brain tumors with diffusion-weighted and diffusion tensor MR imaging.
Barboriak, D. (2003) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(03)00065-5 · Cited by 47
Mori, S., Kageyama, Y., Hou, Z., Aggarwal, M., Patel, J., Brown, T., Miller, M. I., Wu, D., & Troncoso, J. C. (2017) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2017.00016 · Cited by 48 · see citing works
“To retrieve intra-voxel anatomical information, many advanced diffusion-based analyses have been postulated, which do not resort to tensor-based contraction of observations into six parameters per voxel (e.g., Frank, 2001; Tournier et al., 2002, 2004; Tuch et al., 2003).”
MethodFan, Q., Nummenmaa, A. R., Wichtmann, B. D., Witzel, T., Mekkaoui, C., Schneider, W., Wald, L. L., & Huang, S. Y. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.004 · Cited by 48 · see citing works
“Several approaches have been taken to validate the metrics obtained from a variety of diffusion MRI methods ranging from fiber tractography to compartment size mapping, including the use of software phantoms (Balls and Frank, 2009; Close et al., 2009; Hall and Alexander, 2009; Leemans et al., 2005; Tournier et al., 20…”
Estimating the Confidence Level of White Matter Connections Obtained with MRI Tractography
Gigandet, X., Hagmann, P., Kurant, M., Cammoun, L., Meuli, R. A., & Thiran, J. (2008) · PLoS ONE · doi:10.1371/journal.pone.0004006 · Cited by 29 · see citing works
“[7].”
Kabasawa, H., Masutani, Y., Aoki, S., Abe, O., Masumoto, T., Hayashi, N., & Ohtomo, K. (2007) · Radiation Medicine · doi:10.1007/s11604-007-0169-8 · Cited by 38
Uncertainty in diffusion tensor based fibre tracking
Hahn, H. K., Klein, J., Nimsky, C., Rexilius, J., & Peitgen, H. O. (2007) · Springer eBooks · doi:10.1007/978-3-211-33303-7_6 · Cited by 24 · see citing works
“who showed that the accuracy of FT sensitively depends on the step size (27).”
BackgroundMethodProvenzale, J., Isaacson, J., & Chen, S. D. (2012) · AJR. American journal of roentgenology · doi:10.2214/ajr.11.7849 · Cited by 32
Generative Data Models for Validation and Evaluation of Visualization Techniques
Schulz, C., Nocaj, A., El‐Assady, M., Frey, S., Hlawatsch, M., Hund, M., Karch, G. K., Netzel, R., Schätzle, C., Butt, M., et al. (2016) · Workshop on Beyond Time and Errors: Novel Evaluation Methods for Visualization · doi:10.1145/2993901.2993907 · Cited by 28 · see citing works
“Synthetic datasets are used to test tensor fiber tracking [67, 112].”
MethodMR tractography with diffusion tensor imaging in clinical routine
Nguyen, T. H., Yoshida, M., Stievenart, J. L., Iba-Zizen, M. T., Bellinger, L., Abanou, A., Kitahara, K., & Cabanis, E. A. (2005) · Neuroradiology · doi:10.1007/s00234-005-1338-z · Cited by 25 · see citing works
“The acquisition time was shortened to a 5 min duration, including eight iterated acquisitions for a good signal to noise ratio [13, 21].”
MethodPhysical and digital phantoms for validating tractography and assessing artifacts
Drobnjak, I., Neher, P., Poupon, C., & Sarwar, T. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118704 · Cited by 18 · see citing works
Hu, B., Ye, B., Yang, Y., Zhu, K., Kang, Z., Kuang, S., Luo, L., & Shan, H. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.11.021 · Cited by 21 · see citing works
Unified framework for anisotropic interpolation and smoothing of diffusion tensor images
Mishra, A., Lu, Y., Meng, J., Anderson, A., & Ding, Z. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.031 · Cited by 28
“To date, a few well-established methods from the repository of classical image interpolation techniques have been empirically chosen for this purpose, such as linear (Tournier et al., 2002), low order polynomial (Xu et al.”
