CoChat

Correlation between BOLD‐fMRI and EEG signal changes in response to visual stimulus frequency in humans

Open access
Singh, Manbir, Kim, Sungheon, Kim, Tae‐Seong · 2003 · Magnetic Resonance in Medicine
Cited by 112

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The correlation between signals acquired using electroencephalography (EEG) and fMRI was investigated in humans during visual stimulation. Evoked potential EEG and BOLD fMRI data were acquired independently under similar conditions from eight subjects during stimulation by a checkerboard flashed at frequencies ranging from 2–12 Hz. The results indicate highly correlated changes in the strength of the EEG signal averaged over two occipital electrodes and the BOLD signal within the occipital lobe as a function of flash frequency for 7/8 subjects (average linear correlation coefficient of 0.76). Both signals peaked at approximately 8 Hz. For one subject the correlation coefficient was 0.20; the EEG signal peaked at 6 Hz and the BOLD signal peaked at 10 Hz. Overall, the EEG and BOLD signals, each averaged over 40‐sec stimulation periods, appear to be coupled linearly during visual stimulation by a flashing checkerboard. Magn Reson Med 49:108–114, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10335

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 112

Metadata

Authors
Singh, M., Kim, S., & Kim, T.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-12-31
Volume
49
Issue
1
Pages
108-114
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1995287241
Cited by
112
References
3
FWCI
3.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.