Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging

Open access

Abstract

Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0015710

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Description of the M-EPI pulse sequence compared with conventional EPI. Top) EPI pulse sequence generates a single image during each readout which is repeated by the number of slices to scan the whole brain. Bottom) Multiplexed-EPI (M-EPI) pulse sequence generates several images during a single echo train readout and thus requires fewer repeats to scan the whole brain. The multibanded (MB) RF excitation pulses are the sum of n frequency offset sinc-modulated pulses which excite slices at widely spaced positions to improve the separation of signal from the different receiver coils. (Slice Positions) show closely spaced SIR images (red, blue, green) and the excitation positions of the n sinc pulses of the first MB pulse. The MB pulse is repeated m times for SIR excitations and corresponding signals (red, blue, green) are separated (K-Spaces) into individual k-spaces according to their temporal order in the signal readout period. The MB signals (same color) are further separated into k-spaces using the differential coil sensitivity. 2D FT image reconstruction of each individual k-space data set gives m×n number of M-EPI images.
Figure 1 Description of the M-EPI pulse sequence compared with conventional EPI. Top) EPI pulse sequence generates a single image during each readout which is repeated by the number of slices to scan the whole brain. Bottom) Multiplexed-EPI (M-EPI) pulse sequence generates several images during a single echo train readout and thus requires fewer repeats to scan the whole brain. The multibanded (MB) RF excitation pulses are the sum of n frequency offset sinc-modulated pulses which excite slices at widely spaced positions to improve the separation of signal from the different receiver coils. (Slice Positions) show closely spaced SIR images (red, blue, green) and the excitation positions of the n sinc pulses of the first MB pulse. The MB pulse is repeated m times for SIR excitations and corresponding signals (red, blue, green) are separated (K-Spaces) into individual k-spaces according to their temporal order in the signal readout period. The MB signals (same color) are further separated into k-spaces using the differential coil sensitivity. 2D FT image reconstruction of each individual k-space data set gives m×n number of M-EPI images.CC BY · PubMed Central
Figure 2 Images at 3 Tesla, comparing 4 adjacent slices out of the total 60 slices at 2mm isotropic resolution covering the entire brain. Each row of images was obtained with a different pulse sequence and slice acceleration, producing 1, 4, 6 and 12 slices from the EPI echo train. The mxn parameters (SIR× MB) are shown.
Figure 2 Images at 3 Tesla, comparing 4 adjacent slices out of the total 60 slices at 2mm isotropic resolution covering the entire brain. Each row of images was obtained with a different pulse sequence and slice acceleration, producing 1, 4, 6 and 12 slices from the EPI echo train. The mxn parameters (SIR× MB) are shown.CC BY · PubMed Central
Figure 3 M-EPI images acquired at 7 Tesla. left) M-EPI with 1.5 mm isotropic resolution comparing 1, 4 and 6 images per echo train utilizing different multiplexing. middle) SE EPI has chemical shift artifact (arrows) that is normally removed with fat-saturation RF pulses or using different pulse lengths for the excitation and the refocusing pulse; the SE M-EPI images have inherent absence of the fat ghost artifact and require half as many refocusing pulses to substantially reduce SAR. right) By increasing parallel imaging from R-3 to R-4, the echo train shortened to overcome SIR lengthening to remove the artifact (arrow) with similar appearance to EPI with R-3 and similar echo train length.
Figure 3 M-EPI images acquired at 7 Tesla. left) M-EPI with 1.5 mm isotropic resolution comparing 1, 4 and 6 images per echo train utilizing different multiplexing. middle) SE EPI has chemical shift artifact (arrows) that is normally removed with fat-saturation RF pulses or using different pulse lengths for the excitation and the refocusing pulse; the SE M-EPI images have inherent absence of the fat ghost artifact and require half as many refocusing pulses to substantially reduce SAR. right) By increasing parallel imaging from R-3 to R-4, the echo train shortened to overcome SIR lengthening to remove the artifact (arrow) with similar appearance to EPI with R-3 and similar echo train length.CC BY · PubMed Central
Figure 4 Neuronal Fiber tracks generated using the M-EPI sequence. Two projections of the 3D diffusion spectrum image (DSI) reveal large scale neuronal connections in major white matter pathways. 3T Diffusion acquisition parameters: DSI using b-maximum of 4500 s/mm2 and 256 b-value encodings; Imaging parameters: SIR2 × MB2, 3 mm resolution, total acquisition time 8.5 min., TR/2000 ms and signal bandwidth 2604 Hz/pixel.