Segmentation of fiber tracts based on an accuracy analysis on diffusion tensor software phantoms
Barbieri, S., Bauer, M., Klein, J., Nimsky, C., & Hahn, H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.069 · Cited by 27
“Compared to the related work of Tournier et al. (2002) in which the deviation of single fibers from the ideal pathway is analyzed, the safety radius is a global measure of the tracked fiber bundle which gives us an indication of how close the tracked fiber bundle approaches the true border of the modeled pathway.”
Tracking and validation techniques for topographically organized tractography
Aydogan, D. B., & Shi, Y. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.071 · Cited by 28 · see citing works
Haakma, W., Dik, P., ten Haken, B., Froeling, M., Nievelstein, R. A. J., Cuppen, I., de Jong, T. P. V. M., & Leemans, A. (2014) · The Journal of Urology · doi:10.1016/j.juro.2014.02.2581 · Cited by 26 · see citing works
Schumacher, L. V., Reisert, M., Nitschke, K., Egger, K. E., Urbach, H., Hennig, J., Weiller, C., & Kaller, C. P. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.086 · Cited by 25 · see citing works
Diffusion tensor tractography of normal facial and vestibulocochlear nerves
Yoshino, M., Kin, T., Ito, A., Saito, T., Nakagawa, D., Kamada, K., Mori, H., Kunimatsu, A., Nakatomi, H., Oyama, H., et al. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-014-1129-2 · Cited by 24
Infants with perinatal hypoxic ischemia: feasibility of fiber tracking at birth and 3 months.
van Pul, C., Buijs, J., Vilanova, A., Roos, F. G., & Wijn, P. (2006) · Radiology · doi:10.1148/radiol.2393041523 · Cited by 23
“Tournier et al, by using simulations on synthetic data, showed that to identify small fibers, the signal-to-noise ratio needs to be high (40).”
MethodFaust, K., & Vajkoczy, P. (2016) · Journal of Neurosurgery · doi:10.3171/2015.3.jns141584 · Cited by 22
White Matter Mapping in DT-MRI Using Geometric Flows
Jonasson, L., Hagmann, P., Bresson, X., Meuli, R. A., Cuisenaire, O., & Thiran, J. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-45210-2_53 · Cited by 15 · see citing works
“To make the tensor fields more realistic, noise is added [24].”
BackgroundJacqmot, O., Thielen, B. V., Michotte, A., Willekens, I., Verhelle, F., Goossens, P., Ridder, F. D., Clarys, J. P., Vanbinst, A., Peleman, C., et al. (2017) · The Anatomical Record · doi:10.1002/ar.23579 · Cited by 15 · see citing works
Snow, N. J., Peters, S., Borich, M. R., Shirzad, N., Auriat, A. M., Hayward, K. S., & Boyd, L. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.09.025 · Cited by 14 · see citing works
Yeh, P., Oakes, T. R., & Riedy, G. P. (2012) · Open Journal of Medical Imaging · doi:10.4236/ojmi.2012.24025 · Cited by 13 · see citing works
“Linear interpolation via local path integration along principal diffusion directions, which is dubbed as fiber assignment by continuous tracking (FACT) [103] using the multiple region-of-interest “virtual dissection” [104], still remains the most popular approach of DTI tractography for clinical application [103, 105].”
MethodInfluence of User-Defined Parameters on Diffusion Tensor Tractography of the Corticospinal Tract
Parizel, P. M., Rompaey, V. V., Loock, R. V., Hecke, W. V., Goethem, J. W. V., Leemans, A., & Sijbers, J. (2007) · The Neuroradiology Journal · doi:10.1177/197140090702000202 · Cited by 15 · see citing works
White matter imaging in holoprosencephaly in children
Kinsman, S. L. (2004) · Current Opinion in Neurology · doi:10.1097/00019052-200404000-00006 · Cited by 18 · see citing works
D-BRAIN: Anatomically Accurate Simulated Diffusion MRI Brain Data
Perrone, D., Jeurissen, B., Aelterman, J., Roine, T., Sijbers, J., Pižurica, A., Leemans, A., & Philips, W. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149778 · Cited by 11 · see citing works
“[55] introduced phantoms based on apparent diffusion coefficient (ADC) and fractional anisotropy (FA), while Leemans et al.”
