The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved molecular imaging contrast agent for detection of human thrombus
Open accessAbstract
Molecular imaging of microthrombus within fissures of unstable atherosclerotic plaques requires sensitive detection with a thrombus‐specific agent. Effective molecular imaging has been previously demonstrated with fibrin‐targeted Gd‐DTPA‐bis‐oleate (BOA) nanoparticles. In this study, the relaxivity of an improved fibrin‐targeted paramagnetic formulation, Gd‐DTPA‐phosphatidylethanolamine (PE), was compared with Gd‐DTPA‐BOA at 0.05‐4.7 T. Ion‐ and particle‐based r 1 relaxivities (1.5 T) for Gd‐DTPA‐PE (33.7 (s*mM)‐1 and 2.48 × 10 6 (s*mM)‐1, respectively) were about twofold higher than for Gd‐DTPA‐BOA, perhaps due to faster water exchange with surface gadolinium. Gd‐DTPA‐PE nanoparticles bound to thrombus surfaces via anti‐fibrin antibodies (1H10) induced 72% ± 5% higher change in R1 values at 1.5 T (Δ R1 = 0.77 ± 0.02 1/s) relative to Gd‐DTPA‐BOA (Δ R1 = 0.45 ± 0.02 1/s). These studies demonstrate marked improvement in a fibrin‐specific molecular imaging agent that might allow sensitive, early detection of vascular microthrombi, the antecedent to stroke and heart attack. Magn Reson Med 50:411–416, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Self-citation
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Self-citationLanthanides in magnetic resonance imaging
Bottrill, M., Kwok, L., & Long, N. J. (2006) · Chemical Society Reviews · doi:10.1039/b516376p · Cited by 583
Winter, P. M., Neubauer, A. M., Caruthers, S. D., Harris, T. D., Robertson, J. D., Williams, T. A., Schmieder, A. H., Hu, G., Allen, J. S., Lacy, E. K., et al. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000235724.11299.76 · Cited by 379
Self-citation
Metadata
- Authors
- Winter, P. M., Caruthers, S. D., Yu, X., Song, S., Chen, J., Miller, B., Bulte, J. W. M., Robertson, J. D., Gaffney, P. J., Wickline, S. A., & Lanza, G. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-07-17
- Volume
- 50
- Issue
- 2
- Pages
- 411-416
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2107222316
- Cited by
- 189
- References
- 1
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved molecular imaging contrast agent for detection of human thrombus. https://app.cochat.ai/papers/10.1002/mrm.10532
- The paper
- Winter, P. M., Caruthers, S. D., Yu, X., Song, S., Chen, J., Miller, B., Bulte, J. W. M., Robertson, J. D., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2003). Improved molecular imaging contrast agent for detection of human thrombus. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10532
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.