Figure 4 Neuronal Fiber tracks generated using the M-EPI sequence. Two projections of the 3D diffusion spectrum image (DSI) reveal large scale neuronal connections in major white matter pathways. 3T Diffusion acquisition parameters: DSI using b-maximum of 4500 s/mm2 and 256 b-value encodings; Imaging parameters: SIR2 × MB2, 3 mm resolution, total acquisition time 8.5 min., TR/2000 ms and signal bandwidth 2604 Hz/pixel.CC BY · PubMed Central
Figure 5 Five example RSNs (resting state networks) from the 3 different 10-minute resting FMRI acquisitions, from subject 2. The color overlays are z-statistic images, thresholded at Z = 4 in all cases. In this central axial slice (Z = +18 mm in MNI152 standard space) the RSNs shown cover visual areas, the default mode network and a sensori-motor network.
Figure 5 Five example RSNs (resting state networks) from the 3 different 10-minute resting FMRI acquisitions, from subject 2. The color overlays are z-statistic images, thresholded at Z = 4 in all cases. In this central axial slice (Z = +18 mm in MNI152 standard space) the RSNs shown cover visual areas, the default mode network and a sensori-motor network.CC BY · PubMed Central
Figure 6 Boxplots over all RSNs (excluding the artefactual ICA components) and over all 3 subjects, quantifying various image statistics. The top row in each sub-figure shows a separate boxplot for each of the three TRs, and the bottom row shows the ratio of the 0.8 s and 0.4 s values to the 2.5 s values, the ratio being calculated separately for each RSN (and each subject) before feeding into the boxplot. Fig. 6a shows the results from a 100-dimensional ICA decomposition across all 3 TRs (separately for each subject) and Fig. 6b shows the results from a 10-dimensional regression of previously published large-scale RSNs from a separate study. For each regression type (multiple or single) and for each RSN map, we have a ‘mixture-model-corrected’ Z-stat image (see Methods). The two main measures we take from that Z-stat image are the peak value and the sum of all Z-stat values over a threshold. For the voxel having the peak Z-stat, we also report the parameter estimate (‘PE’, or RSN amplitude, shown as a % signal change) and the size of the regression residuals. Finally we also show the ratio of these two measures, which contains similar information to the Z-stat (i.e., CNR), but without taking into account the temporal DOF.
Figure 6 Boxplots over all RSNs (excluding the artefactual ICA components) and over all 3 subjects, quantifying various image statistics. The top row in each sub-figure shows a separate boxplot for each of the three TRs, and the bottom row shows the ratio of the 0.8 s and 0.4 s values to the 2.5 s values, the ratio being calculated separately for each RSN (and each subject) before feeding into the boxplot. Fig. 6a shows the results from a 100-dimensional ICA decomposition across all 3 TRs (separately for each subject) and Fig. 6b shows the results from a 10-dimensional regression of previously published large-scale RSNs from a separate study. For each regression type (multiple or single) and for each RSN map, we have a ‘mixture-model-corrected’ Z-stat image (see Methods). The two main measures we take from that Z-stat image are the peak value and the sum of all Z-stat values over a threshold. For the voxel having the peak Z-stat, we also report the parameter estimate (‘PE’, or RSN amplitude, shown as a % signal change) and the size of the regression residuals. Finally we also show the ratio of these two measures, which contains similar information to the Z-stat (i.e., CNR), but without taking into account the temporal DOF.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Cited by

See all 1,296

Metadata

Authors
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
Affiliations
  • University of California, San Francisco (US)
  • University of Minnesota (US)
  • John Radcliffe Hospital (GB)
  • Advanced MRI Technologies (United States) (US)
  • Washington University in St. Louis (US)
Corresponding author
Feinberg, David A.
Venue
PLoS ONE
Published
2010-12-20
Volume
5
Issue
12
Pages
e15710
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2114809469
Cited by
1,296
References
57
Citations by year
2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
FWCI
44.96
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
  • W. M. Keck Foundation
  • National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
  • National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
  • National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
  • National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
  • NIH Blueprint for Neuroscience Research (1U54-MH-091657)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
Keywords
echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
MeSH terms
Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging. https://app.cochat.ai/papers/10.1371/journal.pone.0015710
The paper
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010). Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging. PLoS ONE. https://doi.org/10.1371/journal.pone.0015710

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.