The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Transmit SENSE
Abstract
The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially‐selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k‐space trajectory. Shortening this trajectory shortens the pulse duration. The use of multiple transmit coils, each with its own time‐dependent waveform and spatial sensitivity, can compensate for the missing parts of the excitation k‐space. This results in a maintained spatial definition of the pulse profile, while its duration is reduced. This work introduces the concept of parallel transmission with arbitrarily shaped transmit coils (termed “Transmit SENSE”). Results of numerical studies demonstrate the theoretical feasibility of the approach. The experimental proof of principle is provided on a commercial MR scanner. The lack of multiple independent transmit channels was addressed by combining the excitation patterns from two separate subexperiments with different transmit setups. Shortening multidimensional RF pulses could be an interesting means of making 3D RF pulses feasible even for fast T relaxing species or strong main field inhomogeneities. Other applications might benefit from the ability of Transmit SENSE to improve the spatial resolution of the pulse profile while maintaining the transmit duration. Magn Reson Med 49:144–150, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Morelli, A. (2010) · AMS Campus - AlmaDL · Cited by 1,279
The Fourier transform and its applications
Hautus, M. L. J. (1980) · European Journal of Operational Research · doi:10.1016/0377-2217(80)90120-4 · Cited by 1,144
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Self-citationDensity compensation functions for spiral MRI
Hoge, R. D., Kwan, R. K. S., & Pike, G. B. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380117 · Cited by 129
Cited by
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221
Metadata
- Authors
- Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-12-31
- Volume
- 49
- Issue
- 1
- Pages
- 144-150
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2604996334
- Cited by
- 719
- References
- 6
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transmit SENSE. https://app.cochat.ai/papers/10.1002/mrm.10353
- The paper
- Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003). Transmit SENSE. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.