Human erythrocyte ghosts: Exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonance
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A tissue model composed of erythrocyte ghosts was developed to study the effects of compartmentation on the MR signal acquired from biological tissues. This simple and flexible model offers control over the biophysical parameters that contribute to multicomponent signals arising from cellular systems. Cell density, size, intra‐ and extracellular composition, and membrane permeability can be independently altered. The effects of cell density and cell size on water diffusion properties were assessed. The data demonstrate non‐monoexponential water diffusion in ghost cell suspensions of 17–67% cell density. Data were analysed with the widely employed two‐compartment (biexponential) model, and with a two‐compartment model that accounted for exchange between compartments. Water exchange between the intra‐ and extracellular compartments appeared to be significant over the range of diffusion times studied (7–35 ms). The biexponential fit to the ghost data appeared to be underparameterised as the ADCs and relative fractions of the fast and slow components were dependent on the experimental acquisition parameters, specifically the diffusion time. However, both analysis methods proved effective at tracking changes in the ghost model when it was perturbed. This was demonstrated with cell density variation, cell swelling and shrinkage experiments, and reduction of membrane water permeability using a water channel blocker (pCMBS). We anticipate that this model system could be used to investigate compartmental diffusion effects to simulate a range of pathologies, especially ischemic stroke. Magn Reson Med 48:649–657, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570 · cited 5×
“These parameters were chosen because cell swelling is attributed to be the primary cause of contrast in diffusion-weighted imaging (DWI) detection of stroke infarcts (3).”
BackgroundMethodInfluentialAn analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 2×
“Simulations by other groups imply that more compartments and other factors such as membrane permeability to water and restricted diffusion may be important (4,10,18).”
BackgroundSelf-citation
Cited by
Bennett, K. M., Schmainda, K. M., Bennett (Tong), R., Rowe, D. B., Lu, H., & Hyde, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10581 · Cited by 467
Özarslan, E., & Mareci, T. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10596 · Cited by 423
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305
Self-citationA Model for Diffusion in White Matter in the Brain
Sen, P. N., & Basser, P. J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.063016 · Cited by 266
Chatterjee, A., Watson, G., Myint, E., Sved, P., McEntee, M., & Bourne, R. (2015) · Radiology · doi:10.1148/radiol.2015142414 · Cited by 174
Metadata
- Authors
- Thelwall, P. E., Grant, S. C., Stanisz, G. J., & Blackband, S. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-09-26
- Volume
- 48
- Issue
- 4
- Pages
- 649-657
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2007162694
- Cited by
- 67
- References
- 2
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.