Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Patlak plots of Gd‐DTPA MRI data yield blood–brain transfer constants concordant with those of 14C‐sucrose in areas of blood–brain opening

Open access
Ewing, James R., Knight, Robert A., Nagaraja, Tavarekere N., Yee, John S., Nagesh, Vijaya, Whitton, Polly A., Li, Lian, Fenstermacher, Joseph D.·2003·Magnetic Resonance in Medicine

Abstract

The blood‐to‐brain transfer rate constant (K i) of Gd‐DTPA was determined in MRI studies of a rat model of transient cerebral ischemia. The longitudinal relaxation rate, R 1, was estimated using repeated Look‐Locker measurements. A model‐independent analysis of ΔR 1, the Patlak plot, produced maps of K i for Gd‐DTPA and the distribution volume of the mobile protons (V p) with intravascular‐Gd changed R 1's. The K i's of Gd‐DTPA were estimated in regions of interest with blood–brain barrier (BBB) opening (regions of interest, ROIs) and compared to those of 14 C‐sucrose determined shortly thereafter by quantitative autoradiography. The K i's for both Gd‐DTPA and sucrose were much higher than normal within the ROIs (n = 7); linear regression of K i for Gd‐DTPA vs. K i for sucrose yielded a slope of 0.43 ± 0.11 and r 2 = 0.72 (P = 0.01). Thus, K i for Gd‐DTPA varied in parallel with, but was less than, K i for sucrose. In the ROIs, mean V p was 0.071 ml g−1 and much higher than mean vascular volume estimated by dynamic‐contrast‐enhancement (0.013 ml g−1) or mean V p in contralateral brain (0.015 ml g−1). This elevated V p may reflect increased capillary permeability to water. In conclusion, K i can be reliably calculated from Gd‐DTPA‐MRI data by Patlak plots. Magn Reson Med 50:283–292, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10524

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 181

Metadata

Authors
Ewing, J. R., Knight, R. A., Nagaraja, T. N., Yee, J. S., Nagesh, V., Whitton, P. A., Li, L., & Fenstermacher, J. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-07-17
Volume
50
Issue
2
Pages
283-292
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1979482187
Cited by
181
References
3
FWCI
6.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patlak plots of Gd‐DTPA MRI data yield blood–brain transfer constants concordant with those of 14C‐sucrose in areas of blood–brain opening. https://app.cochat.ai/papers/10.1002/mrm.10524
The paper
Ewing, J. R., Knight, R. A., Nagaraja, T. N., Yee, J. S., Nagesh, V., Whitton, P. A., Li, L., & Fenstermacher, J. D. (2003). Patlak plots of Gd‐DTPA MRI data yield blood–brain transfer constants concordant with those of 14C‐sucrose in areas of blood–brain opening. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10524

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.