BackgroundWang, Y., Zhang, X.-P., Li, Y.-L., Li, X.-T., Hu, Y., Cui, Y., Sun, Y.-S., & Zhang, X.-Y. (2014) · Clinical Breast Cancer · doi:10.1016/j.clbc.2013.09.002 · Cited by 14
“In particular, this technique can be used to infer the directionality of white matter fiber architecture within a voxel.(1,2) With the further development of MRI technology, diffusion tensor imaging (DTI) can be used for the organs in the body.”
MethodLi, M., Ratnanather, J. T., Miller, M. I., & Mori, S. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.011 · Cited by 13 · see citing works
“…repeated under different conditions, leading to multiple potential paths from one seed voxel (Behrens et al., 2003; Jeurissen et al., 2011; Jones, 2003; Jones and Pierpaoli, 2005; Lazar and Alexander, 2003, 2005; Lori et al., 2002; Parker et al., 2002; Richter et al., 2013; Tournier et al., 2002).”
BackgroundAn image-processing toolset for diffusion tensor tractography
Mishra, A., Lu, Y., Choe, A. S., Aldroubi, A., Gore, J. C., Anderson, A. W., & Ding, Z. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.006 · Cited by 9 · see citing works
“However, only a few conventional interpolation techniques have been chosen for DTI data, such as linear [32], low-order polynomial [33,34], cubic B-spline [11] and nearest-neighbor interpolations [35].”
MethodDiffusion MRI Fiber Tractography
Smith, R., Connelly, A., & Calamante, F. (2020) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-12-817057-1.00023-8 · Cited by 12 · see citing works
Self-citationTensor deflection (TEND) tractography with adaptive subvoxel stepping
Chou, M., Wu, M., Chen, C., Wang, C., Huang, T., Liu, Y., Juan, C., & Chung, H. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20652 · Cited by 11 · see citing works
Segmentation of diffusion weighted MRI using the level set framework
Jonasson, L. (2005) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-3315 · Cited by 9 · see citing works
“1 Synthetic Tensor Fields The method was tested on the synthetic images with different levels of SNR, using an SNR of 8, 16 and 32 on the MR amplitude images as in [96].”
InfluentialWang, C.-C., Holly, L., Oughourlian, T., Yao, J., Raymond, C., Salamon, N., & Ellingson, B. (2021) · Journal of clinical neuroscience · doi:10.1016/j.jocn.2021.01.011 · Cited by 10
Kim, J., Phi, J., Lee, J. Y., Kim, K. H., Park, S.-H., Choi, Y.-H., Cho, B., & Kim, S.-K. (2018) · Brain Tumor Research and Treatment · doi:10.14791/btrt.2018.6.e14 · Cited by 10
“First, DTI is dependent on operators which leads to difficult in interpretations and standardization [23].”
BackgroundRatnanather, J. T., Lal, R. M., An, M., Poynton, C. B., Li, M., Jiang, H., Oishi, K., Selemon, L. D., Mori, S., & Miller, M. I. (2013) · Brain Connectivity · doi:10.1089/brain.2013.0143 · Cited by 12 · see citing works
“…limitations such as inability to discriminate crossing fi-bers, low signal-to-noise ratio (SNR), and poor tracking in regions of low anisotropy (Jbabdi and Johansen-Berg, 2011; Lazar and Alexander, 2003; Le Bihan et al., 2006; Moldrich et al., 2010; Mukherjee et al., 2008; Tournier et al., 2002).”
BackgroundSearching for Novel Biomarkers Using High Resolution Diffusion Tensor Imaging
Yassa, M. A. (2011) · Journal of Alzheimer s Disease · doi:10.3233/jad-2011-0005 · Cited by 10 · see citing works
“Various sophisticated fiber-tracking techniques have now become commonplace tools in neuroimaging laboratories for mapping white matter connectivity [8–12].”
Diffusion Tensor Imaging of Cerebral White Matter*
Stoeter, P., Dellani, P. R., & Vučurević, G. (2008) · Clinical Neuroradiology · doi:10.1007/s00062-008-8019-3 · Cited by 3 · see citing works
“Only after refinement of the original data by oversampling techniques, approximation and interpolation [12], reliable and smoothly running trajectories could be achieved.”
