Cited by 246Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsNMR spectroscopy and applications

Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain

Does, Mark D., Parsons, Edward C., Gore, John C.·2003·Magnetic Resonance in Medicine

Abstract

Oscillating gradients were used to probe the diffusion-time/frequency dependence of water diffusion in the gray matter of normal and globally ischemic rat brain. In terms of a conventional definition of diffusion time, the oscillating gradient measurements provided the apparent diffusion coefficient (ADC) of water with diffusion times between 9.75 ms and 375 micros, an order of magnitude shorter than previously studied in vivo. Over this range, ADCs increased as much as 24% in vivo and 50% postmortem, depending on the nature of the oscillating gradient waveform used. Novel waveforms were employed to sample narrow frequency bands of the so-called diffusion spectrum. This spectral description of ADC includes the effects of restriction and/or flow, and is independent of experimental parameters, such as diffusion time. The results in rat brain were found to be consistent with restricted diffusion and the known micro-anatomy of gray matter. Differences between normal and postmortem data were consistent with an increase in water restriction and/or a decrease in flow, and tentatively suggest that physical changes following the onset of ischemia occur on a scale of about 2 microm, similar to a typical cellular dimension in gray matter.

Integrity signals

Registry

Crossref · 10.1002/mrm.10385

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Stronger gradients and dedicated diffusion-MRI sequences such as oscillating-gradient spin echo (OGSE) permit shorter diffusion times and reveal additional tissue-specific information through diffusion-time-dependent water behavior.

    “Today, stronger gradients and dedicated diffusion-MRI sequences, such as oscillating-gradient spin echo (OGSE), permit shorter diffusion times and reveal additional tissue-specific information through diffusion-time-dependent water behavior (Does et al., 2003; Zhu et al., 2025).”

    From 40 Years of diffusion MRI in the brain: From history to emerging frontiers (2026) · cites this paper as Does et al., 2003

Cited by

Sorted by citations

Authors
Does, M. D., Parsons, E. C., & Gore, J. C.
Affiliations
Yale University (US)
Corresponding author
Does, Mark D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-01-22
Volume
49
Issue
2
Pages
206-215
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2041626473
Cited by
246
References
0
Citations by year
2026: 11 · 2025: 20 · 2024: 9 · 2023: 24 · 2022: 15 · 2021: 12 · 2020: 17 · 2019: 19 · 2018: 18 · 2017: 10 · 2016: 14 · 2015: 10 · 2014: 13 · 2013: 10 · 2012: 6
FWCI
1.61
Type
journal article
Language
en
Open access
closed
Locations
  • Magnetic Resonance in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Cancer Institute (CA40675, R01CA040675)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
water diffusion, apparent diffusion coefficient, global cerebral ischemia, gray matter, restricted diffusion, diffusion time dependence, postmortem changes, rat brain
MeSH terms
Animals, Body Water, Brain, Brain Ischemia, Diffusion, Postmortem Changes, Rats, Sprague-Dawley, Diffusion Magnetic Resonance Imaging, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review