CoChat

Simultaneous echo refocusing in EPI

Feinberg, David A., Reese, Timothy G., Wedeen, Van J. · 2002 · Magnetic Resonance in Medicine
Cited by 89

The DOI matches its Crossref record.

Abstract

A method to encode multiple two‐dimensional Fourier transform (2D FT) images within a single echo train is presented. This new method, simultaneous echo refocusing (SER), is a departure from prior echo planar image (EPI) sequences which use repeated single‐shot echo trains for multislice imaging. SER simultaneously acquires multiple slices in a single‐shot echo train utilizing a shared refocusing process. The SER technique acquires data faster than conventional multislice EPI since it uses fewer gradient switchings and fewer preparation pulses such as diffusion gradients. SER introduces a new capability to simultaneously record multiple spatially separated sources of physiologic information in subsecond image acquisitions, which enables several applications that are dependent on temporal coherence in MRI data including velocity vector field mapping and brain activation mapping. Magn Reson Med 48:1–5, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10227

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 89

Metadata

Authors
Feinberg, D. A., Reese, T. G., & Wedeen, V. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-06-27
Volume
48
Issue
1
Pages
1-5
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2076105895
Cited by
89
References
0
FWCI
0.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous echo refocusing in EPI. https://app.cochat.ai/papers/10.1002/mrm.10227
The paper
Feinberg, D. A., Reese, T. G., & Wedeen, V. J. (2002). Simultaneous echo refocusing in EPI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10227

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.