MethodRatnarajah, N., Simmons, A., Davydov, O., & Hojjatoleslami, A. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.07.005 · Cited by 10 · see citing works
“Several studies (Lazar and Alexander, 2003b; Tournier et al., 2002) have investigated the effects of image noise, tensor anisotropy, step size, and tract geometry on the accuracy of deterministic tractography algorithms.”
BackgroundBayesian regularization of diffusion tensor images
Frandsen, J. R., Hobolth, A., Østergaard, L., Vestergaard‐Poulsen, P., & Jensen, E. B. V. (2006) · Biostatistics · doi:10.1093/biostatistics/kxm005 · Cited by 8 · see citing works
Complementary Detection of Multiple Electrical Sources in Tissue Using Acoustoelectric Effects.
Wang, Z., Challoo, R., Peng, H., Leung, C. S., & Witte, R. (2016) · Ultrasound in Medicine and Biology · doi:10.1016/j.ultrasmedbio.2016.05.013 · Cited by 7
Estéban, O., Caruyer, E., Daducci, A., Cuadra, M. B., Ledesma‐Carbayo, M. J., & Santos, A. (2016) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2016.00004 · Cited by 8 · see citing works
“Early digital phantoms started with simulation of simple geometries (Basser et al., 2000; G¨ossl et al., 2002; Tournier et al., 2002; Leemans et al., 2005) to evaluate the angular resolution as well.”
BackgroundDiffusion Tensor Magnetic Resonance Imaging in Autism
Travers, B. G., & Alexander, A. L. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6843-1_8 · Cited by 3 · see citing works
“Measurement noise also causes errors in the DTI eigenvector directions (Anderson 2001; Lori et al. 2002; Tournier et al. 2002; Lazar and Alexander 2003), though these errors are relatively small in homogeneous WM pathways.”
BackgroundNew insights into the neurobiology of language from functional brain imaging
Tremblay, P., Dick, A. S., & Small, S. L. (2011) · Springer eBooks · doi:10.1007/978-3-7091-0723-2_10 · Cited by 3 · see citing works
“Despite these advances in understanding fiber pathways in the human brain, DTI tractography has some serious shortcomings that are often minimized or ignored in the literature [5, 86].”
BackgroundMethodUğurlu, D., Fırat, Z., Türe, U., & Ünal, G. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.008 · Cited by 7 · see citing works
The role for diffusion tensor imaging in neuropsychiatry
Taber, K. H., & Hurley, R. A. (2003) · Current Opinion in Psychiatry · doi:10.1097/01.yco.0000069092.26384.ff · Cited by 3 · see citing works
Global brain connectivity analysis by diffusion MR tractography
Gigandet, X. (2009) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-4511 · Cited by 6 · see citing works
“In order to tackle this issue, higher angular resolution diffusion MRI methodologies have been designed, such as Q-ball [215] or spherical deconvolution [210].”
MethodAdvances in longitudinal MRI diagnostic tests
Hernández-García, L., & Buschkuehl, M. (2012) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530059.2012.686995 · Cited by 5 · see citing works
“partial volume effects jeopardize the results of fiber-tracking algorithms, and that regions of low FA can also lead the fiber-tracking process astray [120].”
BackgroundOn the Reliability of Quantitative Volumetric and Structural Neuroimaging
Klein, J., Laun, F. B., Erhard, P., Diehl, V., & Hahn, H. K. (2008) · Imaging Decisions MRI · doi:10.1111/j.1617-0830.2009.00128.x · Cited by 3 · see citing works
“[4, 5] describe fibers by simple 2D rings in tensor fields, whereas other authors [30, 45, 60] define fibers by cylindric tubes in 3D tensor fields.”
BackgroundA method for non-rigid registration of diffusion tensor magnetic resonance images
Duda, J., Rivera, M., Alexander, D., & Gee, J. (2003) · SPIE Medical Imaging · doi:10.1117/12.481155 · Cited by 5
Quantitative Analysis and Comparison of Diffusion Tensor Imaging Tractography Algorithms
Crettenand, S., Meredith, S., Hoptman, M., & Reilly, R. (2006) · doi:10.1049/cp:20060421 · Cited by 4
“This is in line with other results reported in the literature [23].”
ResultSharma, A., Cabeen, R. P., Harris, N. G., Wright, D. K., Tohka, J., Gröhn, O. H. J., Bennett, A., Alba, C., Bhagavatula, S., Garner, R., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00471 · Cited by 4 · see citing works
“However, conventional diffusion tensor models are constrained by their single-fiber orientation representation and struggle in areas of complex fiber structures, such as regions with crossing fibers (Homos et al., 2017; Tournier et al., 2002).”
The Efficiency of Diffusion Weighted MRI and MR Spectroscopy On Breast MR Imaging.
Altay, C., & Balcı, P. (2014) · Journal of Breast Health · doi:10.5152/tjbh.2014.2142 · Cited by 3
Neuronal Fiber--tracking via optimal mass transportation
Daducci, A., Marigonda, A., Orlandi, G., & Posenato, R. (2012) · Communications on Pure & Applied Analysis · doi:10.3934/cpaa.2012.11.2157 · Cited by 3 · see citing works
Uncertainty in the DTI Visualization Pipeline
Siddiqui, F., Höllt, T., & Vilanova, A. (2021) · Mathematics and visualization · doi:10.1007/978-3-030-56215-1_6 · Cited by 3 · see citing works
“The integration step, or step size, further affect the quality of these integration schemes [97].”
BackgroundChapter 20 – Validation of Tractography
Hubbard, P., & Parker, G. (2014) · doi:10.1016/b978-0-12-396460-1.00020-2 · Cited by 3
Dellani, P. R., Glaser, M. B., Tropine, A., Vučurević, G., Bauermann, T., Wille, P. R., Strecker, U., Stadie, A. T., Perneczky, A., & Stoeter, P. (2004) · Clinical Neuroradiology · doi:10.1007/s00062-004-5396-0 · Cited by 2 · see citing works
“Mit steileren Gradientenfeldern, wie sie in den neueren MR-Geräten zur Verfügung stehen, sind zwar Messungen bei höheren b-Werten möglich, um so die Anisotropie zu vergrößern, was jedoch wegen der gleichzeitigen Abnahme des S/N mit einem Verlust an Datenhomogenität erkauft wird und nach unseren Erfahrungen die Trackin…”
BackgroundJin, R., Cai, Y., Zhang, S., Yang, T., Feng, H., Jiang, H.-Y., Zhang, X., Hu, Y., & Liu, J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1191999
“Nevertheless, fiber tracking is time-consuming and its computational process is complicated and easily affected by noises and artifacts (Tournier et al., 2002; Lazar and Alexander, 2003).”
BackgroundShape deformation measures for white matter fibers
Güler, R. A., Ugurlu, D., Fırat, Z., Türe, U., & Unal, G. (2016) · Signal Processing and Communications Applications Conference · doi:10.1109/siu.2016.7495980
Study of the sources of errors in fiber tracking using diffusion tensor MRI
Tawfik, M. M., Youssef, A.-B. M., & Kadah, Y. (2008) · National Radio Science Conference · doi:10.1109/nrsc.2008.4542384
Kleiser, R., Nickel, J., Seitz, R., Trenkler, J., & Wurm, G. (2012) · doi:10.1007/978-94-007-1706-0_19
- Authors
- Tournier, J. ‐., Calamante, F., King, M. D., Gadian, D. G., & Connelly, A.
- Affiliations
- Great Ormond Street Hospital (GB)
- University College London (GB)
- Corresponding author
- Tournier, J.‐D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-03-28
- Volume
- 47
- Issue
- 4
- Pages
- 701-708
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2047050738
- Cited by
- 114
- References
- 0
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 4 · 2018: 5 · 2017: 5 · 2016: 7 · 2015: 4 · 2014: 7 · 2013: 7 · 2012: 9
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- Wellcome Trust
- Great Ormond Street Hospital for Children
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- signal-to-noise ratio, anisotropy, fiber curvature, partial volume effect, step size, interpolation, tracking algorithm, white matter connectivity, image acquisition parameters
- MeSH terms
- Algorithms, Brain, Computer Simulation, Diffusion, Humans, Magnetic Resonance Imaging, Anisotropy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review